Literature DB >> 23648397

Simultaneous reconstruction of emission activity and attenuation coefficient distribution from TOF data, acquired with external transmission source.

V Y Panin1, M Aykac, M E Casey.   

Abstract

The simultaneous PET data reconstruction of emission activity and attenuation coefficient distribution is presented, where the attenuation image is constrained by exploiting an external transmission source. Data are acquired in time-of-flight (TOF) mode, allowing in principle for separation of emission and transmission data. Nevertheless, here all data are reconstructed at once, eliminating the need to trace the position of the transmission source in sinogram space. Contamination of emission data by the transmission source and vice versa is naturally modeled. Attenuated emission activity data also provide additional information about object attenuation coefficient values. The algorithm alternates between attenuation and emission activity image updates. We also proposed a method of estimation of spatial scatter distribution from the transmission source by incorporating knowledge about the expected range of attenuation map values. The reconstruction of experimental data from the Siemens mCT scanner suggests that simultaneous reconstruction improves attenuation map image quality, as compared to when data are separated. In the presented example, the attenuation map image noise was reduced and non-uniformity artifacts that occurred due to scatter estimation were suppressed. On the other hand, the use of transmission data stabilizes attenuation coefficient distribution reconstruction from TOF emission data alone. The example of improving emission images by refining a CT-based patient attenuation map is presented, revealing potential benefits of simultaneous CT and PET data reconstruction.

Entities:  

Mesh:

Year:  2013        PMID: 23648397     DOI: 10.1088/0031-9155/58/11/3649

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Joint Reconstruction of Activity and Attenuation in Time-of-Flight PET: A Quantitative Analysis.

Authors:  Ahmadreza Rezaei; Christophe M Deroose; Thomas Vahle; Fernando Boada; Johan Nuyts
Journal:  J Nucl Med       Date:  2018-03-01       Impact factor: 10.057

3.  Respiratory Motion Compensation for PET/CT with Motion Information Derived from Matched Attenuation-Corrected Gated PET Data.

Authors:  Yihuan Lu; Kathryn Fontaine; Tim Mulnix; John A Onofrey; Silin Ren; Vladimir Panin; Judson Jones; Michael E Casey; Robert Barnett; Peter Kench; Roger Fulton; Richard E Carson; Chi Liu
Journal:  J Nucl Med       Date:  2018-02-09       Impact factor: 10.057

Review 4.  Principles of Simultaneous PET/MR Imaging.

Authors:  Ciprian Catana
Journal:  Magn Reson Imaging Clin N Am       Date:  2017-05       Impact factor: 2.266

Review 5.  Advances in time-of-flight PET.

Authors:  Suleman Surti; Joel S Karp
Journal:  Phys Med       Date:  2016-01-06       Impact factor: 2.685

6.  Transmission-less attenuation estimation from time-of-flight PET histo-images using consistency equations.

Authors:  Yusheng Li; Michel Defrise; Scott D Metzler; Samuel Matej
Journal:  Phys Med Biol       Date:  2015-08-12       Impact factor: 3.609

7.  Transmission imaging for integrated PET-MR systems.

Authors:  Spencer L Bowen; Niccolò Fuin; Michael A Levine; Ciprian Catana
Journal:  Phys Med Biol       Date:  2016-07-06       Impact factor: 3.609

8.  PET-enabled dual-energy CT: image reconstruction and a proof-of-concept computer simulation study.

Authors:  Guobao Wang
Journal:  Phys Med Biol       Date:  2020-12-17       Impact factor: 3.609

9.  Modified kernel MLAA using autoencoder for PET-enabled dual-energy CT.

Authors:  Siqi Li; Guobao Wang
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2021-07-05       Impact factor: 4.019

10.  Deep learning-based attenuation correction for whole-body PET - a multi-tracer study with 18F-FDG, 68 Ga-DOTATATE, and 18F-Fluciclovine.

Authors:  Takuya Toyonaga; Dan Shao; Luyao Shi; Jiazhen Zhang; Enette Mae Revilla; David Menard; Joseph Ankrah; Kenji Hirata; Ming-Kai Chen; John A Onofrey; Yihuan Lu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-03-12       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.