Literature DB >> 23645385

MRI-guided percutaneous coaxial cutting needle biopsy of small pulmonary nodules: feasibility.

Ming Liu1, Yubo Lv, Lebin Wu, Jiqing Song, Roberto Blanco Sequeiros, Chengli Li.   

Abstract

OBJECTIVES: To prospectively evaluate the feasibility, safety and accuracy of magnetic resonance imaging (MRI)-guided percutaneous coaxial cutting needle biopsy of small (≤2.0 cm in diameter) pulmonary nodules.
METHODS: Ninety-six patients (56 men and 40 women) with 96 small lung nodules underwent MRI-guided percutaneous coaxial cutting needle biopsy. These lesions were divided into two groups according to maximum nodule diameters: 0.5-1.0 cm (n = 25) and 1.1-2.0 cm (n = 71). The diagnostic accuracy, sensitivity and specificity were calculated, and comparison of the two groups was performed using Fisher's exact test.
RESULTS: All specimens obtained were sufficient for diagnosis. Histological examination of needle biopsy revealed 64 malignant, 30 benign and 2 indeterminate nodules. The final diagnoses from surgery or clinical follow-up were 67 malignant nodules and 29 benign nodules. The diagnostic performance of MRI-guided percutaneous coaxial cutting needle biopsy in diagnosing malignant tumours was as follows: accuracy, 97 %; sensitivity, 96 %; specificity, 100 %; positive predictive value, 100 %; and negative predictive value, 91 %. There was no significant difference between the two groups (P > 0.05, Fisher's exact test). No serious complications occurred.
CONCLUSIONS: MRI-guided percutaneous coaxial cutting needle biopsy is a safe and accurate diagnostic technique in the evaluation of small lung nodules. KEY POINTS: • MRI-guided biopsy helps clinicians to assess patients with small lung nodules. • Differentiation of malignant and benign nodules is possible with 97 % accuracy. • MRI guidance enables accurate lung biopsy without ionising radiation. • No serious complications occurred in MRI-guided lung biopsy.

Entities:  

Mesh:

Year:  2013        PMID: 23645385     DOI: 10.1007/s00330-013-2871-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  33 in total

1.  CT-guided needle biopsy of small pulmonary nodules: value of respiratory gating.

Authors:  N Tomiyama; N Mihara; M Maeda; T Johkoh; T Kozuka; O Honda; S Hamada; S Yoshida; H Nakamura
Journal:  Radiology       Date:  2000-12       Impact factor: 11.105

2.  Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules?

Authors:  Takuji Yamagami; Shigeharu Iida; Takeharu Kato; Osamu Tanaka; Tsunehiko Nishimura
Journal:  AJR Am J Roentgenol       Date:  2003-03       Impact factor: 3.959

3.  CT fluoroscopy-guided percutaneous needle biopsies in thoracic mass lesions.

Authors:  Emir Silit; Esref Kizilkaya; Oguzhan Okutan; Zekai Pekkafali; Hakan Mutlu; C Cinar Basekim; A Fevzi Karsli
Journal:  Eur J Radiol       Date:  2003-11       Impact factor: 3.528

4.  MR fluoroscopy-guided transthoracic fine-needle aspiration biopsy: feasibility.

Authors:  Mehmet Emin Sakarya; Ozkan Unal; Bulent Ozbay; Kursat Uzun; Ismail Kati; Suleyman Ozen; Omer Etlik
Journal:  Radiology       Date:  2003-06-20       Impact factor: 11.105

5.  Transthoracic needle biopsy of lung masses: a survey of techniques.

Authors:  G Aviram; D S Schwartz; S Meirsdorf; G Rosen; J Greif; M Graif
Journal:  Clin Radiol       Date:  2005-03       Impact factor: 2.350

6.  CT-guided interventional procedures without CT fluoroscopy assistance: patient effective dose and absorbed dose considerations.

Authors:  Ioannis A Tsalafoutas; Virginia Tsapaki; Charicleia Triantopoulou; Akrivi Gorantonaki; John Papailiou
Journal:  AJR Am J Roentgenol       Date:  2007-06       Impact factor: 3.959

Review 7.  Technical aspects of needle aspiration lung biopsy: a personal perspective.

Authors:  E H Moore
Journal:  Radiology       Date:  1998-08       Impact factor: 11.105

8.  Percutaneous magnetic resonance image-guided biopsy and aspiration in the head and neck.

Authors:  E M Merkle; J S Lewin; A J Aschoff; D W Stepnick; J L Duerk; C F Lanzieri; M Strauss
Journal:  Laryngoscope       Date:  2000-03       Impact factor: 3.325

9.  Evaluation of patient and staff doses during various CT fluoroscopy guided interventions.

Authors:  Nico Buls; Jessica Pagés; Johan de Mey; Michel Osteaux
Journal:  Health Phys       Date:  2003-08       Impact factor: 1.316

10.  CT-guided fine-needle aspirations for diagnosis of benign and malignant disease.

Authors:  L P Harter; A A Moss; H I Goldberg; B H Gross
Journal:  AJR Am J Roentgenol       Date:  1983-02       Impact factor: 3.959

View more
  1 in total

1.  Functional imaging with diffusion-weighted MRI for lung biopsy planning: initial experience.

Authors:  Marcos D Guimaraes; Edson Marchiori; Bruno C Odisio; Bruno Hochhegger; Almir G V Bitencourt; Charles E Zurstrassen; Chiang C Tyng; Jefferson L Gross; Rubens Chojniak; Myrna C B Godoy
Journal:  World J Surg Oncol       Date:  2014-07-10       Impact factor: 2.754

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.