Literature DB >> 23645205

Phonographic signal with a fractional-order chaotic system: a novel and simple algorithm for analyzing residual arteriovenous access stenosis.

Wei-Ling Chen1, Tainsong Chen, Chia-Hung Lin, Pei-Jarn Chen, Chung-Dann Kan.   

Abstract

To detect the early developmental stages of arteriovenous access (AVA) stenosis in hemodialysis patients, this study explored a stenosis detector based on the Burg method and the fractional-order chaos system (FOCS). The bruit developed by the blood flowing through AVA can be a viable noninvasive strategy for monitoring AVA functions. We used the Burg method of the autoregressive model to estimate the frequency spectra of phonographic signals recorded by an electronic stethoscope in patients' AVAs and to identify the spectral peaks in the region of 25-800 Hz. The frequency spectra differed significantly between normal and stenosis statuses in AVA. We found that the frequency and amplitude in power spectra analysis varied in accordance with the severity of AVA stenosis. However, the correlation of these parameters for classifying the degree of stenosis is limited when only using the Burg method. Therefore, we used an FOCS to monitor the differing frequency spectra between the normal condition and AVA stenosis. The variances of these two conditions were dynamic errors that were the coupling variables that tracked the responses between the master system and the slave system. A total of 42 patients who had received percutaneous transluminal angioplasty (PTA) for their failing AVAs was recruited for this study. In this study, the dynamic error, Index Ψ, was used to calculate the frequency spectrum redistribution in patients undergoing PTA. In addition, ΔImp was the index used to evaluate improvements in the luminal diameter between pre- and post-PTA. Therefore, we used linear regression to model the relationship between ΔImp and Index Ψ. The findings indicate that the proposed method has enhanced efficiency, especially in the venous anastomosis (V-site). The FOCS is a novel and simple algorithm for analyzing the residual AVA stenosis of PTA treatment.

Entities:  

Mesh:

Year:  2013        PMID: 23645205     DOI: 10.1007/s11517-013-1077-y

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  11 in total

1.  Influence of stenosis morphology on flow through severely stenotic vessels: implications for plaque rupture.

Authors:  J S Stroud; S A Berger; D Saloner
Journal:  J Biomech       Date:  2000-04       Impact factor: 2.712

2.  Application of the ARMA method to acoustic detection of coronary artery disease.

Authors:  M Akay; W Welkowitz; J L Semmlow; J Kostis
Journal:  Med Biol Eng Comput       Date:  1991-07       Impact factor: 2.602

3.  Prevalence and risk factors for CKD in spouses and relatives of hemodialysis patients.

Authors:  Jer-Chia Tsai; Szu-Chia Chen; Shang-Jyh Hwang; Jer-Ming Chang; Ming-Yen Lin; Hung-Chun Chen
Journal:  Am J Kidney Dis       Date:  2010-02-13       Impact factor: 8.860

4.  Short- and long-term functional effects of percutaneous transluminal angioplasty in hemodialysis vascular access.

Authors:  Joke van der Linden; Johannes H M Smits; Jan H Assink; Derk W Wolterbeek; Jan J Zijlstra; Gijs H T de Jong; Marinus A van den Dorpel; Peter J Blankestijn
Journal:  J Am Soc Nephrol       Date:  2002-03       Impact factor: 10.121

5.  Arteriovenous fistula stenosis detection using wavelets and support vector machines.

Authors:  Pablo O Vesquez; Munguia M Marco; Bengt Mandersson
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

6.  Dialysis access venous stenoses: treatment with balloon angioplasty--1- versus 3-minute inflation times.

Authors:  Andrew R Forauer; Eric K Hoffer; Karen Homa
Journal:  Radiology       Date:  2008-10       Impact factor: 11.105

7.  Beneficial effects of banding on venous intimal-medial hyperplasia in arteriovenous loop grafts.

Authors:  M F Fillinger; E R Reinitz; R A Schwartz; D E Resetarits; A M Paskanik; C E Bredenberg
Journal:  Am J Surg       Date:  1989-08       Impact factor: 2.565

Review 8.  Hemodialysis vascular access monitoring: current concepts.

Authors:  Michael Allon; Michelle L Robbin
Journal:  Hemodial Int       Date:  2009-04       Impact factor: 1.812

9.  Noninvasive acoustical detection of coronary artery disease: a comparative study of signal processing methods.

Authors:  Y M Akay; M Akay; W Welkowitz; J L Semmlow; J B Kostis
Journal:  IEEE Trans Biomed Eng       Date:  1993-06       Impact factor: 4.538

10.  Surveillance and monitoring of dialysis access.

Authors:  Lalathaksha Kumbar; Jariatul Karim; Anatole Besarab
Journal:  Int J Nephrol       Date:  2011-11-22
View more
  5 in total

1.  Hemodialysis vascular access stenosis detection using auditory spectro-temporal features of phonoangiography.

Authors:  Po-Hsun Sung; Chung-Dann Kan; Wei-Ling Chen; Ling-Sheng Jang; Jhing-Fa Wang
Journal:  Med Biol Eng Comput       Date:  2015-02-15       Impact factor: 2.602

2.  Flexible, Skin Coupled Microphone Array for Point of Care Vascular Access Monitoring.

Authors:  Binit Panda; Soumyajit Mandal; Steve J A Majerus
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-10-18       Impact factor: 3.833

3.  Bilateral photoplethysmography for arterial steal detection in arteriovenous fistula using a fractional-order decision-making quantizer.

Authors:  Jian-Xing Wu; Guan-Chun Chen; Ming-Jui Wu; Chia-Hung Lin; Tainsong Chen
Journal:  Med Biol Eng Comput       Date:  2016-05-06       Impact factor: 2.602

4.  Parameter Identification of Fractional-Order Discrete Chaotic Systems.

Authors:  Yuexi Peng; Kehui Sun; Shaobo He; Dong Peng
Journal:  Entropy (Basel)       Date:  2019-01-01       Impact factor: 2.524

5.  Multiple-site hemodynamic analysis of Doppler ultrasound with an adaptive color relation classifier for arteriovenous access occlusion evaluation.

Authors:  Jian-Xing Wu; Yi-Chun Du; Ming-Jui Wu; Chien-Ming Li; Chia-Hung Lin; Tainsong Chen
Journal:  ScientificWorldJournal       Date:  2014-04-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.