Literature DB >> 23645162

Impact of machines on plan quality: volumetric modulated arc therapy and intensity modulated radiation therapy.

S Clemente1, M Cozzolino, C Oliviero, A Fiorentino, C Chiumento, V Fusco.   

Abstract

PURPOSE: To evaluate the impact of different machines on plan quality using both intensity modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques.
MATERIALS AND METHODS: Eight patients with squamous cell carcinoma of the oropharynx were selected at random. Plans were computed for IMRT and VMAT Smart Arc, using Pinnacle TPS for an Elekta (IMRT-E, VMAT-E) and Varian linac (IMRT-V, VMAT-V). A three-dose level prescription was used to deliver 70, 63 and 58.1 Gy to regions of macroscopic, microscopic high- and low-risk disease, respectively. All doses were given in 35 fractions. Comparisons were performed on dose-volume histogram data, monitor units (MU), and delivery time.
RESULTS: VMAT-E plans resulted slightly MU efficient (-24 % p < 0.05) compared to VMAT-V while IMRT-V shortened delivery time (-19 % p < 0.05) compared to IMRT-E. All the delivery techniques resulted in equivalent target coverage in terms of D(98) % and D(2) %. For VMAT technique, a significant improvement of 7 % in homogeneity index (HI) for PTV58.1 was observed for Varian machine. A slight improvement in OARs sparing was observed with Elekta machine both for IMRT and VMAT techniques.
CONCLUSION: Similar plan quality was observed for Elekta and Varian linacs, significant differences were observed in delivery efficiency, as MU number and delivery times, in favor of Elekta and Varian, respectively.

Entities:  

Mesh:

Year:  2013        PMID: 23645162     DOI: 10.1007/s12094-013-1049-6

Source DB:  PubMed          Journal:  Clin Transl Oncol        ISSN: 1699-048X            Impact factor:   3.405


  20 in total

1.  The potential for sparing of parotids and escalation of biologically effective dose with intensity-modulated radiation treatments of head and neck cancers: a treatment design study.

Authors:  Q Wu; M Manning; R Schmidt-Ullrich; R Mohan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-01-01       Impact factor: 7.038

2.  Comparison of total MU and segment areas in VMAT and step-and-shoot IMRT plans.

Authors:  Motohiro Kawashima; Shuichi Ozawa; Akihiro Haga; Akira Sakumi; Chie Kurokawa; Satoru Sugimoto; Kumiko Karasawa; Keiichi Nakagawa; Keisuke Sasai
Journal:  Radiol Phys Technol       Date:  2012-07-01

3.  Is there a "mucosa-sparing" benefit of IMRT for head-and-neck cancer?

Authors:  Giuseppe Sanguineti; Eugene J Endres; Brandon G Gunn; Brent Parker
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-11-01       Impact factor: 7.038

4.  Volumetric modulated arc therapy: IMRT in a single gantry arc.

Authors:  Karl Otto
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

5.  Volumetric modulated arc radiotherapy for carcinomas of the oro-pharynx, hypo-pharynx and larynx: a treatment planning comparison with fixed field IMRT.

Authors:  Eugenio Vanetti; Alessandro Clivio; Giorgia Nicolini; Antonella Fogliata; Sarbani Ghosh-Laskar; Jai Prakash Agarwal; Ritu Raj Upreti; Ashwini Budrukkar; Vedang Murthy; Deepak Dattatray Deshpande; Shyam Kishore Shrivastava; Ketayun Ardeshir Dinshaw; Luca Cozzi
Journal:  Radiother Oncol       Date:  2009-01-20       Impact factor: 6.280

6.  Volumetric-modulated arc therapy in head and neck radiotherapy: a planning comparison using simultaneous integrated boost for nasopharynx and oropharynx carcinoma.

Authors:  M Johnston; S Clifford; R Bromley; M Back; L Oliver; T Eade
Journal:  Clin Oncol (R Coll Radiol)       Date:  2011-03-11       Impact factor: 4.126

7.  Intensity modulation with photons for benign intracranial tumours: a planning comparison of volumetric single arc, helical arc and fixed gantry techniques.

Authors:  Antonella Fogliata; Alessandro Clivio; Giorgia Nicolini; Eugenio Vanetti; Luca Cozzi
Journal:  Radiother Oncol       Date:  2008-08-28       Impact factor: 6.280

Review 8.  Radiation-induced second cancers: the impact of 3D-CRT and IMRT.

Authors:  Eric J Hall; Cheng-Shie Wuu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-05-01       Impact factor: 7.038

9.  Volumetric intensity-modulated arc therapy vs. conventional IMRT in head-and-neck cancer: a comparative planning and dosimetric study.

Authors:  Wilko F A R Verbakel; Johan P Cuijpers; Daan Hoffmans; Michael Bieker; Ben J Slotman; Suresh Senan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-05-01       Impact factor: 7.038

10.  Dosimetric effect of multileaf collimator leaf width in intensity-modulated radiotherapy delivery techniques for small- and large-volume targets.

Authors:  S A Yoganathan; Karthick Raj Mani; K J Maria Das; Arpita Agarwal; Shaleen Kumar
Journal:  J Med Phys       Date:  2011-04
View more
  1 in total

1.  Influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning.

Authors:  Motoharu Sasaki; Masahide Tominaga; Takeshi Kamomae; Hitoshi Ikushima; Motonori Kitaoka; Ryota Bando; Kanako Sakuragawa; Masataka Oita
Journal:  Jpn J Radiol       Date:  2017-06-24       Impact factor: 2.374

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.