Literature DB >> 23644542

The sheeping technique or how to avoid exchange maneuvers.

René Chapot1, Hannes Nordmeyer2, Markus Heddier2, Aglaé Velasco2, Petra Schooss2, Michael Stauder2, Paul Stracke2, Pascal J Mosimann2,3.   

Abstract

INTRODUCTION: The arteries of bifurcation aneurysms are sometimes so angulated or tortuous that an exchange maneuver is necessary to catheterize them with a balloon or stent delivery catheter. Because of the risk of distal wire perforation associated with exchange maneuvers, we sought to find an alternative technique.
METHODS: Our experience shows that a microcatheter tends to preferentially follow a previously placed microcatheter, even if the initial catheterization might be challenging. Accessing an artery with two microcatheters simultaneously may thus be an alternative to an exchange maneuver. Because of this tendency for catheters to behave like sheep following one another, we named this method the sheeping technique (ST). The ST consists of (a) first placing a 1.7 French microcatheter into the division branch requiring balloon or stent protection to straighten the course of the arteries in order to facilitate and (b) positioning in the same artery of a larger and stiffer balloon or stent microcatheter. Once the second balloon or stent microcatheter is in place, the first microcatheter can be pulled back and used to coil the aneurysm.
RESULTS: Between January 2009 and December 2012, The ST was successfully used in 208/246 procedures (85%). Conversion to an exchange maneuver was necessary in 38/246 (15%). There were no arterial perforations or ischemic events related to the handling of both microcatheters.
CONCLUSION: The sheeping technique may improve safety by replacing the need for an exchange maneuver during difficult balloon- or stent-assisted coiling.

Entities:  

Mesh:

Year:  2013        PMID: 23644542     DOI: 10.1007/s00234-013-1197-y

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  9 in total

1.  The effect of intracranial stent implantation on the curvature of the cerebrovasculature.

Authors:  R M King; J-Y Chueh; I M J van der Bom; C F Silva; S L Carniato; G Spilberg; A K Wakhloo; M J Gounis
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-26       Impact factor: 3.825

2.  Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: a single-center experience.

Authors:  Sergin Akpek; Anil Arat; Hesham Morsi; Richard P Klucznick; Charles M Strother; Michel E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

3.  Waffle-cone technique with Solitaire™ AB remodeling device: endovascular treatment of highly selected complex cerebral aneurysms.

Authors:  Vojtech Sychra; Joachim Klisch; Maren Werner; Christian Dettenborn; Alexander Petrovitch; Christoph Strasilla; Rüdiger Gerlach; Steffen Rosahl; Markus Holtmannspötter
Journal:  Neuroradiology       Date:  2010-09-07       Impact factor: 2.804

4.  Long-term clinical and angiographic results of Neuroform stent-assisted coil embolization in wide-necked intracranial aneurysms.

Authors:  Alejandro Santillan; Edward Greenberg; Athos Patsalides; Kimberly Salvaggio; Howard A Riina; Y Pierre Gobin
Journal:  Neurosurgery       Date:  2012-05       Impact factor: 4.654

5.  Intra/extra-aneurysmal stent placement for management of complex and wide-necked- bifurcation aneurysms: eight cases using the waffle cone technique.

Authors:  Michael Horowitz; Elad Levy; Eric Sauvageau; Julie Genevro; Lee R Guterman; Ricardo Hanel; Christopher Wehman; Rishi Gupta; Tudor Jovin
Journal:  Neurosurgery       Date:  2006-04       Impact factor: 4.654

6.  Stent-assisted coiling of intracranial aneurysms: clinical and angiographic results in 216 consecutive aneurysms.

Authors:  Michel Piotin; Raphaël Blanc; Laurent Spelle; Charbel Mounayer; Rhelen Piantino; Paul J Schmidt; Jacques Moret
Journal:  Stroke       Date:  2009-12-03       Impact factor: 7.914

7.  Intracranial hemorrhage associated with stent-assisted coil embolization of cerebral aneurysms: a cautionary report.

Authors:  Luis M Tumialán; Y Jonathan Zhang; C Michael Cawley; Jacques E Dion; Frank C Tong; Daniel L Barrow
Journal:  J Neurosurg       Date:  2008-06       Impact factor: 5.115

8.  Monitoring of clopidogrel-related platelet inhibition: correlation of nonresponse with clinical outcome in supra-aortic stenting.

Authors:  S Müller-Schunk; J Linn; N Peters; M Spannagl; M Deisenberg; H Brückmann; T E Mayer
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-25       Impact factor: 3.825

9.  HyperForm balloon-assisted endovascular neck bypass technique to perform balloon or stent-assisted treatment of cerebral aneurysms.

Authors:  S H Cekirge; K Yavuz; S Geyik; I Saatci
Journal:  AJNR Am J Neuroradiol       Date:  2007-08       Impact factor: 3.825

  9 in total
  8 in total

1.  S-shaped distal access catheter supported microcatheter navigation into the lenticulostriate artery feeders of brain arteriovenous malformations.

Authors:  Satoshi Koizumi; Masaaki Shojima; Osamu Ishikawa; Hirotaka Hasegawa; Satoru Miyawaki; Hirofumi Nakatomi; Nobuhito Saito
Journal:  Interv Neuroradiol       Date:  2020-06-19       Impact factor: 1.610

2.  The "temporary caging" technique for catheter navigation in patients with intracranial wide-necked aneurysms.

Authors:  Hidemichi Ito; Hidetaka Onodera; Daisuke Wakui; Masashi Uchida; Taigen Sase; Hiroyuki Morishima; Kotaro Oshio; Yuichiro Tanaka
Journal:  Int J Clin Exp Med       Date:  2015-07-15

3.  Flow diversion beyond the circle of Willis: endovascular aneurysm treatment in peripheral cerebral arteries employing a novel low-profile flow diverting stent.

Authors:  Karl-Titus Hoffmann; Jürgen Meixensberger; Ulf Quäschling; Stefan Schob; Cindy Richter; Pervinder Bhogal; Katharina Köhlert; Uwe Planitzer; Svitlana Ziganshyna; Dirk Lindner; Cordula Scherlach; Ulf Nestler
Journal:  J Neurointerv Surg       Date:  2019-05-14       Impact factor: 5.836

4.  Carotid Artery Stenting Using the Snake Hunt Technique for Highly Tortuous Carotid Artery Stenosis: A Technical Note.

Authors:  Tomoki Koide; Yoshiro Ito; Tenyu Hino; Masayuki Sato; Aiki Marushima; Mikito Hayakawa; Yuji Matsumaru; Eiichi Ishikawa
Journal:  NMC Case Rep J       Date:  2021-07-09

5.  Kissing Aneurysms of the Posterior Inferior Cerebellar Artery Treated by Anchor Coil Technique and Stenting from the Contralateral Side: A Case Report.

Authors:  Tamon Ando; Tatsuya Ishikawa; Takayuki Funatsu; Koji Yamaguchi; Yosuke Moteki; Seiichiro Eguchi; Momo Uchida; Makiko Sakaguchi; Masahiko Nishitani; Takakazu Kawamata
Journal:  NMC Case Rep J       Date:  2022-08-26

6.  Delayed Rupture of an Anterior Communicating Artery Pseudoaneurysm Caused by Distal Occlusion Thrombectomy Using a Stent Retriever: A Case Report and Mechanism of Injury.

Authors:  Dong-Hyun Shim; Youngrok Do; Jin Kuk Do; Sung Won Youn
Journal:  Neurointervention       Date:  2022-05-10

7.  Balloon-Assistance for the Transcirculation Access of a Remodeling Balloon for Coiling of Wide-Necked Aneurysms: Report of Two Cases.

Authors:  Madan Mohan Balaguruswamy; Ezaz Mohamed; Krishnan Vijayan; Chaitanya S Juluri; Karuppannaswamy Madeswaran
Journal:  Neurointervention       Date:  2021-05-21

8.  Flow diversion in challenging vascular anatomies: the use of low profile stent retrievers for safe and accurate positioning of the microcatheter.

Authors:  Ulf Quäschling; Monika Kläver; Cindy Richter; Gordian Hamerla; Simone Mucha; Cordula Scherlach; Jens Maybaum; Karl-Titus Hoffmann; Stefan Schob
Journal:  CVIR Endovasc       Date:  2020-03-30
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.