Literature DB >> 23635279

Respiration-based sorting of dynamic MRI to derive representative 4D-MRI for radiotherapy planning.

Erik Tryggestad1, Aaron Flammang, Sarah Han-Oh, Russell Hales, Joseph Herman, Todd McNutt, Teboh Roland, Steven M Shea, John Wong.   

Abstract

PURPOSE: Current pretreatment, 4D imaging techniques are suboptimal in that they sample breathing motion over a very limited "snap-shot" in time. To potentially address this, the authors have developed a longer-duration MRI and postprocessing technique to derive the average or most-probable state of mobile anatomy and meanwhile capture and convey the observed motion variability.
METHODS: Sagittal and coronal multislice, 2D dynamic MRI was acquired in a sequential fashion over extended durations in two abdominal and four lung studies involving healthy volunteers. Two sequences, readily available on a commercial system, were employed. Respiratory interval-correlated, or 4D-MRI, volumes were retrospectively derived using a two-pass approach. In a first pass, a respiratory trace acquired simultaneous with imaging was processed and slice stacking was used to derive a set of MRI volumes, each representing an equal time or proportion of respiration. Herein, all raw 2D frames mapping to the given respiratory interval, per slice location, were averaged. In a second-pass, this prior reconstruction provided a set of template images and a similarity metric was employed to discern the subset of best-matching raw 2D frames for secondary averaging (per slice location and respiratory interval). Breathing variability (per respiratory interval and slice location) was depicted by computing both a maximum intensity projection as well as a pixelwise standard deviation image.
RESULTS: These methods were successfully demonstrated in both the lung and abdomen for both applicable sequences, performing reconstructions with ten respiratory intervals. The first-pass (average) resulted in motion-induced blurring, especially for irregular breathing. The authors have demonstrated qualitatively that the second-pass result can mitigate this blurring.
CONCLUSIONS: They have presented a novel methodology employing dMRI to derive representative 4D-MRI. This set of techniques are practical in that (1) they employ MRI sequences that are standard across commercial vendors; (2) the 2D imaging planes can be oriented onto an arbitrary axis (e.g., sagittal, coronal, axial[ellipsis (horizontal)]); (3) the image processing techniques are relatively simple. Systematically applying this and similar dMRI-based techniques in patients is a crucial next step to demonstrate efficacy beyond CT-only based practice.

Entities:  

Mesh:

Year:  2013        PMID: 23635279     DOI: 10.1118/1.4800808

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  42 in total

1.  High-quality t2-weighted 4-dimensional magnetic resonance imaging for radiation therapy applications.

Authors:  Dongsu Du; Shelton D Caruthers; Carri Glide-Hurst; Daniel A Low; H Harold Li; Sasa Mutic; Yanle Hu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-03-30       Impact factor: 7.038

Review 2.  Clinical and research applications of simultaneous positron emission tomography and MRI.

Authors:  F Fraioli; S Punwani
Journal:  Br J Radiol       Date:  2013-11-14       Impact factor: 3.039

3.  Accelerating volumetric cine MRI (VC-MRI) using undersampling for real-time 3D target localization/tracking in radiation therapy: a feasibility study.

Authors:  Wendy Harris; Fang-Fang Yin; Chunhao Wang; You Zhang; Jing Cai; Lei Ren
Journal:  Phys Med Biol       Date:  2017-12-14       Impact factor: 3.609

4.  Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy.

Authors:  Tatsuya J Arai; Joris Nofiele; Ananth J Madhuranthakam; Qing Yuan; Ivan Pedrosa; Rajiv Chopra; Amit Sawant
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

5.  Lung dynamic MRI deblurring using low-rank decomposition and dictionary learning.

Authors:  Shuiping Gou; Yueyue Wang; Jiaolong Wu; Percy Lee; Ke Sheng
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

6.  A tool for validating MRI-guided strategies: a digital breathing CT/MRI phantom of the abdominal site.

Authors:  Chiara Paganelli; Paul Summers; Chiara Gianoli; Massimo Bellomi; Guido Baroni; Marco Riboldi
Journal:  Med Biol Eng Comput       Date:  2017-04-08       Impact factor: 2.602

Review 7.  The role of texture analysis in imaging as an outcome predictor and potential tool in radiotherapy treatment planning.

Authors:  S Alobaidli; S McQuaid; C South; V Prakash; P Evans; A Nisbet
Journal:  Br J Radiol       Date:  2014-07-23       Impact factor: 3.039

Review 8.  Motion management in gastrointestinal cancers.

Authors:  Hassan Abbas; Bryan Chang; Zhe Jay Chen
Journal:  J Gastrointest Oncol       Date:  2014-06

9.  Free-breathing liver fat and R 2 quantification using motion-corrected averaging based on a nonlocal means algorithm.

Authors:  Huiwen Luo; Ante Zhu; Curtis N Wiens; Jitka Starekova; Ann Shimakawa; Scott B Reeder; Kevin M Johnson; Diego Hernando
Journal:  Magn Reson Med       Date:  2020-08-01       Impact factor: 4.668

10.  A post-processing method based on interphase motion correction and averaging to improve image quality of 4D magnetic resonance imaging: a clinical feasibility study.

Authors:  Zixin Deng; Jianing Pang; Yi Lao; Xiaoming Bi; Guan Wang; Yuhua Chen; Matthias Fenchel; Richard Tuli; Debiao Li; Wensha Yang; Zhaoyang Fan
Journal:  Br J Radiol       Date:  2019-01-03       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.