Literature DB >> 23623988

A graphene oxide-based FRET sensor for rapid and sensitive detection of matrix metalloproteinase 2 in human serum sample.

Erqun Song1, Dan Cheng, Yang Song, Mingdong Jiang, Jifei Yu, Yunyun Wang.   

Abstract

Graphene oxide (GO) has been widely used to develop fluorescence resonance energy transfer (FRET) biosensors for tumor markers (e.g., matrix metalloproteinases, MMPs) due to its superior fluorescence quenching capacity and unique adsorption characteristics for biomolecules. In this study, fluorescein isothiocyanate-labeled peptide (Pep-FITC) was assembled onto the GO surface through covalent binding to construct a GO-Pep-FITC FRET sensor for sensitive, rapid, and accurate detection of MMP-2 in complex serum samples. Compared to similar GO-based FRET sensors fabricated through physical adsorption, the as prepared ones via covalent binding are significantly more stable under physiological conditions, enabling their detection of MMP-2 with high sensitivity (detection limit: 2.5ng/mL). More importantly, it allows for rapid MMP-2 detection (within 3h) even in complex biological samples with satisfactory accuracy and the relative standard deviation ≤7.03%. Our studies further suggest that such a platform developed here for sensitive, rapid, and accurate detection of biomarkers holds great promise for clinical diagnosis of protease-related diseases.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23623988     DOI: 10.1016/j.bios.2013.03.030

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  11 in total

1.  A Versatile Multiple Target Detection System Based on DNA Nano-assembled Linear FRET Arrays.

Authors:  Yansheng Li; Hongwu Du; Wenqian Wang; Peixun Zhang; Liping Xu; Yongqiang Wen; Xueji Zhang
Journal:  Sci Rep       Date:  2016-05-27       Impact factor: 4.379

Review 2.  Critical overview on the application of sensors and biosensors for clinical analysis.

Authors:  Celine I L Justino; Armando C Duarte; Teresa A P Rocha-Santos
Journal:  Trends Analyt Chem       Date:  2016-04-08       Impact factor: 12.296

3.  Fluorescence Determination of Peptidase Activity Based on the Quenching of a Fluorophore-Labelled Peptide by Graphene Oxide.

Authors:  Dinh-Vu Le
Journal:  Protein J       Date:  2021-04-15       Impact factor: 2.371

4.  Label-Free Fluorescent Detection of Trypsin Activity Based on DNA-Stabilized Silver Nanocluster-Peptide Conjugates.

Authors:  Cai-Xia Zhuo; Li-Hui Wang; Jing-Jing Feng; Yao-Dong Zhang
Journal:  Sensors (Basel)       Date:  2016-11-09       Impact factor: 3.576

Review 5.  Carbon Nanomaterial Based Biosensors for Non-Invasive Detection of Cancer and Disease Biomarkers for Clinical Diagnosis.

Authors:  Tibor Pasinszki; Melinda Krebsz; Thanh Tran Tung; Dusan Losic
Journal:  Sensors (Basel)       Date:  2017-08-20       Impact factor: 3.576

6.  Accelerated 19F·MRI Detection of Matrix Metalloproteinase-2/-9 through Responsive Deactivation of Paramagnetic Relaxation Enhancement.

Authors:  Henryk M Faas; James L Krupa; Alexander J Taylor; Francesco Zamberlan; Christopher J Philp; Huw E L Williams; Simon R Johnson; Galina E Pavlovskaya; Neil R Thomas; Thomas Meersmann
Journal:  Contrast Media Mol Imaging       Date:  2019-02-28       Impact factor: 3.161

Review 7.  Biosensors based on graphene oxide and its biomedical application.

Authors:  Jieon Lee; Jungho Kim; Seongchan Kim; Dal-Hee Min
Journal:  Adv Drug Deliv Rev       Date:  2016-06-11       Impact factor: 15.470

Review 8.  Graphene, an Interesting Nanocarbon Allotrope for Biosensing Applications: Advances, Insights, and Prospects.

Authors:  Farid Menaa; Yazdian Fatemeh; Sandeep K Vashist; Haroon Iqbal; Olga N Sharts; Bouzid Menaa
Journal:  Biomed Eng Comput Biol       Date:  2021-02-24

Review 9.  Bioanalytical methods for circulating extracellular matrix-related proteins: new opportunities in cancer diagnosis.

Authors:  Ramón Lorenzo-Gómez; Rebeca Miranda-Castro; Noemí de-Los-Santos-Álvarez; María Jesús Lobo-Castañón
Journal:  Anal Bioanal Chem       Date:  2021-06-05       Impact factor: 4.142

10.  A reduced graphene oxide-based fluorescence resonance energy transfer sensor for highly sensitive detection of matrix metalloproteinase 2.

Authors:  Gaina Xi; Xiaoping Wang; Tongsheng Chen
Journal:  Int J Nanomedicine       Date:  2016-04-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.