Literature DB >> 23614076

A Randomized Controlled Trial about the Levels of Radiation Exposure Depends on the Use of Collimation C-arm Fluoroscopic-guided Medial Branch Block.

Seung Woo Baek1, Jae Sung Ryu, Cheol Hee Jung, Joo Han Lee, Won Kyoung Kwon, Nam Sik Woo, Hae Kyoung Kim, Jae Hun Kim.   

Abstract

BACKGROUND: C-arm fluoroscope has been widely used to promote more effective pain management; however, unwanted radiation exposure for operators is inevitable. We prospectively investigated the differences in radiation exposure related to collimation in Medial Branch Block (MBB).
METHODS: This study was a randomized controlled trial of 62 MBBs at L3, 4 and 5. After the patient was laid in the prone position on the operating table, MBB was conducted and only AP projections of the fluoroscope were used. Based on a concealed random number table, MBB was performed with (collimation group) and without (control group) collimation. The data on the patient's age, height, gender, laterality (right/left), radiation absorbed dose (RAD), exposure time, distance from the center of the field to the operator, and effective dose (ED) at the side of the table and at the operator's chest were collected. The brightness of the fluoroscopic image was evaluated with histogram in Photoshop.
RESULTS: There were no significant differences in age, height, weight, male to female ratio, laterality, time, distance and brightness of fluoroscopic image. The area of the fluoroscopic image with collimation was 67% of the conventional image. The RAD (29.9 ± 13.0, P = 0.001) and the ED at the left chest of the operators (0.53 ± 0.71, P = 0.042) and beside the table (5.69 ± 4.6, P = 0.025) in collimation group were lower than that of the control group (44.6 ± 19.0, 0.97 ± 0.92, and 9.53 ± 8.16), resepectively.
CONCLUSIONS: Collimation reduced radiation exposure and maintained the image quality. Therefore, the proper use of collimation will be beneficial to both patients and operators.

Entities:  

Keywords:  collimation; image quality; radiation absorbed dose; radiation exposure

Year:  2013        PMID: 23614076      PMCID: PMC3629341          DOI: 10.3344/kjp.2013.26.2.148

Source DB:  PubMed          Journal:  Korean J Pain        ISSN: 2005-9159


  11 in total

1.  Impact of collimation on radiation exposure during interventional electrophysiology.

Authors:  Tomos E Walters; Peter M Kistler; Joseph B Morton; Paul B Sparks; Karen Halloran; Jonathan M Kalman
Journal:  Europace       Date:  2012-04-19       Impact factor: 5.214

2.  Strict X-ray beam collimation for facial bones examination can increase lens exposure.

Authors:  R Powys; J Robinson; P L Kench; J Ryan; P C Brennan
Journal:  Br J Radiol       Date:  2012-02-28       Impact factor: 3.039

Review 3.  Radiation protection of medical staff.

Authors:  John Le Heron; Renato Padovani; Ian Smith; Renate Czarwinski
Journal:  Eur J Radiol       Date:  2010-07-24       Impact factor: 3.528

4.  Occupational radiation protection in interventional radiology: a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology.

Authors:  Donald L Miller; Eliseo Vañó; Gabriel Bartal; Stephen Balter; Robert Dixon; Renato Padovani; Beth Schueler; John F Cardella; Thierry de Baère
Journal:  J Vasc Interv Radiol       Date:  2010-05       Impact factor: 3.464

5.  Governmental regulations and radiation exposure.

Authors:  Lois A Killewich; Terrell A Singleton
Journal:  J Vasc Surg       Date:  2010-09-27       Impact factor: 4.268

6.  The effect of source to image-receptor distance on effective dose for some common X-ray projections.

Authors:  J L Poletti; D McLean
Journal:  Br J Radiol       Date:  2005-09       Impact factor: 3.039

7.  Radiation exposure to the physician performing fluoroscopically guided caudal epidural steroid injections.

Authors:  K P Botwin; E D Freeman; R D Gruber; F M Torres-Rames; C G Bouchtas; J T Sanelli; A F Hanna
Journal:  Pain Physician       Date:  2001-10       Impact factor: 4.965

Review 8.  Radiation safety in fluoroscopy for neuraxial injections.

Authors:  Gerry E Fink
Journal:  AANA J       Date:  2009-08

9.  Radiation safety and education in the applicants of the final test for the expert of pain medicine.

Authors:  Pyong Eun Park; Jung Min Park; Joo Eun Kang; Jae Hun Cho; Suk Ju Cho; Jae Hun Kim; Woo Seog Sim; Yong Chul Kim
Journal:  Korean J Pain       Date:  2012-01-02

10.  A Study to Compare the Radiation Absorbed Dose of the C-arm Fluoroscopic Modes.

Authors:  Jae Hun Cho; Jae Yun Kim; Joo Eun Kang; Pyong Eun Park; Jae Hun Kim; Jeong Ae Lim; Hae Kyoung Kim; Nam Sik Woo
Journal:  Korean J Pain       Date:  2011-11-30
View more
  9 in total

1.  [Intraoperative imaging of children and adolescents, for selected fractures and in follow-up after conservative and operative treatment : Part 2 of the results of a nationwide online survey of the Pediatric Traumatology Section of the German Trauma Society].

Authors:  Klaus Dresing; Francisco Fernandez; Peter Schmittenbecher; Kaya Dresing; Peter Strohm; Christopher Spering; Ralf Kraus
Journal:  Unfallchirurg       Date:  2021-12-16       Impact factor: 1.000

2.  Radiation safety for pain physicians: technique or equipment.

Authors:  Jae Hang Shim
Journal:  Korean J Pain       Date:  2014-03-28

3.  How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?

Authors:  Ah Na Kim; Young Jae Chang; Bo Kyung Cheon; Jae Hun Kim
Journal:  Korean J Pain       Date:  2014-03-28

4.  The Radiation Exposure of Radiographer Related to the Location in C-arm Fluoroscopy-guided Pain Interventions.

Authors:  Young Jae Chang; Ah Na Kim; In Su Oh; Nam Sik Woo; Hae Kyoung Kim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2014-03-28

5.  The radiation safety education and the pain physicians' efforts to reduce radiation exposure.

Authors:  Tae Hee Kim; Seung Wan Hong; Nam Sik Woo; Hae Kyoung Kim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2017-03-31

Review 6.  Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management.

Authors:  Bo Kyung Cheon; Cho Long Kim; Ka Ram Kim; Min Hye Kang; Jeong Ae Lim; Nam Sik Woo; Ka Young Rhee; Hae Kyoung Kim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2018-10-01

Review 7.  Radiation safety for pain physicians: principles and recommendations.

Authors:  Sewon Park; Minjung Kim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2022-04-01

8.  Effect of collimation on radiation exposure and image quality.

Authors:  Mohamed Amin Ghobadifar; Safar Zarei
Journal:  Korean J Pain       Date:  2013-07-01

9.  Evaluation of protective equipment for the reduction of radiation exposure to physicians performing fluoroscopically guided lumbar transforaminal epidural steroid injections: A randomized controlled trial.

Authors:  Won-Joong Kim; Seung Hee Yoo; Hahck Soo Park
Journal:  Medicine (Baltimore)       Date:  2020-07-31       Impact factor: 1.817

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.