Literature DB >> 19731844

Radiation safety in fluoroscopy for neuraxial injections.

Gerry E Fink1.   

Abstract

Certified Registered Nurse Anesthetists (CRNAs) perform epidural steroid injections for chronic back and extremity pain. Placing epidural needles using fluoroscopy and confirming the needle placement by epidurogram has been suggested as a means to increase the efficacy of epidural injections while decreasing complications. Because of the risk of radiation injury to patients and staff when using fluoroscopy, the purpose of this article is to review the concepts of fluoroscopy and radiation safety for CRNAs. Following a literature search using keywords such as fluoroscopy, radiation injury, and radiation safety, relevant articles were identified. In addition, the reference lists of these articles were reviewed to identify other pertinent sources regarding this topic. The risks of stochastic and deterministic effects from radiation exposure necessitate the need for practitioners who are knowledgeable in equipment, patient, and procedure related factors that influence radiation exposure. Practitioner conduct, using the as-low-as-reasonably achievable (ALARA) principle, results in choices regarding these factors that minimize the time and intensity of radiation exposure to patients, anesthesia providers, and staff.

Entities:  

Mesh:

Year:  2009        PMID: 19731844

Source DB:  PubMed          Journal:  AANA J        ISSN: 0094-6354


  6 in total

1.  Comparison of radiation exposure during fluoroscopy-guided transforaminal epidural steroid injections at different vertebral levels.

Authors:  Yun Mi Hwang; Min Hee Lee; Seon-Jeong Kim; Sheen-Woo Lee; Hye Won Chung; Sang Hoon Lee; Myung Jin Shin
Journal:  Korean J Radiol       Date:  2015-02-27       Impact factor: 3.500

2.  Comparison of radiation exposure to physicians between anteroposterior and lateral real-time fluoroscopy when performing lumbar transforaminal epidural steroid injections: A randomized controlled trial.

Authors:  Seung Hee Yoo; Won-Joong Kim; Mi Jin Jue; Min Jin Lee
Journal:  Medicine (Baltimore)       Date:  2022-07-08       Impact factor: 1.817

3.  A Randomized Controlled Trial about the Levels of Radiation Exposure Depends on the Use of Collimation C-arm Fluoroscopic-guided Medial Branch Block.

Authors:  Seung Woo Baek; Jae Sung Ryu; Cheol Hee Jung; Joo Han Lee; Won Kyoung Kwon; Nam Sik Woo; Hae Kyoung Kim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2013-04-03

4.  How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?

Authors:  Ah Na Kim; Young Jae Chang; Bo Kyung Cheon; Jae Hun Kim
Journal:  Korean J Pain       Date:  2014-03-28

5.  The Radiation Exposure of Radiographer Related to the Location in C-arm Fluoroscopy-guided Pain Interventions.

Authors:  Young Jae Chang; Ah Na Kim; In Su Oh; Nam Sik Woo; Hae Kyoung Kim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2014-03-28

Review 6.  Radiation safety for pain physicians: principles and recommendations.

Authors:  Sewon Park; Minjung Kim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2022-04-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.