Transcatheter aortic valve implantation in patients of small body size.

Yusuke Watanabe1, Kentaro Hayashida, Thierry Lefèvre, Bernard Chevalier, Thomas Hovasse, Mauro Romano, Philippe Garot, Arnaud Farge, Patrick Donzeau-Gouge, Erik Bouvier, Bertrand Cormier, Marie-Claude Morice.   

Abstract

AIMS: The aim of this study was to evaluate the efficacy and safety of transcatheter aortic valve implantation (TAVI) in patients of small body size (SB). METHODS AND
RESULTS: Between October 2006 and November 2011, 424 patients undergoing TAVI were evaluated. Patients with a small body surface area (BSA; <1.75 m(2)) were defined as the "SB group" (n = 215) and the remaining large BSA patients as the "LB group" (n = 209). In the SB group, mean annulus diameter measured by CT and minimal femoral artery diameter were significantly smaller (23.1 ± 1.92 vs. 24.3 ± 1.91 mm, P < 0.01; 7.59 ± 1.06 vs. 8.29 ± 1.34 mm, P < 0.01, respectively). The logistic EuroSCORE was similar between groups (22.5 ± 10.4 vs. 23.4 ± 12.0; P = 0.43). Equivalent device success (91.2% vs. 91.4%; P = 0.94) and 30-day survival rates (85.1% vs. 87.6%; P = 0.46) were achieved in both groups. Vascular complications and the 30-day combined safety end point rate were significantly higher in the SB group (13.0% vs. 4.3%, P < 0.01; 27.4% vs. 18.3%, P = 0.03, respectively). Similar post-procedural mean pressure gradient was achieved in both groups (10.2 ± 4.3 vs. 11.0 ± 4.6 mmHg; P = 0.12). Multivariate analysis showed that BSA was one of the independent predictors of 30-day combined safety end point (Odds ratio: 0.20; 95% confidence interval (CI): 0.05-0.88; P = 0.03). However, Kaplan-Meier analysis revealed no significant difference in mid-term survival rate between groups (log-rank P = 0.64).
CONCLUSIONS: TAVI in SB patients resulted in similar clinical outcomes with effective post-procedural hemodynamics compared with LB patients. Care should be taken to avoid vascular complications in SB patients.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  aortic valve; small body size; transcatheter aortic valve implantation; vascular complication

Mesh:

Year:  2014        PMID: 23613222     DOI: 10.1002/ccd.24970

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  6 in total

1.  Prognostic value of body mass index and body surface area on clinical outcomes after transcatheter aortic valve implantation.

Authors:  Mani Arsalan; Giovanni Filardo; Won-Keun Kim; John J Squiers; Benjamin Pollock; Christoph Liebetrau; Johannes Blumenstein; Jörg Kempfert; Arnaud Van Linden; Annika Arsalan-Werner; Christian Hamm; Michael J Mack; Helge Moellmann; Thomas Walther
Journal:  Clin Res Cardiol       Date:  2016-08-17       Impact factor: 5.460

Review 2.  Transcatheter Aortic Valve Implantation in Small Anatomy: Patient Selection and Technical Challenges.

Authors:  Makoto Nakashima; Yusuke Watanabe
Journal:  Interv Cardiol       Date:  2018-05

3.  Low Incidence of Prosthesis-Patient Mismatch Following Extremely Small Transcatheter Aortic Valve Replacement with 20-mm Sapien 3.

Authors:  Kazue Okajima; Ikki Komatsu; Todd B Seto
Journal:  Int J Angiol       Date:  2021-08-25

Review 4.  Annular Rupture During Transcatheter Aortic Valve Implantation: Predictors, Management and Outcomes.

Authors:  J J Coughlan; Thomas Kiernan; Darren Mylotte; Samer Arnous
Journal:  Interv Cardiol       Date:  2018-09

5.  Transcatheter Aortic Valve Implantation for Patients with Smaller Anatomy.

Authors:  Yusuke Watanabe; Ken Kozuma
Journal:  Interv Cardiol       Date:  2015-09

6.  Editorial: Transcatheter aortic valve implantation as a daily clinical practice in Japan.

Authors:  Yusuke Watanabe
Journal:  J Cardiol Cases       Date:  2015-08-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.