Literature DB >> 35833173

Low Incidence of Prosthesis-Patient Mismatch Following Extremely Small Transcatheter Aortic Valve Replacement with 20-mm Sapien 3.

Kazue Okajima1,2, Ikki Komatsu3,4, Todd B Seto1,3.   

Abstract

Transcatheter aortic valve replacement has been developed as an emerging technique to treat patients with aortic valve disease. However, safety and outcome data on extremely small transcatheter heart valves (THV) is limited. We aimed to assess hemodynamic profiles and clinical outcome of very small balloon expandable THVs with 20-mm Sapien 3 (SP3). We examined data for all patients who received third-generation SP3 THV at a single hospital. Complications and clinical outcomes were defined based on the VARC-2 criteria. Postoperative prosthesis-patient mismatch (PPM) was defined as indexed effective orifice area (EOA) < 0.85 cm 2 /m 2 . We compared clinical characteristics and outcome between patients with 20-mm ( n  = 21), 23-mm ( n  = 67), and 26- or 29-mm ( n  = 113) sized valves. The 20-mm group included significantly higher number of Asian and female populations with lower body surface area. The baseline CT annular area in the 20-mm group was 316.5 ± 24.9 mm 2 . There was no significant difference between groups in procedural mortality or early safety at 30 days. The higher procedural complication was observed in 20-mm group due to significant differences in minor vascular and bleeding complications. Despite higher post-THV gradients and smaller indexed EOA in 20-mm group, no PPM was observed in 20-mm group. The mortality at 30 days and 1 year in 20-mm group was 4.8% and 16.7%, respectively. The patients who received very small THVs with 20-mm SP3 did not result in PPM and experienced favorable early safety and midterm outcome in our cohort. International College of Angiology. This article is published by Thieme.

Entities:  

Keywords:  aortic stenosis; outcome; prosthesis-patient mismatch; small aortic annulus; transcatheter aortic valve replacement

Year:  2021        PMID: 35833173      PMCID: PMC9272262          DOI: 10.1055/s-0041-1732316

Source DB:  PubMed          Journal:  Int J Angiol        ISSN: 1061-1711


  21 in total

1.  Impact of Annular Size on Outcomes After Surgical or Transcatheter Aortic Valve Replacement.

Authors:  G Michael Deeb; Stanley J Chetcuti; Steven J Yakubov; Himanshu J Patel; P Michael Grossman; Neal S Kleiman; John Heiser; William Merhi; George L Zorn; Peter N Tadros; George Petrossian; Newell Robinson; Mubashir Mumtaz; Thomas G Gleason; Jian Huang; John V Conte; Jeffrey J Popma; Michael J Reardon
Journal:  Ann Thorac Surg       Date:  2018-01-05       Impact factor: 4.330

2.  Comprehensive Echocardiographic Assessment of Normal Transcatheter Valve Function.

Authors:  Rebecca T Hahn; Jonathon Leipsic; Pamela S Douglas; Wael A Jaber; Neil J Weissman; Philippe Pibarot; Philipp Blanke; Jae K Oh
Journal:  JACC Cardiovasc Imaging       Date:  2018-06-13

3.  Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients.

Authors:  Jeffrey J Popma; G Michael Deeb; Steven J Yakubov; Mubashir Mumtaz; Hemal Gada; Daniel O'Hair; Tanvir Bajwa; John C Heiser; William Merhi; Neal S Kleiman; Judah Askew; Paul Sorajja; Joshua Rovin; Stanley J Chetcuti; David H Adams; Paul S Teirstein; George L Zorn; John K Forrest; Didier Tchétché; Jon Resar; Antony Walton; Nicolo Piazza; Basel Ramlawi; Newell Robinson; George Petrossian; Thomas G Gleason; Jae K Oh; Michael J Boulware; Hongyan Qiao; Andrew S Mugglin; Michael J Reardon
Journal:  N Engl J Med       Date:  2019-03-16       Impact factor: 91.245

4.  Impact of prosthesis-iteration evolution and sizing practice on the incidence of prosthesis-patient mismatch after transcatheter aortic valve replacement.

Authors:  Mohammad Abdelghani; Abdelhakim Allali; Jatinderjit Kaur; Rayyan Hemetsberger; Julinda Mehilli; Franz-Josef Neumann; Christian Frerker; Thomas Kurz; Mohamed El-Mawardy; Gert Richardt; Mohamed Abdel-Wahab
Journal:  Catheter Cardiovasc Interv       Date:  2018-11-23       Impact factor: 2.692

5.  Clinical Outcomes Following Transcatheter Aortic Valve Replacement in Asian Population.

Authors:  Sung-Han Yoon; Jung-Min Ahn; Kentaro Hayashida; Yusuke Watanabe; Shinichi Shirai; Hsien-Li Kao; Wei-Hsian Yin; Michael Kang-Yin Lee; Edgar Tay; Motoharu Araki; Futoshi Yamanaka; Takahide Arai; Mao-Shin Lin; Jun-Bean Park; Duk-Woo Park; Soo-Jin Kang; Seung-Whan Lee; Young-Hak Kim; Cheol Whan Lee; Seong-Wook Park; Toshiya Muramatsu; Michiya Hanyu; Ken Kozuma; Hyo-Soo Kim; Shigeru Saito; Seung-Jung Park
Journal:  JACC Cardiovasc Interv       Date:  2016-05-09       Impact factor: 11.195

6.  Long-Term Mortality and Early Valve Dysfunction According to Anticoagulation Use: The FRANCE TAVI Registry.

Authors:  Pavel Overtchouk; Paul Guedeney; Stéphanie Rouanet; Jean Philippe Verhoye; Thierry Lefevre; Eric Van Belle; Helene Eltchaninoff; Martine Gilard; Pascal Leprince; Bernard Iung; Olivier Barthelemy; Hervé Le Breton; Géraud Souteyrand; Eric Vicaut; Gilles Montalescot; Jean-Philippe Collet
Journal:  J Am Coll Cardiol       Date:  2018-08-25       Impact factor: 24.094

Review 7.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document.

Authors:  A Pieter Kappetein; Stuart J Head; Philippe Généreux; Nicolo Piazza; Nicolas M van Mieghem; Eugene H Blackstone; Thomas G Brott; David J Cohen; Donald E Cutlip; Gerrit-Anne van Es; Rebecca T Hahn; Ajay J Kirtane; Mitchell W Krucoff; Susheel Kodali; Michael J Mack; Roxana Mehran; Josep Rodés-Cabau; Pascal Vranckx; John G Webb; Stephan Windecker; Patrick W Serruys; Martin B Leon
Journal:  J Am Coll Cardiol       Date:  2012-10-09       Impact factor: 24.094

8.  Transcatheter aortic valve replacement with Evolut R versus Sapien 3 in Japanese patients with a small aortic annulus: The OCEAN-TAVI registry.

Authors:  Hiromu Hase; Nobuhiro Yoshijima; Ryo Yanagisawa; Makoto Tanaka; Hikaru Tsuruta; Hideyuki Shimizu; Keiichi Fukuda; Toru Naganuma; Kazuki Mizutani; Masahiro Yamawaki; Norio Tada; Futoshi Yamanaka; Shinichi Shirai; Minoru Tabata; Hiroshi Ueno; Kensuke Takagi; Yusuke Watanabe; Masanori Yamamoto; Kentaro Hayashida
Journal:  Catheter Cardiovasc Interv       Date:  2020-09-14       Impact factor: 2.692

9.  No clinical effect of prosthesis-patient mismatch after transcatheter versus surgical aortic valve replacement in intermediate- and low-risk patients with severe aortic valve stenosis at mid-term follow-up: an analysis from the NOTION trial.

Authors:  Hans Gustav Hørsted Thyregod; Daniel Andreas Steinbrüchel; Nikolaj Ihlemann; Thuc Anh Ngo; Henrik Nissen; Bo Juel Kjeldsen; Yanping Chang; Peter Bo Hansen; Peter Skov Olsen; Lars Søndergaard
Journal:  Eur J Cardiothorac Surg       Date:  2016-03-22       Impact factor: 4.191

10.  Incidence and predictors of prosthesis-patient mismatch after TAVI using SAPIEN 3 in Asian: differences between the newer and older balloon-expandable valve.

Authors:  Masaki Miyasaka; Norio Tada; Masataka Taguri; Shigeaki Kato; Yusuke Enta; Masaki Hata; Yusuke Watanabe; Toru Naganuma; Masahiro Yamawaki; Futoshi Yamanaka; Shinichi Shirai; Hiroshi Ueno; Kazuki Mizutani; Minoru Tabata; Kensuke Takagi; Masanori Yamamoto; Kentaro Hayashida
Journal:  Open Heart       Date:  2021-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.