Fabrication and in vivo thrombogenicity testing of nitric oxide generating artificial lungs.

Kagya A Amoako1, Patrick J Montoya, Terry C Major, Ahmed B Suhaib, Hitesh Handa, David O Brant, Mark E Meyerhoff, Robert H Bartlett, Keith E Cook.   

Abstract

Hollow fiber artificial lungs are increasingly being used for long-term applications. However, clot formation limits their use to 1-2 weeks. This study investigated the effect of nitric oxide generating (NOgen) hollow fibers on artificial lung thrombogenicity. Silicone hollow fibers were fabricated to incorporate 50 nm copper particles as a catalyst for NO generation from the blood. Fibers with and without (control) these particles were incorporated into artificial lungs with a 0.1 m(2) surface area and inserted in circuits coated tip-to-tip with the NOgen material. Circuits (N = 5/each) were attached to rabbits in a pumpless, arterio-venous configuration and run for 4 h at an activated clotting time of 350-400 s. Three control circuits clotted completely, while none of the NOgen circuits failed. Accordingly, blood flows were significantly higher in the NOgen group (95.9 ± 11.7, p < 0.01) compared to the controls (35.2 ± 19.7; mL/min), and resistance was significantly higher in the control group after 4 h (15.38 ± 9.65, p < 0.001) than in NOgen (0.09 ± 0.03; mmHg/mL/min). On the other hand, platelet counts and plasma fibrinogen concentration expressed as percent of baseline in control group (63.7 ± 5.7%, 77.2 ± 5.6%; p < 0.05) were greater than those in the NOgen group (60.4 ± 5.1%, 63.2 ± 3.7%). Plasma copper levels in the NOgen group were 2.8 times baseline at 4 h (132.8 ± 4.5 μg/dL) and unchanged in the controls. This study demonstrates that NO generating gas exchange fibers could be a potentially effective way to control coagulation inside artificial lungs.
Copyright © 2013 Wiley Periodicals, Inc., a Wiley Company.

Entities:  

Keywords:  artificial lung; biocompatibility; extracorporeal circulation; nitric oxide; silicone; thrombosis

Mesh:

Substances:

Year:  2013        PMID: 23613156      PMCID: PMC3812367          DOI: 10.1002/jbm.a.34655

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  26 in total

1.  Current techniques to improve the blood compatibility of biomaterial surfaces.

Authors:  G H Engbers; J Feijen
Journal:  Int J Artif Organs       Date:  1991-04       Impact factor: 1.595

Review 2.  Platelets in inflammation and atherogenesis.

Authors:  Meinrad Gawaz; Harald Langer; Andreas E May
Journal:  J Clin Invest       Date:  2005-12       Impact factor: 14.808

3.  Nitric oxide-generating silicone as a blood-contacting biomaterial.

Authors:  Kagya A Amoako; Keith E Cook
Journal:  ASAIO J       Date:  2011 Nov-Dec       Impact factor: 2.872

Review 4.  Design of nonthrombogenic polymer surfaces for blood-contacting medical devices.

Authors:  S W Kim; H Jacobs
Journal:  Blood Purif       Date:  1996       Impact factor: 2.614

5.  Percutaneous extracorporeal arteriovenous CO2 removal for severe respiratory failure.

Authors:  J B Zwischenberger; S A Conrad; S K Alpard; L R Grier; A Bidani
Journal:  Ann Thorac Surg       Date:  1999-07       Impact factor: 4.330

6.  Comparison of Sarns 3M heparin bonded to Duraflo II and control circuits in a porcine model: macro- and microanalysis of thrombi accumulation in circuit arterial filters.

Authors:  D F Larson; D Arzouman; L Kleinert; V Patula; S Williams
Journal:  Perfusion       Date:  2000-01       Impact factor: 1.972

7.  Neutrophils phagocytose activated platelets in vivo: a phosphatidylserine, P-selectin, and {beta}2 integrin-dependent cell clearance program.

Authors:  Norma Maugeri; Patrizia Rovere-Querini; Virgilio Evangelista; Cesare Covino; Annalisa Capobianco; Maria T S Bertilaccio; Antonio Piccoli; Licia Totani; Domenico Cianflone; Attilio Maseri; Angelo A Manfredi
Journal:  Blood       Date:  2009-03-04       Impact factor: 22.113

Review 8.  The molecular basis of platelet and endothelial cell interaction with neutrophils and monocytes: role of P-selectin and the P-selectin ligand, PSGL-1.

Authors:  B Furie; B C Furie
Journal:  Thromb Haemost       Date:  1995-07       Impact factor: 5.249

9.  Nitric oxide-generating compounds inhibit total protein and collagen synthesis in cultured vascular smooth muscle cells.

Authors:  V Kolpakov; D Gordon; T J Kulik
Journal:  Circ Res       Date:  1995-02       Impact factor: 17.367

10.  Catalytic generation of nitric oxide from nitrite at the interface of polymeric films doped with lipophilic CuII-complex: a potential route to the preparation of thromboresistant coatings.

Authors:  Bong Kyun Oh; Mark E Meyerhoff
Journal:  Biomaterials       Date:  2004-01       Impact factor: 12.479

View more
  7 in total

1.  Fourteen Day In Vivo Testing of a Compliant Thoracic Artificial Lung.

Authors:  David J Skoog; Joshua R Pohlmann; David S Demos; Christopher N Scipione; Amit Iyengar; Rebecca E Schewe; Ahmed B Suhaib; Kelly L Koch; Keith E Cook
Journal:  ASAIO J       Date:  2017 Sep/Oct       Impact factor: 2.872

Review 2.  In Vitro models for thrombogenicity testing of blood-recirculating medical devices.

Authors:  Deepika N Sarode; Shuvo Roy
Journal:  Expert Rev Med Devices       Date:  2019-06-10       Impact factor: 3.166

3.  72-Hour in vivo evaluation of nitric oxide generating artificial lung gas exchange fibers in sheep.

Authors:  Angela Lai; Caitlin T Demarest; Chi Chi Do-Nguyen; Rei Ukita; David J Skoog; Neil M Carleton; Kagya A Amoako; Patrick J Montoya; Keith E Cook
Journal:  Acta Biomater       Date:  2019-04-03       Impact factor: 8.947

Review 4.  Development and hemocompatibility testing of nitric oxide releasing polymers using a rabbit model of thrombogenicity.

Authors:  Terry C Major; Hitesh Handa; Gail M Annich; Robert H Bartlett
Journal:  J Biomater Appl       Date:  2014-06-16       Impact factor: 2.646

5.  Microfluidic cell sorting: Towards improved biocompatibility of extracorporeal lung assist devices.

Authors:  Christian Bleilevens; Jonas Lölsberg; Arne Cinar; Maren Knoben; Oliver Grottke; Rolf Rossaint; Matthias Wessling
Journal:  Sci Rep       Date:  2018-05-23       Impact factor: 4.379

Review 6.  Advances in extracorporeal membrane oxygenator design for artificial placenta technology.

Authors:  David G Blauvelt; Emily N Abada; Peter Oishi; Shuvo Roy
Journal:  Artif Organs       Date:  2020-11-04       Impact factor: 3.094

Review 7.  Bioengineering Progress in Lung Assist Devices.

Authors:  Ahad Syed; Sarah Kerdi; Adnan Qamar
Journal:  Bioengineering (Basel)       Date:  2021-06-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.