72-Hour in vivo evaluation of nitric oxide generating artificial lung gas exchange fibers in sheep.

Angela Lai1, Caitlin T Demarest2, Chi Chi Do-Nguyen2, Rei Ukita2, David J Skoog2, Neil M Carleton2, Kagya A Amoako3, Patrick J Montoya4, Keith E Cook2.   

Abstract

The large, densely packed artificial surface area of artificial lungs results in rapid clotting and device failure. Surface generated nitric oxide (NO) can be used to reduce platelet activation and coagulation on gas exchange fibers, while not inducing patient bleeding due to its short half-life in blood. To generate NO, artificial lungs can be manufactured with PDMS hollow fibers embedded with copper nanoparticles (Cu NP) and supplied with an infusion of the NO donor S-nitroso-N-acetyl-penicillamine (SNAP). The SNAP reacts with Cu NP to generate NO. This study investigates clot formation and gas exchange performance of artificial lungs with either NO-generating Cu-PDMS or standard polymethylpentene (PMP) fibers. One miniature artificial lung (MAL) made with 10 wt% Cu-PDMS hollow fibers and one PMP control MAL were attached to sheep in parallel in a veno-venous extracorporeal membrane oxygenation circuit (n = 8). Blood flow through each device was set at 300 mL/min, and each device received a SNAP infusion of 0.12 μmol/min. The ACT was between 110 and 180 s in all cases. Blood flow resistance was calculated as a measure of clot formation on the fiber bundle. Gas exchange experiments comparing the two groups were conducted every 24 h at blood flow rates of 300 and 600 mL/min. Devices were removed once the resistance reached 3x baseline (failure) or following 72 h. All devices were imaged using scanning electron microscopy (SEM) at the inlet, outlet, and middle of the fiber bundle. The Cu-PDMS NO generating MALs had a significantly smaller increase in resistance compared to the control devices. Resistance rose from 26 ± 8 and 23 ± 5 in the control and Cu-PDMS devices, respectively, to 35 ± 8 mmHg/(mL/min) and 72 ± 23 mmHg/(mL/min) at the end of each experiment. The resistance and SEM imaging of fiber surfaces demonstrate lower clot formation on Cu-PDMS fibers. Although not statistically significant, oxygen transfer for the Cu-PDMS MALs was 13.3% less than the control at 600 mL/min blood flow rate. Future in vivo studies with larger Cu-PDMS devices are needed to define gas exchange capabilities and anticoagulant activity over a long-term study at clinically relevant ACTs. STATEMENT OF SIGNIFICANCE: In artificial lungs, the large, densely-packed blood contacting surface area of the hollow fiber bundle is critical for gas exchange but also creates rapid, surface-generated clot requiring significant anticoagulation. Monitoring of anticoagulation, thrombosis, and resultant complications has kept permanent respiratory support from becoming a clinical reality. In this study, we use a hollow fiber material that generates nitric oxide (NO) to prevent platelet activation at the blood contacting surface. This material is tested in vivo in a miniature artificial lung and compared against the clinical standard. Results indicated significantly reduced clot formation. Surface-focused anticoagulation like this should reduce complication rates and allow for permanent respiratory support by extending the functional lifespan of artificial lungs and can further be applied to other medical devices.
Copyright © 2019 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Anti-platelet; Artificial lung; Coagulation; Nitric oxide; Oxygenator

Mesh:

Substances:

Year:  2019        PMID: 30953800      PMCID: PMC6513705          DOI: 10.1016/j.actbio.2019.04.004

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  41 in total

1.  Short communication serum copper, zinc, and calcium concentrations in lice-infested sheep.

Authors:  Y Deger; S Dede; S Deger
Journal:  Biol Trace Elem Res       Date:  2002-07       Impact factor: 3.738

2.  The catastrophe revisited: blood compatibility in the 21st Century.

Authors:  Buddy D Ratner
Journal:  Biomaterials       Date:  2007-08-08       Impact factor: 12.479

Review 3.  Manifestations of copper excess.

Authors:  I Bremner
Journal:  Am J Clin Nutr       Date:  1998-05       Impact factor: 7.045

4.  Mechanical ventilation management during extracorporeal membrane oxygenation for acute respiratory distress syndrome: a retrospective international multicenter study.

Authors:  Matthieu Schmidt; Claire Stewart; Michael Bailey; Ania Nieszkowska; Joshua Kelly; Lorna Murphy; David Pilcher; D James Cooper; Carlos Scheinkestel; Vincent Pellegrino; Paul Forrest; Alain Combes; Carol Hodgson
Journal:  Crit Care Med       Date:  2015-03       Impact factor: 7.598

5.  Nitric oxide-generating silicone as a blood-contacting biomaterial.

Authors:  Kagya A Amoako; Keith E Cook
Journal:  ASAIO J       Date:  2011 Nov-Dec       Impact factor: 2.872

6.  The hemocompatibility of a nitric oxide generating polymer that catalyzes S-nitrosothiol decomposition in an extracorporeal circulation model.

Authors:  Terry C Major; David O Brant; Charles P Burney; Kagya A Amoako; Gail M Annich; Mark E Meyerhoff; Hitesh Handa; Robert H Bartlett
Journal:  Biomaterials       Date:  2011-06-22       Impact factor: 12.479

7.  Improved hemocompatibility of silicone rubber extracorporeal tubing via solvent swelling-impregnation of S-nitroso-N-acetylpenicillamine (SNAP) and evaluation in rabbit thrombogenicity model.

Authors:  Elizabeth J Brisbois; Terry C Major; Marcus J Goudie; Robert H Bartlett; Mark E Meyerhoff; Hitesh Handa
Journal:  Acta Biomater       Date:  2016-04-16       Impact factor: 8.947

8.  Bridge to lung transplantation with the novel pumpless interventional lung assist device NovaLung.

Authors:  Stefan Fischer; Andre R Simon; Tobias Welte; Marius M Hoeper; Anna Meyer; Rene Tessmann; Bernhard Gohrbandt; Jens Gottlieb; Axel Haverich; Martin Strueber
Journal:  J Thorac Cardiovasc Surg       Date:  2006-03       Impact factor: 5.209

9.  Association of bleeding and thrombosis with outcome in extracorporeal life support.

Authors:  Heidi J Dalton; Pamela Garcia-Filion; Richard Holubkov; Frank W Moler; Thomas Shanley; Sabrina Heidemann; Kathleen Meert; Robert A Berg; John Berger; Joseph Carcillo; Christopher Newth; Richard Harrison; Allan Doctor; Peter Rycus; J Michael Dean; Tammara Jenkins; Carol Nicholson
Journal:  Pediatr Crit Care Med       Date:  2015-02       Impact factor: 3.624

10.  Serum copper and haematological values of sheep of different physiological stages in the dry and wet seasons of central trinidad.

Authors:  A Mohammed; M Campbell; F G Youssef
Journal:  Vet Med Int       Date:  2014-05-08
View more
  2 in total

Review 1.  Advances in extracorporeal membrane oxygenator design for artificial placenta technology.

Authors:  David G Blauvelt; Emily N Abada; Peter Oishi; Shuvo Roy
Journal:  Artif Organs       Date:  2020-11-04       Impact factor: 3.094

Review 2.  Bioengineering Progress in Lung Assist Devices.

Authors:  Ahad Syed; Sarah Kerdi; Adnan Qamar
Journal:  Bioengineering (Basel)       Date:  2021-06-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.