An analysis of radiation dose reduction in paediatric interventional cardiology by altering frame rate and use of the anti-scatter grid.

S L McFadden1, C M Hughes, R B Mooney, Robert J Winder.   

Abstract

The purpose of this work is to investigate removal of the anti-scatter grid and alteration of the frame rate in paediatric interventional cardiology (IC) and assess the impact on radiation dose and image quality. Phantom based experimental studies were performed in a dedicated cardiac catheterisation suite to investigate variations in radiation dose and image quality, with various changes in imaging parameters. Phantom based experimental studies employing these variations in technique identified that radiation dose reductions of 28%-49% can be made to the patient with minimal loss of image quality in smaller sized patients. At present, there is no standard technique for carrying out paediatric IC in the UK or Ireland, resulting in the potential for a wide variation in radiation dose. Dose reductions to patients can be achieved with slight alterations to the imaging equipment with minimal compromise to the image quality. These simple modifications can be easily implemented in clinical practice in IC centres.

Entities:  

Mesh:

Year:  2013        PMID: 23612568     DOI: 10.1088/0952-4746/33/2/433

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  5 in total

1.  White Paper on P4 Concepts for Pediatric Imaging.

Authors:  Heike E Daldrup-Link; Christina Sammet; Marta Hernanz-Schulman; Katherine A Barsness; Anne Marie Cahill; Ellen Chung; Andrea S Doria; Kassa Darge; Rajesh Krishnamurthy; Matthew P Lungren; Sheila Moore; Laura Olivieri; Ashok Panigrahy; Alexander J Towbin; Andrew Trout; Stephan Voss
Journal:  J Am Coll Radiol       Date:  2016-02-02       Impact factor: 5.532

2.  Removal of Antiscatter Grids for Spinal Digital Subtraction Angiography: Dose Reduction without Loss of Diagnostic Value.

Authors:  Emanuele Orrù; Amgad El Mekabaty; Diego San Millan; Monica S Pearl; Philippe Gailloud
Journal:  Radiology       Date:  2020-03-03       Impact factor: 11.105

Review 3.  Radiation Exposure in Pediatric Interventional Procedures.

Authors:  Agapi Ploussi; Elias Brountzos; Spyridon Rammos; Sotiria Apostolopoulou; Efstathios P Efstathopoulos
Journal:  Cardiovasc Intervent Radiol       Date:  2021-05-19       Impact factor: 2.740

4.  Radiation Dose Optimization in Interventional Cardiology: A Teaching Hospital Experience.

Authors:  M K Badawy; T Clark; D Carrion; P Deb; O Farouque
Journal:  Cardiol Res Pract       Date:  2018-04-15       Impact factor: 1.866

5.  Comparison of pediatric radiation dose and vessel visibility on angiographic systems using piglets as a surrogate: antiscatter grid removal vs. lower detector air kerma settings with a grid - a preclinical investigation.

Authors:  Keith J Strauss; John M Racadio; Todd A Abruzzo; Neil D Johnson; Manish N Patel; Kamlesh U Kukreja; Mark J H den Hartog; Bart P A Hoonaert; Rami A Nachabe
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.