OBJECTIVE: To assess the effect of wear-time recording on subjective and objective wear time.
MATERIALS AND METHODS: This study retrospectively examined a group of 18 patients and a control group of 14 patients at four appointments over 168 days. The patients were treated with removable appliances with embedded TheraMon-microsensors to be worn for 15 hours per day. The study group was not told about the microsensor until the first appointment after fitting of the appliance. At each appointment patients were asked about their subjective wear time and afterward were told about the objective wear time. The existence of the microsensor was revealed to the control group when the appliance was fitted. Objective wear time was also announced at every appointment.
RESULTS: Mean wear times did not significantly differ between groups at any appointment or regarding overall wear time. Highly significant differences between subjective and objective wear time were found when patients did not know that their wear time had been monitored.
CONCLUSION: Mean wear times assessed in this study concur with data of previous studies. Patients tend to overestimate their wear times but become more realistic once they know wear time is being monitored. Objective measurement of wear time allows a more realistic view of compliance by patient and orthodontist. Knowing that wear time is recorded does not necessarily increase the amount of time removable appliances are worn by the patient.

Entities:  

Mesh:

Year:  2013        PMID: 23611166      PMCID: PMC8722835          DOI: 10.2319/010913-25.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  22 in total

1.  A microsensor for monitoring removable-appliance wear.

Authors:  Timm Cornelius Schott; Björn Ludwig; Bettina A Glasl; Jörg A Lisson
Journal:  J Clin Orthod       Date:  2011-09

Review 2.  [Retention and relapse. Review of the literature].

Authors:  Miklós Kaan; Melinda Madléna
Journal:  Fogorv Sz       Date:  2011-12

3.  [The realization of a wear-timing device for clarifying the scientific questions presented in orthodontics].

Authors:  G Sahm
Journal:  Fortschr Kieferorthop       Date:  1990-08

Review 4.  [The wear-timing measuring device in orthodontics--cui bono? Reflections on the state-of-the-art in wear-timing measurement and compliance research in orthodontics].

Authors:  E Witt; A Bartsch; G Sahm
Journal:  Fortschr Kieferorthop       Date:  1991-06

5.  Hawley retainers full- or part-time? A randomized clinical trial.

Authors:  M Shawesh; B Bhatti; T Usmani; N Mandall
Journal:  Eur J Orthod       Date:  2009-10-01       Impact factor: 3.075

6.  Micro-electronic monitoring of functional appliance wear.

Authors:  G Sahm; A Bartsch; E Witt
Journal:  Eur J Orthod       Date:  1990-08       Impact factor: 3.075

7.  Posttreatment compliance with removable maxillary retention in a teenage population: a short-term randomized clinical trial.

Authors:  Marc Bernard Ackerman; Barry Thornton
Journal:  Orthodontics (Chic.)       Date:  2011

8.  Comparing subjective and objective measures of headgear compliance.

Authors:  Annemieke Bos; Cornelis J Kleverlaan; Johan Hoogstraten; Birte Prahl-Andersen; Rein Kuitert
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-12       Impact factor: 2.650

9.  [The determinants of wear behavior in treatment with removable orthodontic appliances].

Authors:  E Witt; A Bartsch; G Sahm; S Schneider
Journal:  Fortschr Kieferorthop       Date:  1992-12

10.  Psychological timing of orthodontic treatment.

Authors:  J Weiss; H M Eiser
Journal:  Am J Orthod       Date:  1977-08
View more
  7 in total

1.  Adherence to instructions and fluctuation of force magnitude in cervical headgear therapy.

Authors:  Tuula Talvitie; Mika Helminen; Susanna Karsila; Reeta Varho; Luca Signorelli; Timo Peltomäki
Journal:  Angle Orthod       Date:  2018-11-19       Impact factor: 2.079

2.  Stability of orthodontic treatment outcomes after 1-year treatment with the eruption guidance appliance in the early mixed dentition: A follow-up study.

Authors:  Rita Myrlund; Katri Keski-Nisula; Heidi Kerosuo
Journal:  Angle Orthod       Date:  2018-11-20       Impact factor: 2.079

3.  Assessment of Factors Affecting Adolescent Patients' Compliance with Hawley and Vacuum Formed Retainers.

Authors:  Behnam Mirzakouchaki; Sajjad Shirazi; Reza Sharghi; Samaneh Shirazi
Journal:  J Clin Diagn Res       Date:  2016-06-01

4.  How patient-selected colors for removable appliances are reflected in electronically tracked compliance (wear times and wear behavior).

Authors:  Timm C Schott; Dieter Menne
Journal:  Angle Orthod       Date:  2018-03-27       Impact factor: 2.079

5.  The Use of Microsensors to Assess the Daily Wear Time of Removable Orthodontic Appliances: A Prospective Cohort Study.

Authors:  Marek Nahajowski; Joanna Lis; Michał Sarul
Journal:  Sensors (Basel)       Date:  2022-03-22       Impact factor: 3.576

6.  Effect of electronic reminders on patients' compliance during clear aligner treatment: an interrupted time series study.

Authors:  Lan Huong Timm; Gasser Farrag; Daniel Wolf; Martin Baxmann; Falk Schwendicke
Journal:  Sci Rep       Date:  2022-10-05       Impact factor: 4.996

7.  Quantification of wear-time adherence of removable appliances in young orthodontic patients in relation to their BMI: a preliminary study.

Authors:  Timm Cornelius Schott; Björn Ludwig
Journal:  Patient Prefer Adherence       Date:  2014-11-17       Impact factor: 2.711

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.