Literature DB >> 23604757

Grading system for the selection of patients with congenital aural atresia for active middle ear implants.

Henning Frenzel1, Georg Sprinzl, Gerlig Widmann, Dirk Petersen, Barbara Wollenberg, Christian Mohr.   

Abstract

INTRODUCTION: Active middle ear implants (aMEI) are being increasingly used for hearing restoration in congenital aural atresia. The existing gradings used for CT findings do not meet the requirements for these implants. Some items are expendable, whereas other important imaging factors are missing. We aimed to create a new grading system that could describe the extent of the malformation and predict the viability and challenges of implanting an aMEI.
METHODS: One hundred three malformed ears were evaluated using HRCT of the temporal bone. The qualitative items middle ear and mastoid pneumatization, oval window, stapes, round window, tegmen mastoideum displacement and facial nerve displacement were included. An anterior- and posterior round window corridor, oval window and stapes corridor were quantified and novelly included. They describe the size of the surgical field and the sight towards the windows.
RESULTS: The ears were graded on a 16-point scale (16-13 easy, 12-9 moderate, 8-5 difficult, 4-0 high risk). The strength of agreement between the calculated score and the performed implantations was good. The comparison of the new 16-point scale with the Jahrsdoerfer score showed that both were able to conclusively detect the high-risk group; however, the new 16-point scale was able to further determine which malformed ears were favorable for aMEI, which the Jahrsdoerfer score could not do.
CONCLUSION: The Active Middle Ear Implant Score for aural atresia (aMEI score) allows more precise risk stratification and decision making regarding the implantation. The use of operative corridors seems to have significantly better prognostic accuracy than the Jahrsdoerfer score.

Entities:  

Mesh:

Year:  2013        PMID: 23604757     DOI: 10.1007/s00234-013-1177-2

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  21 in total

1.  Facial canal anatomy in patients with microtia: evaluation of the temporal bones with thin-section CT.

Authors:  Hideki Takegoshi; Kimitaka Kaga; Shigeru Kikuchi; Ken Ito
Journal:  Radiology       Date:  2002-12       Impact factor: 11.105

2.  Fully implantable hearing aids in patients with congenital auricular atresia.

Authors:  Ralf Siegert; Stefan Mattheis; James Kasic
Journal:  Laryngoscope       Date:  2007-02       Impact factor: 3.325

3.  Treatment of mixed hearing losses via implantation of a vibratory transducer on the round window.

Authors:  Vittorio Colletti; Sigfrid D Soli; Marco Carner; L Colletti
Journal:  Int J Audiol       Date:  2006-10       Impact factor: 2.117

4.  Preoperative evaluation of the congenital aural atresia on computed tomography; an analysis of the severity of the deformity of the middle ear and mastoid.

Authors:  Mustafa Tasar; Sertac Yetiser; Duzgun Yildirim; Ugur Bozlar; M Aysin Tasar; Mutlu Saglam; M Sahin Ugurel; Bilal Battal; Taner Ucoz
Journal:  Eur J Radiol       Date:  2006-12-18       Impact factor: 3.528

5.  Middle ear dimensions in congenital aural atresia and hearing outcomes after atresiaplasty.

Authors:  Eric R Oliver; Paul R Lambert; Zoran Rumboldt; Fu-Shing Lee; Amit Agarwal
Journal:  Otol Neurotol       Date:  2010-08       Impact factor: 2.311

6.  The floating mass transducer for external auditory canal and middle ear malformations.

Authors:  Liliana Colletti; Marco Carner; Marco Mandalà; Sheila Veronese; Vittorio Colletti
Journal:  Otol Neurotol       Date:  2011-01       Impact factor: 2.311

7.  Strategies of active middle ear implants for hearing rehabilitation in congenital aural atresia.

Authors:  Nicolas Verhaert; Carine Fuchsmann; Stéphane Tringali; Geneviève Lina-Granade; Eric Truy
Journal:  Otol Neurotol       Date:  2011-06       Impact factor: 2.311

8.  The Lübeck flowchart for functional and aesthetic rehabilitation of aural atresia and microtia.

Authors:  Henning Frenzel; Reiner Schönweiler; Frauke Hanke; Armin Steffen; Barbara Wollenberg
Journal:  Otol Neurotol       Date:  2012-10       Impact factor: 2.311

9.  Application of the Vibrant Soundbridge to unilateral osseous atresia cases.

Authors:  Henning Frenzel; Frauke Hanke; Millo Beltrame; Armin Steffen; Rainer Schönweiler; Barbara Wollenberg
Journal:  Laryngoscope       Date:  2009-01       Impact factor: 3.325

10.  Congenital atresia of the external auditory canal.

Authors:  A De la Cruz; F H Linthicum; W M Luxford
Journal:  Laryngoscope       Date:  1985-04       Impact factor: 3.325

View more
  9 in total

1.  Guideline "Implantable hearing aids"-short version : German S2k guideline of the Working Group of German-Speaking Audiologists, Neurootologists and Otologists (ADANO), of the German Society of Oto-Rhino-Laryngology, Head and Neck Surgery (DGHNO) in collaboration with the German Society of Audiology (DGA), the German Society of Phoniatrics and Pediatric Audiology (DGPP), and patient representatives.

Authors:  D Beutner; W Delb; H Frenzel; U Hoppe; K B Hüttenbrink; R Mlynski; A Limberger; R Schönweiler; B Schwab; I Todt; M Walger; T Wesarg; T Zahnert; R Zeh
Journal:  HNO       Date:  2018-07       Impact factor: 1.284

2.  [Guideline "Implantable hearing aids"-short version : German S2k guideline of the Working Group of German-speaking Audiologists, Neurootologists and Otologists (ADANO), of the German Society of Oto-Rhino-Laryngology, Head and Neck Surgery (DGHNO) in collaboration with the German Society of Audiology (DGA), the German Society of Phoniatrics and Pediatric Audiology (DGPP), and patient representatives].

Authors:  D Beutner; W Delb; H Frenzel; U Hoppe; K B Hüttenbrink; R Mlynski; A Limberger; R Schönweiler; B Schwab; I Todt; M Walger; T Wesarg; T Zahnert; R Zeh
Journal:  HNO       Date:  2018-09       Impact factor: 1.284

3.  Minimal Reporting Standards for Active Middle Ear Hearing Implants.

Authors:  Hannes Maier; Uwe Baumann; Wolf-Dieter Baumgartner; Dirk Beutner; Marco D Caversaccio; Thomas Keintzel; Martin Kompis; Thomas Lenarz; Astrid Magele; Torsten Mewes; Alexander Müller; Tobias Rader; Torsten Rahne; Sebastian P Schraven; Burkard Schwab; Georg Mathias Sprinzl; Bernd Strauchmann; Ingo Todt; Thomas Wesarg; Barbara Wollenberg; Stefan K Plontke
Journal:  Audiol Neurootol       Date:  2018-09-07       Impact factor: 1.854

4.  Hearing rehabilitation with single-stage bilateral vibroplasty in a child with Franceschetti syndrome.

Authors:  Sona Sargsyan; Torsten Rahne; Sabrina Kösling; Gerburg Eichler; Stefan K Plontke
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-02-07       Impact factor: 2.503

Review 5.  Active middle ear implantation: imaging in the pre-operative planning and post-operative assessment of the Vibrant SoundbridgeTM.

Authors:  Christian Burd; Irumee Pai; Steve Ej Connor
Journal:  Br J Radiol       Date:  2020-01-28       Impact factor: 3.039

6.  International Consensus Recommendations on Microtia, Aural Atresia and Functional Ear Reconstruction.

Authors:  Tian-Yu Zhang; Neil Bulstrode; Kay W Chang; Yang-Sun Cho; Henning Frenzel; Dan Jiang; Bradley W Kesser; Ralf Siegert; Jean-Michel Triglia
Journal:  J Int Adv Otol       Date:  2019-08       Impact factor: 1.017

Review 7.  [Hearing rehabilitation with the Vibrant Soundbridge in patients with congenital middle ear malformation].

Authors:  J M Hempel; A Epp; V Volgger
Journal:  HNO       Date:  2021-02-18       Impact factor: 1.284

8.  A Bone Conduction Implantable Device as a Functional Treatment Option in Unilateral Microtia with Bilateral Stapes Ankylosis: A Report of Two Cases.

Authors:  Diego Zanetti; Federica Di Berardino
Journal:  Am J Case Rep       Date:  2018-01-23

9.  Audiological results and subjective benefit of an active transcutaneous bone-conduction device in patients with congenital aural atresia.

Authors:  Veronika Volgger; Inge Teresa Schießler; Joachim Müller; Florian Schrötzlmair; Marlene Pollotzek; John Martin Hempel
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-06-26       Impact factor: 3.236

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.