Literature DB >> 23603854

Direct reconstruction and associated uncertainties of 192Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of HDR brachytherapy cervix patients.

O A Awunor1, B Dixon, C Walker.   

Abstract

This paper details a practical method for the direct reconstruction of high dose rate (192)Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of brachytherapy cervix patients. It also details the uncertainties associated with such a process. Eight Nucletron interstitial ring applicators-Ø26 mm (×4), Ø30 mm (×3) and Ø34 mm (×1), and one 60 mm intrauterine tube were used in this study. RTQA2 and XRQA2 gafchromic films were irradiated at pre-programmed dwell positions with three successive (192)Ir sources and used to derive the coordinates of the source dwell positions. The source was observed to deviate significantly from its expected position by up to 6.1 mm in all ring sizes. Significant inter applicator differences of up to 2.6 mm were observed between a subset of ring applicators. Also, the measured data were observed to differ significantly from commercially available source path models provided by Nucletron with differences of up to 3.7 mm across all ring applicator sizes. The total expanded uncertainty (k = 2) averaged over all measured dwell positions in the rings was observed to be 1.1 ± 0.1 mm (Ø26 mm and Ø30 mm rings) and 1.0 ± 0.3 mm (Ø34 mm ring) respectively, and when transferred to the treatment planning system, equated to maximum %dose changes of 1.9%, 13.2% and 1.5% at regions representative of the parametrium, lateral fornix and organs at risk respectively.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23603854     DOI: 10.1088/0031-9155/58/10/3207

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

Review 1.  Review of strategies for MRI based reconstruction of endocavitary and interstitial applicators in brachytherapy of cervical cancer.

Authors:  José Richart; Vicente Carmona-Meseguer; Teresa García-Martínez; Antonio Herreros; Antonio Otal; Santiago Pellejero; Ana Tornero-López; José Pérez-Calatayud
Journal:  Rep Pract Oncol Radiother       Date:  2018-07-23

Review 2.  Dosimetric audit in brachytherapy.

Authors:  A L Palmer; D A Bradley; A Nisbet
Journal:  Br J Radiol       Date:  2014-05-06       Impact factor: 3.039

3.  Comparison of catheter reconstruction techniques for the lunar ovoid channels of the VeneziaTM applicator.

Authors:  Jon Hansen; David Dunkerley; Kristin Bradley; Jessica Miller; Jessie Huang
Journal:  J Contemp Brachytherapy       Date:  2020-08-21

4.  Improved source path localisation in ring applicators and the clinical impact for gynecological brachytherapy.

Authors:  Irene Humer; Christian Kirisits; Daniel Berger; Petra Trnková; Richard Pötter; Nicole Nesvacil
Journal:  J Contemp Brachytherapy       Date:  2015-06-29

5.  Quality Assurance Procedures based on Dosimetric, Gamma Analysis as a Fast Reliable Tool for Commissioning Brachytherapy Treatment Planning Systems.

Authors:  Grzegorz Zwierzchowski; Grzegorz Bieleda; Janusz Skowronek
Journal:  Radiol Oncol       Date:  2017-11-29       Impact factor: 2.991

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.