| Literature DB >> 23590463 |
W J Jeon1, J H Shim, S Y Cho, S J Baek.
Abstract
The GlideScope videolaryngoscope is widely used in the management of the difficult airway. However, passing the tracheal tube through the vocal cords can be awkward, and the use of a stylet to guide insertion is recommended. This randomised controlled trial evaluated a forceps-guided tube exchanger as an alternative to the stylet to aid intubation with the GlideScope in patients undergoing anaesthesia, with a simulated difficult airway created by the application of a semi-rigid cervical collar. Data were analysed from 178 patients randomly assigned to undergo intubation using either the stylet (n = 88) or a forceps-guided tube exchanger (n = 90). All intubations were completed successfully, with first attempt rates of 93.2% using the stylet and 94.4% using the exchanger (p = 0.597). The mean (SD) intubation time was 67.8 (28.7) s in the stylet group and 66.1 (15.5) s in the forceps-guided tube exchanger group (p = 0.11). The frequency of sore throat 1 h after extubation was 34.1% in the stylet group and 2.2% in the tube exchanger group (p < 0.001); 24 h after extubation the corresponding figures were 40.0% and 11.1% (p < 0.001). Using a forceps-guided tube exchanger may offer an advantage over a stylet in guiding tracheal intubation when the GlideScope is used. AnaesthesiaEntities:
Mesh:
Year: 2013 PMID: 23590463 DOI: 10.1111/anae.12219
Source DB: PubMed Journal: Anaesthesia ISSN: 0003-2409 Impact factor: 6.955