Considerations on an automatic computed tomography tube current modulation system.

Luca Moro1, Denis Panizza, Daniela D'Ambrosio, Irene Carne.   

Abstract

The scope of this study was to evaluate the effects on radiation output and image noise varying the acquisition parameters with an automatic tube current modulation (ATCM) system in computed tomography (CT). Chest CT examinations of an anthropomorphic phantom were acquired using a GE LightSpeed VCT 64-slice tomograph. Acquisitions were performed using different pitch, slice thickness and noise index (NI) values and varying the orientation of the scanned projection radiograph (SPR). The radiation output was determined by the CT dose index (CTDIvol). Image noise was evaluated measuring the standard deviation of CT numbers in several regions of interest. The radiation output was lower if the SPR was acquired in the anterior-posterior projection. The radiation dose with the posterior-anterior SPR was higher, because the divergence of the X-ray beam magnifies the anatomical structures closest to the tube, especially the spinal column, and this leads the ATCM system to estimate higher patient attenuation values and, therefore, to select higher tube current values. The NI was inversely proportional to the square root of the CTDIvol and, with fixed NI, the CTDIvol increased as the slice thickness decreased. This study suggests some important issues to use the GE ATCM system efficiently.

Entities:  

Mesh:

Year:  2013        PMID: 23584497     DOI: 10.1093/rpd/nct095

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  6 in total

1.  Investigating the CT localizer radiograph: acquisition parameters, patient centring and their combined influence on radiation dose.

Authors:  J W Lambert; S Kumar; J S Chen; Z J Wang; R G Gould; B M Yeh
Journal:  Br J Radiol       Date:  2015-01-22       Impact factor: 3.039

2.  Evaluating the impact of scan settings on automatic tube current modulation in CT using a novel phantom.

Authors:  Deborah Merzan; Patrik Nowik; Gavin Poludniowski; Robert Bujila
Journal:  Br J Radiol       Date:  2016-11-15       Impact factor: 3.039

3.  Impact of the scout view orientation on the radiation exposure and image quality in thoracic and abdominal CT.

Authors:  S Suntharalingam; A Wetter; N Guberina; J Theysohn; A Ringelstein; T Schlosser; M Forsting; K Nassenstein
Journal:  Eur Radiol       Date:  2016-03-04       Impact factor: 5.315

4.  Dosimetric changes with computed tomography automatic tube-current modulation techniques.

Authors:  Sofia Spampinato; Anna Maria Gueli; Pietro Milone; Luigi Angelo Raffaele
Journal:  Radiol Phys Technol       Date:  2018-04-06

5.  CT evaluation of living liver donor: Can 100-kVp plus iterative reconstruction protocol provide accurate liver volume and vascular anatomy for liver transplantation with reduced radiation and contrast dose?

Authors:  Morikatsu Yoshida; Daisuke Utsunomiya; Masafumi Kidoh; Hideaki Yuki; Seitaro Oda; Shinya Shiraishi; Hidekazu Yamamoto; Yukihiro Inomata; Yasuyuki Yamashita
Journal:  Medicine (Baltimore)       Date:  2017-06       Impact factor: 1.889

6.  A Projection Quality-Driven Tube Current Modulation Method in Cone-Beam CT for IGRT: Proof of Concept.

Authors:  Kuo Men; Jianrong Dai
Journal:  Technol Cancer Res Treat       Date:  2017-11-12