Literature DB >> 23568497

Dynamic iterative reconstruction for interventional 4-D C-arm CT perfusion imaging.

Michael T Manhart1, Markus Kowarschik, Andreas Fieselmann, Yu Deuerling-Zheng, Kevin Royalty, Andreas K Maier, Joachim Hornegger.   

Abstract

Tissue perfusion measurement using C-arm angiography systems capable of CT-like imaging (C-arm CT) is a novel technique with potentially high benefit for catheter guided treatment of stroke in the interventional suite. However, perfusion C-arm CT (PCCT) is challenging: the slow C-arm rotation speed only allows measuring samples of contrast time attenuation curves (TACs) every 5-6 s if reconstruction algorithms for static data are used. Furthermore, the peak values of the TACs in brain tissue typically lie in a range of 5-30 HU, thus perfusion imaging is very sensitive to noise. We present a dynamic, iterative reconstruction (DIR) approach to reconstruct TACs described by a weighted sum of basis functions. To reduce noise, a regularization technique based on joint bilateral filtering (JBF) is introduced. We evaluated the algorithm with a digital dynamic brain phantom and with data from six canine stroke models. With our dynamic approach, we achieve an average Pearson correlation (PC) of the PCCT canine blood flow maps to co-registered perfusion CT maps of 0.73. This PC is just as high as the PC achieved in a recent PCCT study, which required repeated injections and acquisitions.

Entities:  

Mesh:

Year:  2013        PMID: 23568497     DOI: 10.1109/TMI.2013.2257178

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  10 in total

1.  An Enhanced SMART-RECON Algorithm for Time-Resolved C-Arm Cone-Beam CT Imaging.

Authors:  Yinsheng Li; John W Garrett; Ke Li; Charles Strother; Guang-Hong Chen
Journal:  IEEE Trans Med Imaging       Date:  2019-12-20       Impact factor: 10.048

2.  Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction.

Authors:  Joris M Niesten; Irene C van der Schaaf; Alan J Riordan; Hugo W A M de Jong; Alexander D Horsch; Daniel Eijspaart; Ewoud J Smit; Willem P T M Mali; Birgitta K Velthuis
Journal:  Eur Radiol       Date:  2013-10-15       Impact factor: 5.315

3.  Maximum a posteriori signal recovery for optical coherence tomography angiography image generation and denoising.

Authors:  Lennart Husvogt; Stefan B Ploner; Siyu Chen; Daniel Stromer; Julia Schottenhamml; A Yasin Alibhai; Eric Moult; Nadia K Waheed; James G Fujimoto; Andreas Maier
Journal:  Biomed Opt Express       Date:  2020-12-07       Impact factor: 3.732

4.  Reconstruction of scalar and vectorial components in X-ray dark-field tomography.

Authors:  Florian L Bayer; Shiyang Hu; Andreas Maier; Thomas Weber; Gisela Anton; Thilo Michel; Christian P Riess
Journal:  Proc Natl Acad Sci U S A       Date:  2014-08-18       Impact factor: 11.205

5.  Statistical properties of cerebral CT perfusion imaging systems. Part I. Cerebral blood volume maps generated from nondeconvolution-based systems.

Authors:  Ke Li; Charles M Strother; Guang-Hong Chen
Journal:  Med Phys       Date:  2019-09-20       Impact factor: 4.071

6.  Inferring CT perfusion parameters and uncertainties using a Bayesian approach.

Authors:  Tao Sun; Roger Fulton; Zhanli Hu; Christina Sutiono; Dong Liang; Hairong Zheng
Journal:  Quant Imaging Med Surg       Date:  2022-01

7.  Low-dose cerebral perfusion computed tomography image restoration via low-rank and total variation regularizations.

Authors:  Shanzhou Niu; Shanli Zhang; Jing Huang; Zhaoying Bian; Wufan Chen; Gaohang Yu; Zhengrong Liang; Jianhua Ma
Journal:  Neurocomputing       Date:  2016-03-28       Impact factor: 5.719

8.  Three-dimensional regions-of-interest-based intra-operative four-dimensional soft tissue perfusion imaging using a standard x-ray system with no gantry rotation: A simulation study for a proof of concept.

Authors:  Katsuyuki Taguchi; Thomas J Sauer; W Paul Segars; Eric C Frey; Jingyan Xu; Eleni Liapi; J Webster Stayman; Kelvin Hong; Ferdinand K Hui; Mathias Unberath; Yong Du
Journal:  Med Phys       Date:  2020-10-22       Impact factor: 4.071

9.  Low-Dose Dynamic Cerebral Perfusion Computed Tomography Reconstruction via Kronecker-Basis-Representation Tensor Sparsity Regularization.

Authors:  Dong Zeng; Qi Xie; Wenfei Cao; Jiahui Lin; Hao Zhang; Shanli Zhang; Jing Huang; Zhaoying Bian; Deyu Meng; Zongben Xu; Zhengrong Liang; Wufan Chen; Jianhua Ma
Journal:  IEEE Trans Med Imaging       Date:  2017-09-04       Impact factor: 10.048

10.  Using Flat-Panel Perfusion Imaging to Measure Cerebral Hemodynamics: A Pilot Feasibility Study in Patients With Carotid Stenosis.

Authors:  Chung-Jung Lin; Wan-Yuo Guo; Feng-Chi Chang; Sheng-Che Hung; Ko-Kung Chen; Deuerling-Zheng Yu; Chun-Hsien Frank Wu; Jy-Kang Adrian Liou
Journal:  Medicine (Baltimore)       Date:  2016-05       Impact factor: 1.889

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.