Literature DB >> 33520377

Maximum a posteriori signal recovery for optical coherence tomography angiography image generation and denoising.

Lennart Husvogt1,2, Stefan B Ploner1, Siyu Chen2, Daniel Stromer1,2, Julia Schottenhamml1, A Yasin Alibhai3, Eric Moult2, Nadia K Waheed3, James G Fujimoto2, Andreas Maier1.   

Abstract

Optical coherence tomography angiography (OCTA) is a novel and clinically promising imaging modality to image retinal and sub-retinal vasculature. Based on repeated optical coherence tomography (OCT) scans, intensity changes are observed over time and used to compute OCTA image data. OCTA data are prone to noise and artifacts caused by variations in flow speed and patient movement. We propose a novel iterative maximum a posteriori signal recovery algorithm in order to generate OCTA volumes with reduced noise and increased image quality. This algorithm is based on previous work on probabilistic OCTA signal models and maximum likelihood estimates. Reconstruction results using total variation minimization and wavelet shrinkage for regularization were compared against an OCTA ground truth volume, merged from six co-registered single OCTA volumes. The results show a significant improvement in peak signal-to-noise ratio and structural similarity. The presented algorithm brings together OCTA image generation and Bayesian statistics and can be developed into new OCTA image generation and denoising algorithms.
© 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.

Entities:  

Year:  2020        PMID: 33520377      PMCID: PMC7818957          DOI: 10.1364/BOE.408903

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  17 in total

1.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

2.  General Bayesian estimation for speckle noise reduction in optical coherence tomography retinal imagery.

Authors:  Alexander Wong; Akshaya Mishra; Kostadinka Bizheva; David A Clausi
Journal:  Opt Express       Date:  2010-04-12       Impact factor: 3.894

3.  Ultrahigh-Speed, Swept-Source Optical Coherence Tomography Angiography in Nonexudative Age-Related Macular Degeneration with Geographic Atrophy.

Authors:  WooJhon Choi; Eric M Moult; Nadia K Waheed; Mehreen Adhi; ByungKun Lee; Chen D Lu; Talisa E de Carlo; Vijaysekhar Jayaraman; Philip J Rosenfeld; Jay S Duker; James G Fujimoto
Journal:  Ophthalmology       Date:  2015-10-17       Impact factor: 12.079

4.  Adaptive wavelet thresholding for image denoising and compression.

Authors:  S G Chang; B Yu; M Vetterli
Journal:  IEEE Trans Image Process       Date:  2000       Impact factor: 10.856

5.  scikit-image: image processing in Python.

Authors:  Stéfan van der Walt; Johannes L Schönberger; Juan Nunez-Iglesias; François Boulogne; Joshua D Warner; Neil Yager; Emmanuelle Gouillart; Tony Yu
Journal:  PeerJ       Date:  2014-06-19       Impact factor: 2.984

6.  An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach.

Authors:  Christoph Neukirchen; Marco Giordano; Steffen Wiesner
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

7.  Efficient and high accuracy 3-D OCT angiography motion correction in pathology.

Authors:  Stefan B Ploner; Martin F Kraus; Eric M Moult; Lennart Husvogt; Julia Schottenhamml; A Yasin Alibhai; Nadia K Waheed; Jay S Duker; James G Fujimoto; Andreas K Maier
Journal:  Biomed Opt Express       Date:  2020-12-08       Impact factor: 3.732

8.  Dynamic iterative reconstruction for interventional 4-D C-arm CT perfusion imaging.

Authors:  Michael T Manhart; Markus Kowarschik; Andreas Fieselmann; Yu Deuerling-Zheng; Kevin Royalty; Andreas K Maier; Joachim Hornegger
Journal:  IEEE Trans Med Imaging       Date:  2013-04-05       Impact factor: 10.048

9.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization.

Authors:  Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2008-08-13       Impact factor: 3.609

10.  Motion correction in optical coherence tomography volumes on a per A-scan basis using orthogonal scan patterns.

Authors:  Martin F Kraus; Benjamin Potsaid; Markus A Mayer; Ruediger Bock; Bernhard Baumann; Jonathan J Liu; Joachim Hornegger; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2012-05-03       Impact factor: 3.732

View more
  1 in total

Review 1.  The Development and Clinical Application of Innovative Optical Ophthalmic Imaging Techniques.

Authors:  Palaiologos Alexopoulos; Chisom Madu; Gadi Wollstein; Joel S Schuman
Journal:  Front Med (Lausanne)       Date:  2022-06-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.