Literature DB >> 31487396

Statistical properties of cerebral CT perfusion imaging systems. Part I. Cerebral blood volume maps generated from nondeconvolution-based systems.

Ke Li1,2, Charles M Strother2, Guang-Hong Chen1,2.   

Abstract

PURPOSE: The development and clinical employment of a computed tomography (CT) imaging system benefit from a thorough understanding of the statistical properties of the output images; cerebral CT perfusion (CTP) imaging system is no exception. A series of articles will present statistical properties of CTP systems and the dependence of these properties on system parameters. This Part I paper focuses on the signal and noise properties of cerebral blood volume (CBV) maps calculated using a nondeconvolution-based method.
METHODS: The CBV imaging chain was decomposed into a cascade of subimaging stages, which facilitated the derivation of analytical models for the probability density function, mean value, and noise variance of CBV. These models directly take CTP source image acquisition, reconstruction, and postprocessing parameters as inputs. Both numerical simulations and in vivo canine experiments were performed to validate these models.
RESULTS: The noise variance of CBV is linearly related to the noise variance of source images and is strongly influenced by the noise variance of the baseline images. Uniformly partitioning the total radiation dose budget across all time frames was found to be suboptimal, and an optimal dose partition method was derived to minimize CBV noise. Results of the numerical simulation and animal studies validated the derived statistical properties of CBV.
CONCLUSIONS: The statistical properties of CBV imaging systems can be accurately modeled by extending the linear CT systems theory. Based on the statistical model, several key signal and noise characteristics of CBV were identified and an optimal dose partition method was developed to improve the image quality of CBV.
© 2019 American Association of Physicists in Medicine.

Entities:  

Keywords:  CT image quality; CT perfusion; cascaded systems analysis; cerebral blood volume; linear systems theory; stroke imaging

Mesh:

Year:  2019        PMID: 31487396      PMCID: PMC7299080          DOI: 10.1002/mp.13806

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  46 in total

1.  Does perfusion imaging add value compared with plain parenchymal and vascular imaging?

Authors:  Guangming Zhu; Tudor Jovin; Amin Aghaebrahim; Patrik Michel; Weiwei Zhang; Max Wintermark
Journal:  J Neurointerv Surg       Date:  2012-07       Impact factor: 5.836

2.  Imaging of acute stroke and transient ischaemic attack.

Authors:  K W Muir; C Santosh
Journal:  J Neurol Neurosurg Psychiatry       Date:  2005-09       Impact factor: 10.154

Review 3.  Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke, part 1: Theoretic basis.

Authors:  A A Konstas; G V Goldmakher; T-Y Lee; M H Lev
Journal:  AJNR Am J Neuroradiol       Date:  2009-03-06       Impact factor: 3.825

Review 4.  An update on brain imaging in transient ischemic attack.

Authors:  R Souillard-Scemama; M Tisserand; D Calvet; D Jumadilova; S Lion; G Turc; M Edjlali; C Mellerio; C Lamy; O Naggara; J-F Meder; C Oppenheim
Journal:  J Neuroradiol       Date:  2015-01-31       Impact factor: 3.447

5.  Pre-intervention cerebral blood volume predicts outcomes in patients undergoing endovascular therapy for acute ischemic stroke.

Authors:  Ansaar T Rai; Karthikram Raghuram; Jeffrey S Carpenter; Jennifer Domico; Gerald Hobbs
Journal:  J Neurointerv Surg       Date:  2012-03-20       Impact factor: 5.836

6.  The effect of varying user-selected input parameters on quantitative values in CT perfusion maps.

Authors:  Pina C Sanelli; Michael H Lev; James D Eastwood; R Gilberto Gonzalez; Ting Y Lee
Journal:  Acad Radiol       Date:  2004-10       Impact factor: 3.173

7.  Stent-retriever thrombectomy after intravenous t-PA vs. t-PA alone in stroke.

Authors:  Jeffrey L Saver; Mayank Goyal; Alain Bonafe; Hans-Christoph Diener; Elad I Levy; Vitor M Pereira; Gregory W Albers; Christophe Cognard; David J Cohen; Werner Hacke; Olav Jansen; Tudor G Jovin; Heinrich P Mattle; Raul G Nogueira; Adnan H Siddiqui; Dileep R Yavagal; Blaise W Baxter; Thomas G Devlin; Demetrius K Lopes; Vivek K Reddy; Richard du Mesnil de Rochemont; Oliver C Singer; Reza Jahan
Journal:  N Engl J Med       Date:  2015-04-17       Impact factor: 91.245

8.  Endovascular therapy for ischemic stroke with perfusion-imaging selection.

Authors:  Bruce C V Campbell; Peter J Mitchell; Timothy J Kleinig; Helen M Dewey; Leonid Churilov; Nawaf Yassi; Bernard Yan; Richard J Dowling; Mark W Parsons; Thomas J Oxley; Teddy Y Wu; Mark Brooks; Marion A Simpson; Ferdinand Miteff; Christopher R Levi; Martin Krause; Timothy J Harrington; Kenneth C Faulder; Brendan S Steinfort; Miriam Priglinger; Timothy Ang; Rebecca Scroop; P Alan Barber; Ben McGuinness; Tissa Wijeratne; Thanh G Phan; Winston Chong; Ronil V Chandra; Christopher F Bladin; Monica Badve; Henry Rice; Laetitia de Villiers; Henry Ma; Patricia M Desmond; Geoffrey A Donnan; Stephen M Davis
Journal:  N Engl J Med       Date:  2015-02-11       Impact factor: 91.245

9.  Deconvolution-Based CT and MR Brain Perfusion Measurement: Theoretical Model Revisited and Practical Implementation Details.

Authors:  Andreas Fieselmann; Markus Kowarschik; Arundhuti Ganguly; Joachim Hornegger; Rebecca Fahrig
Journal:  Int J Biomed Imaging       Date:  2011-08-28

10.  Role of CT perfusion imaging in evaluating the effects of multiple burr hole surgery on adult ischemic Moyamoya disease.

Authors:  Dong Wei Dai; Wen Yuan Zhao; Yong Wei Zhang; Zhi Gang Yang; Qiang Li; Bing Xu; Xiao Long Ma; Bing Tian; Jian Min Liu
Journal:  Neuroradiology       Date:  2013-10-24       Impact factor: 2.804

View more
  3 in total

1.  [Nonlocal low-rank and sparse matrix decomposition for low-dose cerebral perfusion CT image restoration].

Authors:  S Niu; H Liu; P Liu; M Zhang; S Li; L Liang; N Li; G Liu
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2022-09-20

2.  Statistical properties of cerebral CT perfusion imaging systems. Part II. Deconvolution-based systems.

Authors:  Ke Li; Guang-Hong Chen
Journal:  Med Phys       Date:  2019-09-23       Impact factor: 4.071

3.  Leveraging non-contrast head CT to improve the image quality of cerebral CT perfusion maps.

Authors:  Evan C Harvey; Ke Li
Journal:  J Med Imaging (Bellingham)       Date:  2020-12-22
  3 in total