Literature DB >> 23555465

Magnetic resonance angiography of the aorta.

Yasuo Takehara1, Shuhei Yamashita, Harumi Sakahara, Takayuki Masui, Haruo Isoda.   

Abstract

Magnetic resonance angiography (MRA) is capable of imaging arteries in the half to whole body by a single acquisition without a nephrotoxic contrast medium, and acquired images can be reconstructed into a specific cross-sectional view in an arbitrary directions. MRA is applicable for vessels non-reachable by a catheter approach, and collateral vessels can be fully visualized. Since MRA is minimally-invasive with no exposure to ionized radiation, it can be repeatedly applied for follow-up. However, there are also disadvantages: the temporal and spatial resolutions are inferior to those of X-ray angiography, and, at present, it cannot be used as a guide for intervention. Moreover, gadolinium administrations may cause NSF in patients who have lost renal function, as a new risk. Accordingly, strict consideration is required for an indication of its application. Development of non-contrast MRA and evaluation of the wall itself may draw more attention in the future. Plaque imaging is being routinely performed nowadays, and the measurement of vascular wall shear stress, which has a close association with arteriosclerosis, may become possible by utilizing the time-resolved phase-contrast method capable of measuring the time-resolved velocity vectors of blood flow throughout the body. (*English Translation of J Jpn Coll Angiol, 2009, 49: 503-516.).

Entities:  

Keywords:  atherosclerosis; contrast-enhanced MRA; flow analysis; non-contrast MRA

Year:  2011        PMID: 23555465      PMCID: PMC3614387          DOI: 10.3400/avd.di.11.00822

Source DB:  PubMed          Journal:  Ann Vasc Dis        ISSN: 1881-641X


  24 in total

1.  Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo.

Authors:  M Miyazaki; S Sugiura; F Tateishi; H Wada; Y Kassai; H Abe
Journal:  J Magn Reson Imaging       Date:  2000-11       Impact factor: 4.813

2.  Multislice double inversion pulse sequence for efficient black-blood MRI.

Authors:  Hee Kwon Song; Alexander C Wright; Ronald L Wolf; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

3.  Verification of lumbar vertebral bodies.

Authors:  M D Ralston; T A Dykes; B I Applebaum
Journal:  Radiology       Date:  1992-11       Impact factor: 11.105

4.  Hemodynamic shear stress and its role in atherosclerosis.

Authors:  A M Malek; S L Alper; S Izumo
Journal:  JAMA       Date:  1999-12-01       Impact factor: 56.272

5.  Visualization of hemodynamics in intracranial arteries using time-resolved three-dimensional phase-contrast MRI.

Authors:  Shuhei Yamashita; Haruo Isoda; Masaya Hirano; Hiroyasu Takeda; Shoichi Inagawa; Yasuo Takehara; Marcus T Alley; Michael Markl; Norbert J Pelc; Harumi Sakahara
Journal:  J Magn Reson Imaging       Date:  2007-03       Impact factor: 4.813

Review 6.  Are gadolinium-based contrast media really safer than iodinated media for digital subtraction angiography in patients with azotemia?

Authors:  Ulf Nyman; Barbara Elmståhl; Peter Leander; Mats Nilsson; Klaes Golman; Torsten Almén
Journal:  Radiology       Date:  2002-05       Impact factor: 11.105

7.  High-dose gadodiamide for catheter angiography and CT in patients with varying degrees of renal insufficiency: Prevalence of subsequent nephrogenic systemic fibrosis and decline in renal function.

Authors:  Mellena D Bridges; Brandon S St Amant; Rebecca B McNeil; Joseph G Cernigliaro; Jamie P Dwyer; Peter M Fitzpatrick
Journal:  AJR Am J Roentgenol       Date:  2009-06       Impact factor: 3.959

Review 8.  Guidelines for the treatment of abdominal aortic aneurysms. Report of a subcommittee of the Joint Council of the American Association for Vascular Surgery and Society for Vascular Surgery.

Authors:  David C Brewster; Jack L Cronenwett; John W Hallett; K Wayne Johnston; William C Krupski; Jon S Matsumura
Journal:  J Vasc Surg       Date:  2003-05       Impact factor: 4.268

9.  Abdominal aorta and renal artery stenosis: evaluation with MR angiography.

Authors:  D Kim; R R Edelman; K C Kent; D H Porter; J J Skillman
Journal:  Radiology       Date:  1990-03       Impact factor: 11.105

10.  Radiation fibrosis: differentiation from recurrent tumor by MR imaging.

Authors:  H S Glazer; J K Lee; R G Levitt; J P Heiken; D Ling; W G Totty; D M Balfe; B Emani; T H Wasserman; W A Murphy
Journal:  Radiology       Date:  1985-09       Impact factor: 11.105

View more
  1 in total

Review 1.  Postoperative imaging of the aorta.

Authors:  Weier Li; Sasiprapa Rongthong; Anand M Prabhakar; Sandeep Hedgire
Journal:  Cardiovasc Diagn Ther       Date:  2018-04
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.