Literature DB >> 23552667

The attic of the femoral tunnel in anterior cruciate ligament reconstruction: a comparison of outcomes of two suspensory femoral fixation systems.

Ahmet Firat1, Faruk Catma, Birol Tunc, Ciğdem Hacihafizoglu, Murat Altay, Murat Bozkurt, Mehmet Ismail S Kapicioglu.   

Abstract

PURPOSE: This study aimed to find answers to the following questions: (1) Is it possible to determine and measure the space between the top of the graft and entrance of implant tunnel by magnetic resonance imaging (MRI)? (2) Is there any correlation between the hole above the graft in femoral tunnel and the femoral tunnel widening? (3) Does the tunnel widening affect clinical outcomes? (4) Are clinical and radiological outcomes of Toggle Loc with Zip Loop implant-loop design better than Endobutton CL?
METHODS: The operative data of two surgeons were analysed. One surgeon used Endobutton CL femoral fixation (E-CL group, n = 46); the other used Toggle Loc with Zip Loop femoral fixation (TL-ZL group, n = 32). At the last follow-up, clinical evaluation was performed with International Knee Documentation Committee Subjective Knee Form (IKDC), Tegner activity scale, Lysholm score, active and passive ROM, Lachman and pivot shift tests, and KT-1000 arthrometer. Radiological evaluation including measurement of tunnel widening on X-ray and MRI and the height of attic of femoral tunnel (space above the graft in femoral tunnel) on MRI was performed.
RESULTS: No difference was found in patient demographics, concomitant meniscal surgery and clinical outcomes. The femoral tunnel widening was evaluated significantly low in TL-ZL group on the PA X-ray and MRI. No difference was observed in the tibial tunnel widening on X-ray and MRI. A correlation between the height of attic of femoral tunnel and the femoral tunnel widening was determined. Thus, the greater the height of attic of femoral tunnel, the greater the femoral tunnel widening. No correlation was established between the tunnel widening and IKDC and Lysholm scores.
CONCLUSIONS: The results of this study demonstrate that a positive correlation exists between the height of the attic of the femoral tunnel and femoral tunnel widening. Therefore, increasing the height of the attic of the femoral tunnel may contribute to graft motion, which would then enhance femoral tunnel widening. LEVEL OF EVIDENCE: III.

Entities:  

Mesh:

Year:  2013        PMID: 23552667     DOI: 10.1007/s00167-013-2486-z

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  33 in total

1.  A prospective evaluation of tunnel enlargement in anterior cruciate ligament reconstruction with hamstrings: extracortical versus anatomical fixation.

Authors:  J-U Buelow; R Siebold; A Ellermann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2002-02-27       Impact factor: 4.342

2.  Pressure-induced periprosthetic osteolysis: a rat model.

Authors:  R Skripitz; P Aspenberg
Journal:  J Orthop Res       Date:  2000-05       Impact factor: 3.494

3.  The effect of outlet fixation on tunnel widening.

Authors:  F Alan Barber; Bryan Spruill; Maryann Sheluga
Journal:  Arthroscopy       Date:  2003 May-Jun       Impact factor: 4.772

4.  Analysis of tunnel widening after double-bundle ACL reconstruction.

Authors:  Yong Seuk Lee; Sheen-Woo Lee; Shin Woo Nam; Won Seok Oh; Jae Ang Sim; Ji Hoon Kwak; Beom Koo Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-15       Impact factor: 4.342

Review 5.  Treatment of anterior cruciate ligament injuries, part 2.

Authors:  Bruce D Beynnon; Robert J Johnson; Joseph A Abate; Braden C Fleming; Claude E Nichols
Journal:  Am J Sports Med       Date:  2005-11       Impact factor: 6.202

Review 6.  Bone tunnel enlargement after anterior cruciate ligament reconstruction: fact or fiction?

Authors:  J Höher; H D Möller; F H Fu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1998       Impact factor: 4.342

7.  Relation of tunnel enlargement and tunnel placement after single-bundle anterior cruciate ligament reconstruction.

Authors:  Yan Xu; Yingfang Ao; Jianquan Wang; Jiakuo Yu; Guoqing Cui
Journal:  Arthroscopy       Date:  2011-05-31       Impact factor: 4.772

8.  Tunnel widening after anterior cruciate ligament reconstruction: a prospective randomized computed tomography--based study comparing 2 different femoral fixation methods for hamstring graft.

Authors:  Dhananjaya Sabat; Kundan Kundu; Sumit Arora; Vinod Kumar
Journal:  Arthroscopy       Date:  2011-06       Impact factor: 4.772

9.  Bone-patellar tendon-bone autograft versus hamstring autograft anterior cruciate ligament reconstruction in the young athlete: a retrospective matched analysis with 2-10 year follow-up.

Authors:  Randy Mascarenhas; Michael J Tranovich; Eric J Kropf; Freddie H Fu; Christopher D Harner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-03       Impact factor: 4.342

10.  Tendon healing in a bone tunnel differs at the tunnel entrance versus the tunnel exit: an effect of graft-tunnel motion?

Authors:  Scott A Rodeo; Sumito Kawamura; Hyon-Jeong Kim; Christian Dynybil; Liang Ying
Journal:  Am J Sports Med       Date:  2006-07-21       Impact factor: 6.202

View more
  12 in total

1.  ACL hamstring grafts fixed using adjustable cortical suspension in both the femur and tibia demonstrate healing and integration on MRI at one year.

Authors:  Sven Putnis; Thomas Neri; Samuel Grasso; James Linklater; Brett Fritsch; David Parker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-17       Impact factor: 4.342

2.  A survey on prognosis of anterior cruciate ligament (ACL) reconstruction surgeries following fixed loop and adjustable loop methods.

Authors:  Pedram Yavari; Ghasem Mohammadsharifi; Behrooz Fadaei; Sina Talebi; Morteza Akbari
Journal:  Int J Physiol Pathophysiol Pharmacol       Date:  2020-12-15

3.  Adjustable-loop implants are non-inferior to fixed-loop implants for femoral fixation in anterior cruciate ligament reconstruction.

Authors:  Simone B Elmholt; Torsten G Nielsen; Martin Lind
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-06-23       Impact factor: 4.342

4.  Evaluation of Tibial Fixation Devices for Quadrupled Hamstring ACL Reconstruction.

Authors:  Elias Ammann; Andreas Hecker; Elias Bachmann; Jess G Snedeker; Sandro F Fucentese
Journal:  Orthop J Sports Med       Date:  2022-05-11

Review 5.  Fixed-loop vs. adjustable-loop cortical button devices for femoral fixation in ACL reconstruction - a systematic review and meta-analysis.

Authors:  Simone Birkebæk Elmholt; Torsten Grønbech Nielsen; Martin Lind
Journal:  J Exp Orthop       Date:  2022-10-21

6.  Graft isometry during anatomical ACL reconstruction has little effect on surgical outcomes.

Authors:  Hyun-Soo Moon; Chong-Hyuk Choi; Je-Hyun Yoo; Min Jung; Tae-Ho Lee; Kee-Bum Hong; Sung-Hwan Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-07-15       Impact factor: 4.342

7.  Passive Knee Stability After Anterior Cruciate Ligament Reconstruction Using the Endobutton or ToggleLoc With ZipLoop as a Femoral Fixation Device: A Comparison of 1654 Patients From the Danish Knee Ligament Reconstruction Registry.

Authors:  Christian Asmus Peter Asmussen; Mikkel Lindegaard Attrup; Kristian Thorborg; Per Hölmich
Journal:  Orthop J Sports Med       Date:  2018-06-14

Review 8.  Adjustable Loop Femoral Cortical Suspension Devices for Anterior Cruciate Ligament Reconstruction: A Systematic Review.

Authors:  Sarvpreet Singh; Shalin Shaunak; Sebastian C K Shaw; John L Anderson; Vipul Mandalia
Journal:  Indian J Orthop       Date:  2020-01-13       Impact factor: 1.251

9.  Efficacy of Osteoconductive Ceramics in Bioresorbable Screws for Anterior Cruciate Ligament Reconstruction: A Prospective Intrapatient Comparative Study.

Authors:  Johannes Barth; Panagiotis Akritopoulos; Nicolas Graveleau; Renaud Barthelemy; Cécile Toanen; Mo Saffarini
Journal:  Orthop J Sports Med       Date:  2016-05-31

10.  Clinical and Functional Outcomes of Anterior Cruciate Ligament Reconstruction at a Minimum of 2 Years Using Adjustable Suspensory Fixation in Both the Femur and Tibia: A Prospective Study.

Authors:  Philippe Colombet; Mo Saffarini; Nicolas Bouguennec
Journal:  Orthop J Sports Med       Date:  2018-10-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.