Literature DB >> 23550553

Evaluation of the mean absolute glucose change as a measure of glycemic variability using continuous glucose monitoring data.

Klaus-Dieter Kohnert1, Peter Heinke, Gert Fritzsche, Lutz Vogt, Petra Augstein, Eckhard Salzsieder.   

Abstract

BACKGROUND: The mean absolute glucose (MAG) change, originally developed to assess associations between glycemic variability (GV) and intensive care unit mortality, has not yet been validated. We used continuous glucose monitoring (CGM) datasets from patients with diabetes to assess the validity of MAG and to quantify associations with established measures of GV. SUBJECTS AND METHODS: Validation was based on retrospective analysis of 72-h CGM data collected during clinical studies involving 815 outpatients (48 with type 1 diabetes and 767 with type 2 diabetes). Measures of GV included SD around the sensor glucose, interquartile range, mean amplitude of glycemic excursions, and the continuous overlapping net glycemic action indices at 1, 3, and 6 h. MAG was calculated using 5-min, 60-min, and seven-point glucose profile sampling intervals; correlations among the variability measures and effects of sampling frequency were assessed.
RESULTS: Strong linear correlations between MAG change and classical markers of GV were documented (r=0.587-0.809, P<0.001 for all), whereas correlations with both glycosylated hemoglobin and mean sensor glucose were found to be weak (r=0.246 and r=0.378, respectively). The magnitude of MAG change decreased in a nonlinear fashion (P<0.001), as intervals between glucose measurements increased. MAG change, as calculated from 5-min sensor glucose readings, did reflect relatively small differences in glucose fluctuations associated with glycemic treatment modality.
CONCLUSIONS: MAG change represents a valid GV index if closely spaced sensor glucose measurements are used, but does not provide any advantage over variability indices already used for assessing diabetes control.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23550553     DOI: 10.1089/dia.2012.0303

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  15 in total

1.  Assessment of Glucose Control Metrics by Discriminant Ratio.

Authors:  Vanessa Moscardó; Pau Herrero; Monika Reddy; Nathan R Hill; Pantelis Georgiou; Nick Oliver
Journal:  Diabetes Technol Ther       Date:  2020-10       Impact factor: 6.118

2.  Test-retest reliability of a continuous glucose monitoring system in individuals with type 2 diabetes.

Authors:  Tasuku Terada; Sarah Loehr; Emmanuel Guigard; Linda J McCargar; Gordon J Bell; Peter Senior; Normand G Boulé
Journal:  Diabetes Technol Ther       Date:  2014-05-09       Impact factor: 6.118

Review 3.  Utility of different glycemic control metrics for optimizing management of diabetes.

Authors:  Klaus-Dieter Kohnert; Peter Heinke; Lutz Vogt; Eckhard Salzsieder
Journal:  World J Diabetes       Date:  2015-02-15

4.  Glycemic Variability Percentage: A Novel Method for Assessing Glycemic Variability from Continuous Glucose Monitor Data.

Authors:  Thomas A Peyser; Andrew K Balo; Bruce A Buckingham; Irl B Hirsch; Arturo Garcia
Journal:  Diabetes Technol Ther       Date:  2017-12-11       Impact factor: 6.118

5.  Sensitivity of Traditional and Risk-Based Glycemic Variability Measures to the Effect of Glucose-Lowering Treatment in Type 2 Diabetes Mellitus.

Authors:  Boris Kovatchev; Guillermo Umpierrez; Andres DiGenio; Rong Zhou; Silvio E Inzucchi
Journal:  J Diabetes Sci Technol       Date:  2015-06-15

Review 6.  Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.

Authors:  David Rodbard
Journal:  Diabetes Technol Ther       Date:  2017-06       Impact factor: 6.118

7.  Accuracy of Continuous Glucose Monitoring Measurements in Normo-Glycemic Individuals.

Authors:  Abimbola A Akintola; Raymond Noordam; Steffy W Jansen; Anton J de Craen; Bart E Ballieux; Christa M Cobbaert; Simon P Mooijaart; Hanno Pijl; Rudi G Westendorp; Diana van Heemst
Journal:  PLoS One       Date:  2015-10-07       Impact factor: 3.240

8.  Defining the target value of the coefficient of variation by continuous glucose monitoring in Chinese people with diabetes.

Authors:  Yifei Mo; Xiaojing Ma; Jingyi Lu; Yun Shen; Yufei Wang; Lei Zhang; Wei Lu; Wei Zhu; Yuqian Bao; Jian Zhou
Journal:  J Diabetes Investig       Date:  2020-11-27       Impact factor: 4.232

9.  Factors Associated with Glycemic Variability in Patients with Type 2 Diabetes: Focus on Oral Hypoglycemic Agents and Cardiovascular Risk Factors.

Authors:  Soyeon Yoo; Sang Ouk Chin; Sang Ah Lee; Gwanpyo Koh
Journal:  Endocrinol Metab (Seoul)       Date:  2015-08-04

10.  Impact of Real-Time Continuous Glucose Monitoring Use on Glucose Variability and Endothelial Function in Adolescents with Type 1 Diabetes: New Technology--New Possibility to Decrease Cardiovascular Risk?

Authors:  Milena Jamiołkowska; Izabela Jamiołkowska; Włodzimierz Łuczyński; Joanna Tołwińska; Artur Bossowski; Barbara Głowińska Olszewska
Journal:  J Diabetes Res       Date:  2015-11-16       Impact factor: 4.011

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.