Literature DB >> 23549887

Coherent plane wave compounding for very high frame rate ultrasonography of rapidly moving targets.

Bastien Denarie1, Thor Andreas Tangen, Ingvild Kinn Ekroll, Natale Rolim, Hans Torp, Tore Bjåstad, Lasse Lovstakken.   

Abstract

Coherent plane wave compounding is a promising technique for achieving very high frame rate imaging without compromising image quality or penetration. However, this approach relies on the hypothesis that the imaged object is not moving during the compounded scan sequence, which is not the case in cardiovascular imaging. This work investigates the effect of tissue motion on retrospective transmit focusing in coherent compounded plane wave imaging (PWI). Two compound scan sequences were studied based on a linear and alternating sequence of tilted plane waves, with different timing characteristics. Simulation studies revealed potentially severe degradations in the retrospective focusing process, where both radial and lateral resolution was reduced, lateral shifts of the imaged medium were introduced, and losses in signal-to-noise ratio (SNR) were inferred. For myocardial imaging, physiological tissue displacements were on the order of half a wavelength, leading to SNR losses up to 35 dB, and reductions of contrast by 40 dB. No significant difference was observed between the different tilt sequences. A motion compensation technique based on cross-correlation was introduced, which significantly recovered the losses in SNR and contrast for physiological tissue velocities. Worst case losses in SNR and contrast were recovered by 35 dB and 27-35 dB, respectively. The effects of motion were demonstrated in vivo when imaging a rat heart. Using PWI, very high frame rates up to 463 fps were achieved at high image quality, but a motion correction scheme was then required.

Entities:  

Mesh:

Year:  2013        PMID: 23549887     DOI: 10.1109/TMI.2013.2255310

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  20 in total

1.  Non-invasive Small Vessel Imaging of Human Thyroid Using Motion-Corrected Spatiotemporal Clutter Filtering.

Authors:  Rohit Nayak; Viksit Kumar; Jeremy Webb; Mostafa Fatemi; Azra Alizad
Journal:  Ultrasound Med Biol       Date:  2019-02-02       Impact factor: 2.998

2.  Pulse wave imaging using coherent compounding in a phantom and in vivo.

Authors:  Iason Zacharias Apostolakis; Matthew D J McGarry; Ethan A Bunting; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2016-12-21       Impact factor: 3.609

3.  Coherent Multi-Transducer Ultrasound Imaging.

Authors:  Laura Peralta; Alberto Gomez; Ying Luan; Bae-Hyung Kim; Joseph V Hajnal; Robert J Eckersley
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-06-05       Impact factor: 2.725

4.  High contrast power Doppler imaging in side-viewing intravascular ultrasound imaging via angular compounding.

Authors:  Graham C Collins; Bowen Jing; Brooks D Lindsey
Journal:  Ultrasonics       Date:  2020-06-02       Impact factor: 2.890

5.  Adaptive background noise bias suppression in contrast-free ultrasound microvascular imaging.

Authors:  Rohit Nayak; Mostafa Fatemi; Azra Alizad
Journal:  Phys Med Biol       Date:  2019-12-19       Impact factor: 3.609

6.  Visualizing Angle-Independent Principal Strains in the Longitudinal View of the Carotid Artery: Phantom and In Vivo Evaluation.

Authors:  Rohit Nayak; Giovanni Schifitto; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2018-04-22       Impact factor: 2.998

7.  Distributing Synthetic Focusing Over Multiple Push-Detect Events Enhances Shear Wave Elasticity Imaging Performance.

Authors:  Rifat Ahmed; Marvin M Doyley
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-04-12       Impact factor: 2.725

8.  Cardiac Strain Imaging With Coherent Compounding of Diverging Waves.

Authors:  Julien Grondin; Vincent Sayseng; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-06-20       Impact factor: 2.725

9.  Optimization of Transmit Parameters in Cardiac Strain Imaging With Full and Partial Aperture Coherent Compounding.

Authors:  Vincent Sayseng; Julien Grondin; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-05       Impact factor: 2.725

10.  Leveraging the Imaging Transmit Pulse to Manipulate Phase-Change Nanodroplets for Contrast-Enhanced Ultrasound.

Authors:  Yiying I Zhu; Heechul Yoon; Andrew X Zhao; Stanislav Y Emelianov
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-01-25       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.