Literature DB >> 2353649

Validation and applications of mitral prosthetic valvular areas calculated by Doppler echocardiography.

J G Dumesnil1, G N Honos, M Lemieux, J Beauchemin.   

Abstract

Doppler echocardiography is used in the noninvasive evaluation of mitral valve prostheses using parameters heretofore validated primarily for native valves. Accordingly, this study was designed to examine the validity and relative usefulness of valve gradient and area measurements in a group of 26 patients (17 women, 9 men, mean age 62 +/- 8 years), 19 +/- 4 months after implantation of different sizes (25 to 31 mm) of a given type of bioprosthesis. Areas obtained with both the continuity equation, using stroke volume measured in the left ventricular outflow tract, and the pressure half-time method are compared to known prosthetic areas derived from an in vitro hydraulic model. Areas calculated by the continuity equation correlate well with in vitro areas (r = 0.82, standard error of the y estimate = 0.1 cm2, p less than 0.001), and are within the range of predicted in vitro values in 92% of cases. Areas derived by the pressure half-time method do not correlate with in vitro areas (r = 0.15, p greater than 0.3) or continuity equation areas (r = 0.23, p greater than 0.2), and are above the range of predicted values in 69% of cases. Correlations are also found between continuity equation areas and the peak and mean valvular gradients (r = 0.59, p less than 0.005 and r = -0.63, p less than 0.0005, respectively). Taking the effect of cardiac output on gradients into account results in projected relations between indexed prosthetic areas and the pressure gradients at rest and during exercise.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1990        PMID: 2353649     DOI: 10.1016/0002-9149(90)91352-7

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  13 in total

Review 1.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

2.  The Quebec Heart Institute: 50 years of excellence in cardiology.

Authors:  Gilles R Dagenais; François Philippon; Jean-Pierre Després; Jean G Dumesnil; Paul Cartier; Peter M Bogaty; Michel Lemieux; André Moisan
Journal:  Can J Cardiol       Date:  2007-10       Impact factor: 5.223

Review 3.  Prosthesis-patient mismatch: an update.

Authors:  Jean G Dumesnil; Philippe Pibarot
Journal:  Curr Cardiol Rep       Date:  2011-06       Impact factor: 2.931

4.  Patient-prosthesis mismatch in the mitral position affects midterm survival and functional status.

Authors:  Denis Bouchard; Frédéric Vanden Eynden; Philippe Demers; Louis P Perrault; Michel Carrier; Raymond Cartier; Arsène J Basmadjian; Michel Pellerin
Journal:  Can J Cardiol       Date:  2010-12       Impact factor: 5.223

5.  Doppler sonographic evaluation of mechanical and bioprosthetic mitral valve prostheses during exercise with a rate corrected pressure half time.

Authors:  P Weiss; A Hoffmann; D Burckhardt
Journal:  Br Heart J       Date:  1992-06

6.  Assessment of mitral bioprostheses using cardiovascular magnetic resonance.

Authors:  Florian von Knobelsdorff-Brenkenhoff; André Rudolph; Ralf Wassmuth; Jeanette Schulz-Menger
Journal:  J Cardiovasc Magn Reson       Date:  2010-06-23       Impact factor: 5.364

7.  [Imaging following valve replacement].

Authors:  D Dabir; E Arroyo-Ucar; E A Ucar; E Nagel
Journal:  Radiologe       Date:  2013-10       Impact factor: 0.635

8.  Weight gain potential-a neglected entity during valve replacement.

Authors:  Vijayanand Palanisamy; Karthik Raman; Anjith Prakash Rajakumar; Anbarasu Mohanraj; Jacob Jamesraj; Ejaz Ahmed Sheriff; Valikapthalil Mathew Kurian; Rajan Sethuratnam
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-07-19

Review 9.  Echocardiographic Assessment of Heart Valve Prostheses.

Authors:  Chiara Sordelli; Sergio Severino; Luigi Ascione; Pasquale Coppolino; Pio Caso
Journal:  J Cardiovasc Echogr       Date:  2014 Oct-Dec

10.  Functional assessment of bioprosthetic mitral valves by cardiovascular magnetic resonance: An in vitro validation and comparison to Doppler echocardiography.

Authors:  Dimitrios Maragiannis; Matthew S Jackson; Kyle Autry; Jose H Flores Arredondo; Constantina Aggeli; Dimitrios Tousoulis; William A Zoghbi; Dipan J Shah; Stephen H Little
Journal:  J Cardiovasc Magn Reson       Date:  2020-07-30       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.