Wear comparison between conventional and highly cross-linked polyethylene against a zirconia head: a concise follow-up, at an average 10 years, of a previous report.

Kiyokazu Fukui1, Ayumi Kaneuji, Tanzo Sugimori, Toru Ichiseki, Tadami Matsumoto.   

Abstract

We previously reported the results of wear comparison at a minimum of 5 years between highly cross-linked polyethylene (HXLPE) and conventional polyethylene (PE) against a zirconia femoral head. We now report the mean wear at 10 years for 52 patients (56 hips) of the original cohort of 61 patients (65 hips) who had undergone primary total hip arthroplasty at our hospital between November 1999 and August 2000. The mean steady-state linear wear rate of HXLPE was 0.045 mm/y, compared with 0.080 mm/y for conventional PE (P=.0003). The incidence of osteolysis was 25% in the conventional PE group compared with 0% in the HXLPE group. Our study demonstrated that the steady-state wear rate for HXLPE remains significantly lower than that for conventional PE against a zirconia femoral head at a mean of 10 years after implantation.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  conventional polyethylene; highly cross-linked polyethylene; steady-state wear; zirconia femoral head

Mesh:

Substances:

Year:  2013        PMID: 23523499     DOI: 10.1016/j.arth.2012.12.020

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Highly Crosslinked Polyethylene Liners Have Negligible Wear at 10 Years: A Radiostereometric Analysis Study.

Authors:  David G Campbell; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2022-03-01       Impact factor: 4.755

2.  Gender Differences in Wear Rates for 28- vs 32-mm Ceramic Femoral Heads on Modern Highly Cross-linked Polyethylene at Midterm Follow-Up in Young Patients Undergoing Total Hip Arthroplasty.

Authors:  Jeffrey B Stambough; Gail Pashos; Ningying Wu; Jacob A Haynes; John M Martell; John C Clohisy
Journal:  J Arthroplasty       Date:  2015-10-28       Impact factor: 4.757

3.  Long-Term Results of Total Hip Arthroplasty with 28-Millimeter Cobalt-Chromium Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years and Less.

Authors:  Jeffrey B Stambough; Gail Pashos; Frank C Bohnenkamp; William J Maloney; John M Martell; John C Clohisy
Journal:  J Arthroplasty       Date:  2015-07-17       Impact factor: 4.757

4.  Contemporary ceramic total hip arthroplasty in patients with cerebral palsy: does it work?

Authors:  Byung-Ho Yoon; Young-Kyun Lee; Yong-Chan Ha; Kyung-Hoi Koo
Journal:  Clin Orthop Surg       Date:  2015-02-10

5.  The Current Concepts of Total Hip Arthroplasty.

Authors:  Joong-Myung Lee
Journal:  Hip Pelvis       Date:  2016-12-28

6.  Quantitative Measurements of Backside Wear in Acetabular Hip Joint Replacement: Conventional Polyethylene Versus Cross-Linked Polyethylene.

Authors:  Steffen Braun; Sebastian Jaeger; Robert Sonntag; Stefan Schroeder; J Philippe Kretzer
Journal:  Materials (Basel)       Date:  2020-04-15       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.