Comparison of the mechanical properties of rotary instruments made of conventional nickel-titanium wire, M-wire, or nickel-titanium alloy in R-phase.

Hélio P Lopes1, Thaiane Gambarra-Soares, Carlos N Elias, José F Siqueira, Inês F J Inojosa, Weber S P Lopes, Victor T L Vieira.   

Abstract

INTRODUCTION: This study compared the mechanical properties of endodontic instruments made of conventional nickel-titanium (NiTi) wire (K(3) and Revo-S SU), M-Wire (ProFile Vortex), or NiTi alloy in R-phase (K(3)XF).
METHODS: The test instruments were subjected to mechanical tests to evaluate resistance to bending (flexibility), cyclic fatigue, and torsional load in clockwise rotation. Data were statistically evaluated by the analysis of variance test and the Student-Newman-Keuls test for multiple comparisons.
RESULTS: In the bending resistance test, flexibility decreased in the following order: K(3)XF > Revo-S SU > ProFile Vortex > K(3). The ranking in the fatigue resistance test was the following: K(3)XF > K(3) > ProFile Vortex > Revo-S SU. In the torsional assay, the angular deflection at failure decreased in the following order: K(3)XF > Revo-S SU > K(3) > ProFile Vortex. For the maximum torque values, the ranking was K(3) > K(3)XF > ProFile Vortex > Revo-S SU.
CONCLUSIONS: The results showed that the K(3)XF instrument, which is made of NiTi alloy in R-phase, had the overall best performance in terms of flexibility, angular deflection at failure, and cyclic fatigue resistance. In addition to the alloy from which the instrument is manufactured, the design and dimensions are important determinants of the mechanical performance of endodontic instruments.
Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23522548     DOI: 10.1016/j.joen.2012.12.006

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  18 in total

1.  Both operator and heat treatment determine the centring ability of Reciproc® files in vitro.

Authors:  N Hofmann
Journal:  Clin Oral Investig       Date:  2018-05-12       Impact factor: 3.573

2.  Cyclic fatigue and torsional strength of three different thermally treated reciprocating nickel-titanium instruments.

Authors:  Murilo Priori Alcalde; Marco Antonio Hungaro Duarte; Clovis Monteiro Bramante; Bruno Carvalho de Vasconselos; Mario Tanomaru-Filho; Juliane Maria Guerreiro-Tanomaru; Jader Camilo Pinto; Marcus Vinicius Reis Só; Rodrigo Ricci Vivan
Journal:  Clin Oral Investig       Date:  2017-12-09       Impact factor: 3.573

3.  Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments.

Authors:  Emmanuel João Nogueira Leal Silva; Victor Talarico Leal Vieira; Fernanda Hecksher; Marja Ribeiro Silva Dos Santos Oliveira; Henrique Dos Santos Antunes; Edson Jorge Lima Moreira
Journal:  Clin Oral Investig       Date:  2018-02-01       Impact factor: 3.573

4.  Cyclic fatigue resistance of D-RaCe, ProTaper, and Mtwo nickel-titanium retreatment instruments after immersion in sodium hypochlorite.

Authors:  Hüseyin Sinan Topçuoğlu; Kanşad Pala; Ahmet Aktı; Salih Düzgün; Gamze Topçuoğlu
Journal:  Clin Oral Investig       Date:  2015-09-30       Impact factor: 3.573

5.  Danger zone analysis using cone beam computed tomography after apical enlargement with K3 and K3XF in a manikin model.

Authors:  Juan-Gonzalo Olivier; Marc García-Font; Jose-Antonio Gonzalez-Sanchez; Miguel Roig-Cayon; Fernando Durán-Sindreu
Journal:  J Clin Exp Dent       Date:  2016-10-01

6.  Bending resistance and cyclic fatigue life of Reciproc Blue, WaveOne Gold, and Genius files in a double (S-shaped) curved canal.

Authors:  Taha Özyürek; Mustafa Gündoğar; Koray Yılmaz; Gülşah Uslu
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-12-13

7.  Occurence of dentinal defects after root canal preparation with R-phase, M-Wire and Gold Wire instruments: a micro-CT analysis.

Authors:  Marcely Cassimiro; Kaline Romeiro; Luciana Gominho; Andressa de Almeida; Larissa Costa; Diana Albuquerque
Journal:  BMC Oral Health       Date:  2017-06-02       Impact factor: 2.757

8.  Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography.

Authors:  Iussif Mamede-Neto; Alvaro Henrique Borges; Orlando Aguirre Guedes; Durvalino de Oliveira; Fábio Luis Miranda Pedro; Carlos Estrela
Journal:  Open Dent J       Date:  2017-02-14

9.  Cyclic Fatigue Resistance and Force Generated by OneShape Instruments during Curved Canal Preparation.

Authors:  Zhuyu Wang; Wen Zhang; Xiaolei Zhang
Journal:  PLoS One       Date:  2016-08-11       Impact factor: 3.240

10.  Fracture Resistance of K3 Nickel-Titanium Files Made from Different Thermal Treatments.

Authors:  JinWook Choi; Soram Oh; Yu-Chan Kim; Kwang-Koo Jee; KeeYeon Kum; SeokWoo Chang
Journal:  Bioinorg Chem Appl       Date:  2016-11-14       Impact factor: 7.778

View more