Literature DB >> 23515989

Fixation, survival, and dislocation of jumbo acetabular components in revision hip arthroplasty.

Paul F Lachiewicz1, Elizabeth S Soileau.   

Abstract

BACKGROUND: Acetabular revision of a total hip arthroplasty using jumbo components (Mayo definition, ≥62 mm in women and ≥66 mm in men) offers distinct advantages in patients with notable acetabular bone loss. However, there are little data on the long-term survival and complications associated with use of these components.
METHODS: This retrospective study of prospectively collected data included 120 patients who underwent 129 revision total hip arthroplasties with jumbo cups. Data on infection, aseptic loosening, reoperation, and dislocation were analyzed. One hundred and one patients (108 hips) with a mean follow-up of 8.1 years (range, two to twenty years) were evaluated with use of the Harris hip score and radiographic evidence of loosening, radiolucent lines, and osteolysis. Kaplan-Meier survivorship was calculated at ten and fifteen years with use of three different end points. Demographic and operative factors associated with implant survival and dislocation were analyzed with use of chi-square and Wilcoxon tests.
RESULTS: Four (3.1%) of the jumbo components were removed for infection and four hips (3.1%) had aseptic implant loosening. Reoperation for any reason was performed in twenty hips. With failure defined as cup revision for aseptic loosening or radiographic evidence of loosening, implant survival was 97.3% (95% confidence interval [CI], 89.6% to 99.3%) at ten years and 82.8% (95% CI, 59% to 97.6%) at fifteen years. With failure defined as cup removal for any reason, implant survival was 93.8% (95% CI, 83.4% to 97.2%) at ten years and 79.8% (95% CI, 61.1% to 95.4%) at fifteen years. There was no significant association between Paprosky type, component coating, or patient characteristics and failure. Dislocation occurred in twelve (9.3%) of the hips (10% of the patients) and three underwent reoperation. A femoral head size of ≥32 mm was associated with a significantly lower risk of dislocation compared with smaller sizes.
CONCLUSIONS: Jumbo acetabular components with screw fixation were associated with low rates of infection and loosening after revision total hip arthroplasty and had high survival at fifteen years. Reoperation for wear and loosening increased in the second decade. Dislocation was the most common complication and was significantly associated with smaller femoral head sizes.

Entities:  

Mesh:

Year:  2013        PMID: 23515989     DOI: 10.2106/JBJS.L.00758

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  19 in total

1.  Do jumbo cups cause hip center elevation in revision THA? A computer simulation.

Authors:  Chima Nwankwo; Nick N Dong; Christopher D Heffernan; Michael D Ries
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

2.  What is the survivorship of fully coated femoral components in revision hip arthroplasty?

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

3.  Do revision total hip augments provide appropriate modularity?

Authors:  Matthew G Teeter; Douglas D R Naudie; James L Howard; Richard W McCalden; Steven J MacDonald
Journal:  Can J Surg       Date:  2015-02       Impact factor: 2.089

4.  Long-term clinical outcome of acetabular cup revision surgery: comparison of cemented cups, cementless cups, and cemented cups with reinforcement devices.

Authors:  Yasuo Kokubo; Hisashi Oki; Daisuke Sugita; Kohei Negoro; Kenichi Takeno; Tsuyoshi Miyazaki; Hideaki Nakajima
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-03-24

5.  Tantalum Components in Difficult Acetabular Revisions Have Good Survival at 5 to 10 Years: Longer Term Followup of a Previous Report.

Authors:  Paul F Lachiewicz; Jane Anne O'Dell
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

6.  Modular revision strategy with bispherical augments in severe acetabular deficiency reconstruction.

Authors:  Guo-Yuan Li; Xiao-Qi Zhang; Min Chen; Zheng-Liang Luo; Xiao-Feng Ji; Xi-Fu Shang
Journal:  Int Orthop       Date:  2021-08-27       Impact factor: 3.075

7.  Do jumbo cups cause hip center elevation in revision THA? A radiographic evaluation.

Authors:  Chima D Nwankwo; Michael D Ries
Journal:  Clin Orthop Relat Res       Date:  2014-04-18       Impact factor: 4.176

8.  Tritanium acetabular wedge augments: short-term results.

Authors:  Camilo Restrepo; Snir Heller; Antonia F Chen
Journal:  Ann Transl Med       Date:  2016-06

9.  Cementless jumbo cups for revision of failed Furlong prosthesis. A case series.

Authors:  Ahmed Salem Eid; Ahmed Kotb; Waleed Elshabrawy
Journal:  J Clin Orthop Trauma       Date:  2018-08-11

10.  [Short-term effectiveness of acetabular reconstruction with three-dimensional printed trabecular metal pads in hip revision].

Authors:  Zhongyuan Zhang; Jinwei Zhao; Xiangjie Huang; Hexun Jiang; Ziyao Xu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-12-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.