Literature DB >> 23503044

Telephone-based re-education on the day before colonoscopy improves the quality of bowel preparation and the polyp detection rate: a prospective, colonoscopist-blinded, randomised, controlled study.

Xiaodong Liu1, Hui Luo, Lin Zhang, Felix W Leung, Zhiguo Liu, Xiangping Wang, Rui Huang, Na Hui, Kaichun Wu, Daiming Fan, Yanglin Pan, Xuegang Guo.   

Abstract

BACKGROUND: Despite advances in bowel preparation methods, the quality of bowel preparation in some patients undergoing colonoscopy remains unsatisfactory. The effect of telephone re-education (TRE) on the day before colonoscopy on the quality of bowel preparation and other outcome measures had not been studied.
METHODS: A prospective colonoscopist-blinded study was conducted. All patients received regular instructions during a visit to discuss colonoscopy. Those scheduled for colonoscopy were randomly assigned to receive TRE on the day before colonoscopy (TRE group) for bowel preparation or no TRE (control group). The primary outcome was the rate of adequate bowel preparation. The secondary outcomes included polyp detection rate (PDR), non-compliance with instructions, and willingness to repeat bowel preparation.
RESULTS: A total of 605 patients were randomised, 305 to the TRE group and 300 to the control group. In an intention-to-treat analysis of the primary outcome, adequate preparation was found in 81.6% vs 70.3% of TRE and control patients, respectively (p=0.001). PDR was 38.0% vs 24.7% in the TRE and control group, respectively (p<0.001). Among patients with successful colonoscopy, the Ottawa scores were 3.0±2.3 in the TRE group and 4.9±3.2 in the control group (p<0.001). Fewer patients who showed non-compliance with instructions were found in the TRE group (9.4% vs 32.6%, p<0.001). No significant differences were observed between the two groups with regard to willingness to have a repeat bowel preparation (p=0.409).
CONCLUSIONS: TRE about the details of bowel preparation on the day before colonoscopy significantly improved the quality of bowel preparation and PDR.

Entities:  

Keywords:  COLONOSCOPY

Mesh:

Substances:

Year:  2013        PMID: 23503044     DOI: 10.1136/gutjnl-2012-304292

Source DB:  PubMed          Journal:  Gut        ISSN: 0017-5749            Impact factor:   23.059


  58 in total

1.  Screening colonoscopy bowel preparation: experience in an urban minority population.

Authors:  Corey H Basch; Charles E Basch; Randi L Wolf; Patricia Zybert; Benjamin Lebwohl; Celia Shmukler; Alfred I Neugut; Steven Shea
Journal:  Therap Adv Gastroenterol       Date:  2013-11       Impact factor: 4.409

2.  Relationship between health literacy and quality of colonoscopy bowel preparation.

Authors:  Umut Eren Erdoğdu; Hacı Murat Çaycı; Ali Tardu; Ufuk Arslan; Hakan Demirci; Çınar Yıldırım
Journal:  Turk J Gastroenterol       Date:  2020-11       Impact factor: 1.852

3.  Risk Factors Associated with Inadequate Bowel Preparation in Patients with Functional Constipation.

Authors:  Xiaoyang Guo; Xin Shi; Xiaoyu Kang; Hui Luo; Xiangping Wang; Hui Jia; Qin Tao; Jingjie Wang; Mingxin Zhang; Jinhai Wang; Xiaolan Lu; Shiyang Ma; Tao Lin; Yujie Jing; Yanglin Pan; Xuegang Guo; Daiming Fan
Journal:  Dig Dis Sci       Date:  2019-10-12       Impact factor: 3.199

4.  Patient factors that affect quality of colonoscopy preparation.

Authors:  Marina Serper; Andrew J Gawron; Samuel G Smith; Anjali A Pandit; Allison R Dahlke; Elizabeth A Bojarski; Rajesh N Keswani; Michael S Wolf
Journal:  Clin Gastroenterol Hepatol       Date:  2013-08-15       Impact factor: 11.382

5.  Same-Day Single Dose of 2 Liter Polyethylene Glycol is Not Inferior to The Standard Bowel Preparation Regimen in Low-Risk Patients: A Randomized, Controlled Trial.

Authors:  Xiaoyu Kang; Lina Zhao; Zhiyong Zhu; Felix Leung; Limei Wang; Xiangping Wang; Hui Luo; Linhui Zhang; Tao Dong; Pingying Li; Zhangqin Chen; Gui Ren; Hui Jia; Xiaoyang Guo; Yanglin Pan; Xuegang Guo; Daiming Fan
Journal:  Am J Gastroenterol       Date:  2018-03-13       Impact factor: 10.864

6.  Predictors of Suboptimal Bowel Preparation Using 3-l of Polyethylene Glycol for an Outpatient Colonoscopy: A Prospective Observational Study.

Authors:  Chi-Liang Cheng; Nai-Jen Liu; Jui-Hsiang Tang; Yen-Lin Kuo; Hsiang-Ling Hung; Yi-Ning Tsui; Bai-Ping Lee; Cheng-Hui Lin
Journal:  Dig Dis Sci       Date:  2016-10-21       Impact factor: 3.199

Review 7.  Advances in image enhancement in colonoscopy for detection of adenomas.

Authors:  Takahisa Matsuda; Akiko Ono; Masau Sekiguchi; Takahiro Fujii; Yutaka Saito
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2017-03-15       Impact factor: 46.802

8.  Risk factors for inadequate colonoscopy bowel preparations in African Americans and whites at an urban medical center.

Authors:  Anoop Appannagari; Shikha Mangla; Chuanhong Liao; K Gautham Reddy; Sonia S Kupfer
Journal:  South Med J       Date:  2014-04       Impact factor: 0.954

9.  The Secondary Quality Indicator to Improve Prediction of Adenoma Miss Rate Apart from Adenoma Detection Rate.

Authors:  Satimai Aniwan; Piyachai Orkoonsawat; Vichai Viriyautsahakul; Phonthep Angsuwatcharakon; Rapat Pittayanon; Naruemon Wisedopas; Sakolkun Sumdin; Yuwadee Ponuthai; Sumitra Wiangngoen; Pinit Kullavanijaya; Rungsun Rerknimitr
Journal:  Am J Gastroenterol       Date:  2016-01-26       Impact factor: 10.864

10.  Withdrawal time in excellent or very poor bowel preparation qualities.

Authors:  David Widjaja; Manoj Bhandari; Vivian Loveday-Laghi; Mariela Glandt; Bhavna Balar
Journal:  World J Gastrointest Endosc       Date:  2014-05-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.