Effect of alignment changes on sagittal and coronal socket reaction moment interactions in transtibial prostheses.

Toshiki Kobayashi1, Michael S Orendurff, Ming Zhang, David A Boone.   

Abstract

Alignment is important for comfortable and stable gait of lower-limb prosthesis users. The magnitude of socket reaction moments in the multiple planes acting simultaneously upon the residual limb may be related to perception of comfort in individuals using prostheses through socket interface pressures. The aim of this study was to investigate the effect of prosthetic alignment changes on sagittal and coronal socket reaction moment interactions (moment-moment curves) and to characterize the curves in 11 individuals with transtibial amputation using novel moment-moment interaction parameters measured by plotting sagittal socket reaction moments versus coronal ones under various alignment conditions. A custom instrumented prosthesis alignment component was used to measure socket reaction moments during walking. Prosthetic alignment was tuned to a nominally aligned condition by a prosthetist, and from this position, angular (3° and 6° of flexion, extension, abduction or adduction of the socket) and translational (5mm and 10mm of anterior, posterior, medial or lateral translation of the socket) alignment changes were performed in either the sagittal or the coronal plane in a randomized manner. A total of 17 alignment conditions were tested. Coronal angulation and translation alignment changes demonstrated similar consistent changes in the moment-moment curves. Sagittal alignment changes demonstrated more complex changes compared to the coronal alignment changes. Effect of sagittal angulations and translations on the moment-moment curves was different during 2nd rocker (mid-stance) with extension malalignment appearing to cause medio-lateral instability. Presentation of coronal and sagittal socket reaction moment interactions may provide useful visual information for prosthetists to understand the biomechanical effects of malalignment of transtibial prostheses.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Mesh:

Year:  2013        PMID: 23499228     DOI: 10.1016/j.jbiomech.2013.01.026

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  8 in total

1.  Effect of prosthetic alignment changes on socket reaction moment impulse during walking in transtibial amputees.

Authors:  Toshiki Kobayashi; Michael S Orendurff; Adam K Arabian; Teri G Rosenbaum-Chou; David A Boone
Journal:  J Biomech       Date:  2014-02-14       Impact factor: 2.712

2.  Effect of alignment changes on socket reaction moments while walking in transtibial prostheses with energy storage and return feet.

Authors:  Toshiki Kobayashi; Adam K Arabian; Michael S Orendurff; Teri G Rosenbaum-Chou; David A Boone
Journal:  Clin Biomech (Bristol, Avon)       Date:  2013-11-13       Impact factor: 2.063

3.  Effect of alignment changes on socket reaction moments during gait in transfemoral and knee-disarticulation prostheses: case series.

Authors:  Toshiki Kobayashi; Michael S Orendurff; David A Boone
Journal:  J Biomech       Date:  2013-07-26       Impact factor: 2.712

Review 4.  The Effect of Alignment Changes on Unilateral Transtibial Amputee's Gait: A Systematic Review.

Authors:  Niels Jonkergouw; Maarten R Prins; Arjan W P Buis; Peter van der Wurff
Journal:  PLoS One       Date:  2016-12-06       Impact factor: 3.240

5.  The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation.

Authors:  Hiroshi Hashimoto; Toshiki Kobayashi; Fan Gao; Masataka Kataoka; Kuniharu Okuda
Journal:  J Rehabil Assist Technol Eng       Date:  2018-11-18

Review 6.  Review of the socket design and interface pressure measurement for transtibial prosthesis.

Authors:  Gh Pirouzi; N A Abu Osman; A Eshraghi; S Ali; H Gholizadeh; W A B Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-13

7.  The relationship between trans-femoral prosthesis alignment and the center trajectory of plantar pressure in the frontal plane.

Authors:  Tomohiro Nomura; Kota Watanabe; Toshiya Nosaka; Hiroyuki Matsubara; Masaharu Akiyama; Kimiharu Inui
Journal:  J Phys Ther Sci       Date:  2016-02-29

8.  Proactive Locomotor Adjustments Are Specific to Perturbation Uncertainty in Below-Knee Prosthesis Users.

Authors:  Matthew J Major; Chelsi K Serba; Xinlin Chen; Nicholas Reimold; Franklyn Ndubuisi-Obi; Keith E Gordon
Journal:  Sci Rep       Date:  2018-01-30       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.