Literature DB >> 23489931

Evaluation of phase-contrast CT of breast tissue at conventional X-ray sources - presentation of selected findings.

Susanne Grandl1, Marian Willner, Julia Herzen, Doris Mayr, Sigrid D Auweter, Alexander Hipp, Franz Pfeiffer, Maximilian Reiser, Karin Hellerhoff.   

Abstract

BACKGROUND: Grating-based phase contrast computed tomography (PC-CT) at synchrotron radiation sources has been shown to provide improved visualization of breast tumors. However, broad clinical application of phase-contrast imaging will likely depend on transferring the technology to standard polychromatic X-ray sources. On the basis of selected findings, we demonstrate the potential of grating-based PC-CT using a conventional X-ray source.
MATERIALS AND METHODS: Grating-based PC-CT of two ex-vivo formalin fixed breast specimens containing lobular carcinoma was conducted using a Talbot Lau interferometer run at a polychromatic X-ray source of 40kVp. Phase-contrast and absorption-based 3D-datasets of both specimens were simultaneously recorded. Radiological images were manually matched with corresponding histological sections. The visualization of selected histological findings in phase contrast was compared to absorption contrast.
RESULTS: Grating-based PC-CT was able to depict the 3-dimensional structure of dilated ducts and high phase contrast was found as a correlate to thickened fibrous ductal walls. Differences in contrast between fibrous and less fibrous breast tissue were observed in phase- but not in absorption-contrast images. Furthermore, regions of low phase contrast correlated with the extension of compact tumor components.
CONCLUSIONS: On the basis of selected findings, we show that grating-based PC-CT at a polychromatic X-ray source provides complementary information to conventional absorption contrast; albeit at lower spatial resolution than synchrotron-based imaging.
Copyright © 2013. Published by Elsevier GmbH.

Entities:  

Keywords:  Brust; Gitterbasierte Phasenkontrast-Computertomographie; Grating-based phase contrast computed tomography; breast; invasiv lobuläres Karzinom; invasive lobular carcinoma

Mesh:

Year:  2013        PMID: 23489931     DOI: 10.1016/j.zemedi.2013.02.005

Source DB:  PubMed          Journal:  Z Med Phys        ISSN: 0939-3889            Impact factor:   4.820


  13 in total

1.  X-ray phase-contrast imaging of the breast--advances towards clinical implementation.

Authors:  S D Auweter; J Herzen; M Willner; S Grandl; K Scherer; F Bamberg; M F Reiser; F Pfeiffer; K Hellerhoff
Journal:  Br J Radiol       Date:  2014-02       Impact factor: 3.039

2.  Fast one-dimensional wave-front propagation for x-ray differential phase-contrast imaging.

Authors:  Johannes Wolf; Andreas Malecki; Jonathan Sperl; Michael Chabior; Markus Schüttler; Dirk Bequé; Cristina Cozzini; Franz Pfeiffer
Journal:  Biomed Opt Express       Date:  2014-09-29       Impact factor: 3.732

3.  Design, Construction, and Initial Results of a Prototype Multi-Contrast X-Ray Breast Imaging System.

Authors:  Ke Li; Ran Zhang; John Garrett; Yongshuai Ge; Xu Ji; Guang-Hong Chen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09

4.  High energy x-ray phase contrast CT using glancing-angle grating interferometers.

Authors:  A Sarapata; J W Stayman; M Finkenthal; J H Siewerdsen; F Pfeiffer; D Stutman
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

5.  Fast acquisition with seamless stage translation (FASST) for a trimodal x-ray breast imaging system.

Authors:  Ran Zhang; Amy M Fowler; Lee G Wilke; Frederick Kelcz; John W Garrett; Guang-Hong Chen; Ke Li
Journal:  Med Phys       Date:  2020-06-23       Impact factor: 4.071

Review 6.  Review of quantitative multiscale imaging of breast cancer.

Authors:  Michael A Pinkert; Lonie R Salkowski; Patricia J Keely; Timothy J Hall; Walter F Block; Kevin W Eliceiri
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-22

Review 7.  [Phase contrast imaging of the breast. Basic principles and steps towards clinical implementation].

Authors:  S Grandl; A Sztrókay-Gaul; S D Auweter; K Hellerhoff
Journal:  Radiologe       Date:  2014-03       Impact factor: 0.635

8.  Development and preclinical evaluation of a patient-specific high energy x-ray phase sensitive breast tomosynthesis system.

Authors:  Muhammad U Ghani; Xizeng Wu; Laurie L Fajardo; Zhengxue Jing; Molly D Wong; Bin Zheng; Farid Omoumi; Yuhua Li; Aimin Yan; Peter Jenkins; Stephen L Hillis; Laura Linstroth; Hong Liu
Journal:  Med Phys       Date:  2021-04-01       Impact factor: 4.071

9.  Quantitative assessment of murine articular cartilage and bone using X-ray phase-contrast imaging.

Authors:  Jun Li; Huihui Yuan; Mingshu Wu; Linan Dong; Lu Zhang; Hongli Shi; Shuqian Luo
Journal:  PLoS One       Date:  2014-11-04       Impact factor: 3.240

10.  Visualizing typical features of breast fibroadenomas using phase-contrast CT: an ex-vivo study.

Authors:  Susanne Grandl; Marian Willner; Julia Herzen; Anikó Sztrókay-Gaul; Doris Mayr; Sigrid D Auweter; Alexander Hipp; Lorenz Birnbacher; Mathias Marschner; Michael Chabior; Maximilian Reiser; Franz Pfeiffer; Fabian Bamberg; Karin Hellerhoff
Journal:  PLoS One       Date:  2014-05-13       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.