Literature DB >> 27207575

A microchip electrophoresis-mass spectrometric platform with double cell lysis nano-electrodes for automated single cell analysis.

Xiangtang Li1, Shulin Zhao2, Hankun Hu3, Yi-Ming Liu4.   

Abstract

Capillary electrophoresis-based single cell analysis has become an essential approach in researches at the cellular level. However, automation of single cell analysis has been a challenge due to the difficulty to control the number of cells injected and the irreproducibility associated with cell aggregation. Herein we report the development of a new microfluidic platform deploying the double nano-electrode cell lysis technique for automated analysis of single cells with mass spectrometric detection. The proposed microfluidic chip features integration of a cell-sized high voltage zone for quick single cell lysis, a microfluidic channel for electrophoretic separation, and a nanoelectrospray emitter for ionization in MS detection. Built upon this platform, a microchip electrophoresis-mass spectrometric method (MCE-MS) has been developed for automated single cell analysis. In the method, cell introduction, cell lysis, and MCE-MS separation are computer controlled and integrated as a cycle into consecutive assays. Analysis of large numbers of individual PC-12 neuronal cells (both intact and exposed to 25mM KCl) was carried out to determine intracellular levels of dopamine (DA) and glutamic acid (Glu). It was found that DA content in PC-12 cells was higher than Glu content, and both varied from cell to cell. The ratio of intracellular DA to Glu was 4.20±0.8 (n=150). Interestingly, the ratio drastically decreased to 0.38±0.20 (n=150) after the cells are exposed to 25mM KCl for 8min, suggesting the cells released DA promptly and heavily while they released Glu at a much slower pace in response to KCl-induced depolarization. These results indicate that the proposed MCE-MS analytical platform may have a great potential in researches at the cellular level.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Automation; Dopamine; Glutamic acid; Microchip electrophoresis-mass spectrometry; PC-12 cells; Single cell analysis

Mesh:

Substances:

Year:  2016        PMID: 27207575      PMCID: PMC4887279          DOI: 10.1016/j.chroma.2016.05.015

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  40 in total

1.  Microfluidic device for single-cell analysis.

Authors:  Aaron R Wheeler; William R Throndset; Rebecca J Whelan; Andrew M Leach; Richard N Zare; Yish Hann Liao; Kevin Farrell; Ian D Manger; Antoine Daridon
Journal:  Anal Chem       Date:  2003-07-15       Impact factor: 6.986

2.  Microfluidic devices for the high-throughput chemical analysis of cells.

Authors:  Maxine A McClain; Christopher T Culbertson; Stephen C Jacobson; Nancy L Allbritton; Christopher E Sims; J Michael Ramsey
Journal:  Anal Chem       Date:  2003-11-01       Impact factor: 6.986

Review 3.  Chip-based separation devices coupled to mass spectrometry.

Authors:  Stefan Ohla; Detlev Belder
Journal:  Curr Opin Chem Biol       Date:  2012-06-05       Impact factor: 8.822

4.  Feasibility of SU-8-based capillary electrophoresis-electrospray ionization mass spectrometry microfluidic chips for the analysis of human cell lysates.

Authors:  Nina Nordman; Tiina Sikanen; Susanna Aura; Santeri Tuomikoski; Katariina Vuorensola; Tapio Kotiaho; Sami Franssila; Risto Kostiainen
Journal:  Electrophoresis       Date:  2010-11       Impact factor: 3.535

5.  Sampling techniques for single-cell electrophoresis.

Authors:  Christine Cecala; Jonathan V Sweedler
Journal:  Analyst       Date:  2012-01-30       Impact factor: 4.616

6.  Microfluidic glass chips with an integrated nanospray emitter for coupling to a mass spectrometer.

Authors:  Peter Hoffmann; Ulrich Häusig; Philipp Schulze; Detlev Belder
Journal:  Angew Chem Int Ed Engl       Date:  2007       Impact factor: 15.336

Review 7.  Single-cell metabolomics: analytical and biological perspectives.

Authors:  R Zenobi
Journal:  Science       Date:  2013-12-06       Impact factor: 47.728

Review 8.  Recent advances in the combination of capillary electrophoresis with mass spectrometry: from element to single-cell analysis.

Authors:  Karel Klepárník
Journal:  Electrophoresis       Date:  2012-12-03       Impact factor: 3.535

Review 9.  Single cell optical imaging and spectroscopy.

Authors:  Anthony S Stender; Kyle Marchuk; Chang Liu; Suzanne Sander; Matthew W Meyer; Emily A Smith; Bhanu Neupane; Gufeng Wang; Junjie Li; Ji-Xin Cheng; Bo Huang; Ning Fang
Journal:  Chem Rev       Date:  2013-02-14       Impact factor: 60.622

10.  Fully integrated glass microfluidic device for performing high-efficiency capillary electrophoresis and electrospray ionization mass spectrometry.

Authors:  J S Mellors; V Gorbounov; R S Ramsey; J M Ramsey
Journal:  Anal Chem       Date:  2008-08-13       Impact factor: 6.986

View more
  5 in total

1.  Sample-to-analysis platform for rapid intracellular mass spectrometry from small numbers of cells.

Authors:  Austin L Culberson; Mason A Chilmonczyk; Peter A Kottke; Annie C Bowles-Welch; Delta Ghoshal; Andrei G Fedorov
Journal:  Lab Chip       Date:  2021-11-25       Impact factor: 6.799

Review 2.  Single cell metabolism: current and future trends.

Authors:  Ahmed Ali; Shawn Davidson; Ernest Fraenkel; Ian Gilmore; Thomas Hankemeier; Jennifer A Kirwan; Andrew N Lane; Ingela Lanekoff; Mioara Larion; Laura-Isobel McCall; Michael Murphy; Jonathan V Sweedler; Caigang Zhu
Journal:  Metabolomics       Date:  2022-10-01       Impact factor: 4.747

3.  Quantitative Approach for Protein Analysis in Small Cell Ensembles by an Integrated Microfluidic Chip with MALDI Mass Spectrometry.

Authors:  Mian Yang; Jorvani Cruz Villarreal; Nethmi Ariyasinghe; Rory Kruithoff; Robert Ros; Alexandra Ros
Journal:  Anal Chem       Date:  2021-04-05       Impact factor: 6.986

Review 4.  Microfluidics as a Novel Tool for Biological and Toxicological Assays in Drug Discovery Processes: Focus on Microchip Electrophoresis.

Authors:  Giuseppe Caruso; Nicolò Musso; Margherita Grasso; Angelita Costantino; Giuseppe Lazzarino; Fabio Tascedda; Massimo Gulisano; Susan M Lunte; Filippo Caraci
Journal:  Micromachines (Basel)       Date:  2020-06-15       Impact factor: 2.891

Review 5.  Mass spectrometry based high-throughput bioanalysis of low molecular weight compounds: are we ready to support personalized medicine?

Authors:  Sophie Bravo-Veyrat; Gérard Hopfgartner
Journal:  Anal Bioanal Chem       Date:  2021-08-23       Impact factor: 4.142

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.