Literature DB >> 23465887

Implementation of echocardiography core laboratory best practices: a case study of the PARTNER I trial.

Pamela S Douglas1, Robert A Waugh, Gerald Bloomfield, Gary Dunn, Lagia Davis, Rebecca T Hahn, Philippe Pibarot, William J Stewart, Neil J Weissman, Irene Hueter, Robert Siegel, Stamatios Lerakis, D Craig Miller, Craig R Smith, Martin B Leon.   

Abstract

BACKGROUND: Multicenter clinical trials use echocardiographic core laboratories to ensure expertise and consistency in the assessment of imaging eligibility criteria, as well as safety and efficacy end points. The aim of this study was to report the real-world implementation of guidelines for best practices in echocardiographic core laboratories, including their feasibility and quality results, in a large, international multicenter trial.
METHODS: Processes and procedures were developed to optimize the acquisition and analysis of echocardiograms for the Placement of Aortic Transcatheter Valves (PARTNER) I trial of percutaneous aortic valve replacement for aortic stenosis. Comparison of baseline findings in the operative and nonoperative cohorts and reproducibility analyses were performed.
RESULTS: Echocardiography was performed in 1,055 patients (mean age, 83 years; 54% men) The average peak and mean aortic valve gradients were 73 ± 24 and 43 ± 15 mm Hg, and the average aortic valve area was 0.64 ± 0.20 cm(2). The average ejection fraction was 52 ± 13% by visual estimation and 53 ± 14% by biplane planimetry. The mean left ventricular mass index was 151 ± 42 g/m(2). The inoperable cohort had lower left ventricular mass and mass indexes and tended to have more severe mitral regurgitation. Core lab reproducibility was excellent, with intraclass correlation coefficients ranging from 0.92 to 0.99 and κ statistics from 0.58 to 0.85 for key variables. The image acquisition quality improvement process brought measurability to >85%, which was maintained for the duration of the study.
CONCLUSIONS: This real-world echocardiographic core lab experience in the PARTNER I trial demonstrates that a high standard of measurability and reproducibility can result from extensive quality assurance efforts in both image acquisition and analysis. These results and the echocardiographic data reported here provide a reference for future studies of aortic stenosis patients and should encourage the wider use of echocardiography in clinical research.
Copyright © 2013 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23465887     DOI: 10.1016/j.echo.2013.01.013

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  18 in total

Review 1.  Guidance of transcatheter aortic valve replacement by echocardiography.

Authors:  Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

2.  Markers of Atherosclerosis, Clinical Characteristics, and Treatment Patterns in Heart Failure: A Case-Control Study of Middle-Aged Adult Heart Failure Patients in Rural Kenya.

Authors:  Gerald S Bloomfield; Allison K DeLong; Constantine O Akwanalo; Joseph W Hogan; E Jane Carter; Daniel F Aswa; Cynthia Binanay; Myra Koech; Sylvester Kimaiyo; Eric J Velazquez
Journal:  Glob Heart       Date:  2016-03

Review 3.  Paravalvular regurgitation following transcutaneous aortic valve replacement: predictors and clinical significance.

Authors:  Rebecca T Hahn; Susheel Kodali; Philippe Généreux; Martin Leon
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

4.  Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort--a analysis.

Authors:  Philippe Pibarot; Neil J Weissman; William J Stewart; Rebecca T Hahn; Brian R Lindman; Thomas McAndrew; Susheel K Kodali; Michael J Mack; Vinod H Thourani; D Craig Miller; Lars G Svensson; Howard C Herrmann; Craig R Smith; Josep Rodés-Cabau; John Webb; Scott Lim; Ke Xu; Irene Hueter; Pamela S Douglas; Martin B Leon
Journal:  J Am Coll Cardiol       Date:  2014-09-30       Impact factor: 24.094

5.  Modern Use of Echocardiography in Transcatheter Aortic Valve Replacement: an Up-Date.

Authors:  Cristina Caldararu; Serban Balanescu
Journal:  Maedica (Bucur)       Date:  2016-12

6.  Comparison of transcatheter and surgical aortic valve replacement in severe aortic stenosis: a longitudinal study of echocardiography parameters in cohort A of the PARTNER trial (placement of aortic transcatheter valves).

Authors:  Rebecca T Hahn; Philippe Pibarot; William J Stewart; Neil J Weissman; Deepika Gopalakrishnan; Martin G Keane; Saif Anwaruddin; Zuyue Wang; Martin Bilsker; Brian R Lindman; Howard C Herrmann; Susheel K Kodali; Raj Makkar; Vinod H Thourani; Lars G Svensson; Jodi J Akin; William N Anderson; Martin B Leon; Pamela S Douglas
Journal:  J Am Coll Cardiol       Date:  2013-04-23       Impact factor: 24.094

7.  Impact of Ejection Fraction and Aortic Valve Gradient on Outcomes of Transcatheter Aortic Valve Replacement.

Authors:  Suzanne J Baron; Suzanne V Arnold; Howard C Herrmann; David R Holmes; Wilson Y Szeto; Keith B Allen; Adnan K Chhatriwalla; Sreekaanth Vemulapali; Sean O'Brien; Dadi Dai; David J Cohen
Journal:  J Am Coll Cardiol       Date:  2016-05-24       Impact factor: 24.094

8.  Risk stratification in patients with pulmonary hypertension undergoing transcatheter aortic valve replacement.

Authors:  Brian R Lindman; Alan Zajarias; Hersh S Maniar; D Craig Miller; Rakesh M Suri; Suzanne V Arnold; John Webb; Lars G Svensson; Susheel Kodali; Ke Xu; Girma M Ayele; Fay Lin; Shing-Chiu Wong; Vasilis Babaliaros; Vinod H Thourani; Pamela S Douglas; Scott Lim; Martin B Leon; Michael J Mack
Journal:  Heart       Date:  2015-08-11       Impact factor: 5.994

9.  Early regression of severe left ventricular hypertrophy after transcatheter aortic valve replacement is associated with decreased hospitalizations.

Authors:  Brian R Lindman; William J Stewart; Philippe Pibarot; Rebecca T Hahn; Catherine M Otto; Ke Xu; Richard B Devereux; Neil J Weissman; Maurice Enriquez-Sarano; Wilson Y Szeto; Raj Makkar; D Craig Miller; Stamatios Lerakis; Samir Kapadia; Bruce Bowers; Kevin L Greason; Thomas C McAndrew; Yang Lei; Martin B Leon; Pamela S Douglas
Journal:  JACC Cardiovasc Interv       Date:  2014-06       Impact factor: 11.195

10.  Longitudinal Hemodynamics of Transcatheter and Surgical Aortic Valves in the PARTNER Trial.

Authors:  Pamela S Douglas; Martin B Leon; Michael J Mack; Lars G Svensson; John G Webb; Rebecca T Hahn; Philippe Pibarot; Neil J Weissman; D Craig Miller; Samir Kapadia; Howard C Herrmann; Susheel K Kodali; Raj R Makkar; Vinod H Thourani; Stamatios Lerakis; Ashley M Lowry; Jeevanantham Rajeswaran; Matthew T Finn; Maria C Alu; Craig R Smith; Eugene H Blackstone
Journal:  JAMA Cardiol       Date:  2017-11-01       Impact factor: 14.676

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.