G Heilemann1, B Poppe, W Laub. 1. Oregon Health and Science University, Portland, Oregon 97239, USA. gerd.heilemann@uni-oldenburg.de
Abstract
PURPOSE: In this study the effects of small systematic MLC misalignments and gravitational errors on the quality of Rapidarc treatment plan delivery are investigated with respect to verification measurements with two detector arrays and the evaluation of clinical significance of the error-induced deviations. METHODS: Five prostate and six head and neck plans were modified by means of three error types: (1) both MLC banks are opened, respectively, in opposing directions, resulting in larger fields; (2) both MLC banks are closed, resulting in smaller fields; and (3) both MLC banks are shifted for lateral gantry angles, respectively, in the same direction to simulate the effects of gravity on the leaves. Measurements were evaluated with respect to a gamma-index of 3%/3 mm and 2%/2 mm. Dose in the modified plans was recalculated and the resulting dose volume histograms for target and critical structures were compared to those of the unaltered plans. RESULTS: The smallest introduced leaf position deviations which fail the >90% criterion for a gamma-index of 2%/2 mm are: (1) 1 mm; (2) 0.5 mm for prostate and 1.0 mm for head and neck cases; and (3) 3 mm corresponding to the error types, respectively. These errors would lead to significant changes in mean PTV dose and would not be detected with the more commonly used 3%/3 mm gamma-index criterion. CONCLUSIONS: A stricter gamma-index (2%/2 mm) is necessary in order to detect positional errors of the MLC. Nevertheless, the quality assurance procedure of Rapidarc treatment plans must include a thorough examination of where dose discrepancies occur, and professional judgment is needed when interpreting the gamma-index analysis, since even a >90% passing rate using the 2%/2 mm gamma-index criterion does not guarantee the absence of clinically significance dose deviation.
PURPOSE: In this study the effects of small systematic MLC misalignments and gravitational errors on the quality of Rapidarc treatment plan delivery are investigated with respect to verification measurements with two detector arrays and the evaluation of clinical significance of the error-induced deviations. METHODS: Five prostate and six head and neck plans were modified by means of three error types: (1) both MLC banks are opened, respectively, in opposing directions, resulting in larger fields; (2) both MLC banks are closed, resulting in smaller fields; and (3) both MLC banks are shifted for lateral gantry angles, respectively, in the same direction to simulate the effects of gravity on the leaves. Measurements were evaluated with respect to a gamma-index of 3%/3 mm and 2%/2 mm. Dose in the modified plans was recalculated and the resulting dose volume histograms for target and critical structures were compared to those of the unaltered plans. RESULTS: The smallest introduced leaf position deviations which fail the >90% criterion for a gamma-index of 2%/2 mm are: (1) 1 mm; (2) 0.5 mm for prostate and 1.0 mm for head and neck cases; and (3) 3 mm corresponding to the error types, respectively. These errors would lead to significant changes in mean PTV dose and would not be detected with the more commonly used 3%/3 mm gamma-index criterion. CONCLUSIONS: A stricter gamma-index (2%/2 mm) is necessary in order to detect positional errors of the MLC. Nevertheless, the quality assurance procedure of Rapidarc treatment plans must include a thorough examination of where dose discrepancies occur, and professional judgment is needed when interpreting the gamma-index analysis, since even a >90% passing rate using the 2%/2 mm gamma-index criterion does not guarantee the absence of clinically significance dose deviation.
Authors: Bryce C Allred; Jie Shan; Daniel G Robertson; Todd A DeWees; Jiajian Shen; Wei Liu; Joshua B Stoker Journal: J Appl Clin Med Phys Date: 2021-03-29 Impact factor: 2.102
Authors: Young Min Moon; Sang Il Bae; Moo Jae Han; Wan Jeon; Tosol Yu; Chul Won Choi; Jin Young Kim Journal: Technol Cancer Res Treat Date: 2021 Jan-Dec
Authors: Sarah O S Osman; Prakash Jeevanandam; Nithya Kanakavelu; Denise M Irvine; Ciara A Lyons; Suneil Jain; Alan R Hounsell; Conor K McGarry Journal: Radiat Oncol Date: 2016-11-24 Impact factor: 3.481
Authors: Philipp Szeverinski; Matthias Kowatsch; Thomas Künzler; Marco Meinschad; Patrick Clemens; Alexander F DeVries Journal: J Appl Clin Med Phys Date: 2021-06-20 Impact factor: 2.102
Authors: Philipp Szeverinski; Matthias Kowatsch; Thomas Künzler; Marco Meinschad; Patrick Clemens; Alexander F DeVries Journal: J Appl Clin Med Phys Date: 2020-10-23 Impact factor: 2.243