Literature DB >> 234611

99mTc-DTPA(Sn) dry-kit preparation. Quality control and clearance studies.

V Kempi, R B Persson.   

Abstract

The preparation technique for 99m-Tc-DTPA(Sn)-complex has been studied in detail in order to find the optimal conditions for preparation. The concentration of DTPA should be at least 10 mM, and that of Sn(II) less than 1 mM, in order to obtain a reproducible high-labelling yield. A dry sterile kit was prepared of 39.3 mg H-5DTPA and 2.3 mg SnCl-2 with 2H-2O in a 10 ml vial. The 99m-Tc-DTPA(Sn) was prepared by adding the 99m-Tc-eluate to the vial. After 1 min the solution was sterile-filtered and was ready for use. The plasma clearance of 99m-Tc-DTPA(Sn) in man determined by blood-sampling up to 200 minutes after administration shows a good correlation to endogenous creatinine clearance (r plus 0.93). The plasma disappearance curve studied during 24 h is, however, a sum of three exponentials corresponding to biological half-times of 18 plus or minus 8 min, 105 plus or minus 9 min and 17 plus or minus 4 h. The slow third component representing about 2% is assumed to be due to binding of 99m-Tc to plasma proteins. The absorbed radiation dose calculated for whole body is 8 mrad/mCi, kidneys 50 mrad/mCi, bladder 300 mrad/mCi, ovaries 17 mrad/mCi and testes 11 mrad/mCi. This agent is a valuable radiopharmaceutical for renovascular clinical problems. Scintigraphic imaging of the aorta, kidneys, ureters and bladder (for residual urinary volume-determination) could be performed.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 234611

Source DB:  PubMed          Journal:  Nucl Med (Stuttg)


  8 in total

1.  A gamma camera method for quantitation of split renal function in children followed for vesicoureteric reflux.

Authors:  T E Tamminen; E J Riihimäki; E E Tähti
Journal:  Pediatr Radiol       Date:  1978-06-19

2.  Evaluation of Tc-99m-DTPA for renal clearance studies in the pig.

Authors:  C S Worthley; M J Byrne; R Hickman
Journal:  Urol Res       Date:  1988

3.  Quality control of 99mTc-radiopharmaceuticals. Evaluation of GCS minicolumns in routine clinical work with scintillation cameras.

Authors:  L Darte; B R Persson
Journal:  Eur J Nucl Med       Date:  1980-12

4.  Comparative investigations of renal scanning agents.

Authors:  W Jakubowski; W Graban; I Licińska; T Krasucki; E Lachnik; W Zulczyk; J Wiza; S Smoliński
Journal:  Eur J Nucl Med       Date:  1978

5.  Renal effect of SB 7505: a double-blind study.

Authors:  G F Melloni; G M Minoja; G Scorazzati; R Bauer; B Brusoni; P Ghirardi
Journal:  Eur J Clin Pharmacol       Date:  1981-02       Impact factor: 2.953

6.  Comparison of methods for determination of glomerular filtration rate: low and high-dose Tc-99m-DTPA renography, predicted creatinine clearance method, and plasma sample method.

Authors:  Majid Assadi; Mohammad Eftekhari; Mehrdad Hozhabrosadati; Mohsen Saghari; Abdolali Ebrahimi; Iraj Nabipour; Mohammad Zaki Abbasi; Darab Moshtaghi; Moloud Abbaszadeh; Sakineh Assadi
Journal:  Int Urol Nephrol       Date:  2008-08-09       Impact factor: 2.370

7.  Determination of glomerular filtration rate (GFR) by analysis of capillary blood after single shot injection of 99mTc-DTPA. A comparison with simultaneous 125I-iothalamate GFR estimation showing equal GFR but difference in distribution volume.

Authors:  K Rootwelt; D Falch; R Sjökvist
Journal:  Eur J Nucl Med       Date:  1980-04

8.  Evaluation of renal function parameters with simultaneously administered 99mTc-DTPA and 131I-hippuran.

Authors:  V Kempi; B R Persson
Journal:  Eur J Nucl Med       Date:  1983
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.