Literature DB >> 6341067

Evaluation of renal function parameters with simultaneously administered 99mTc-DTPA and 131I-hippuran.

V Kempi, B R Persson.   

Abstract

The present study aimed at comparing two renal function tests using 99mTc-DTPA (diethylene triamine penta acetic acid) and 131I-labeled hippuran (o-hippuric acid). A mixture of 80 MBq 99mTc-DTPA and 7.4 MBq 131I-hippuran in a total volume of 1.5 ml or less was injected into an arm-vein. Both radiopharmaceuticals have identical initial distributions in the blood pool when injected in this manner. Seventy-two patients were studied with the present dual radionuclide technique. The following parameters were derived from the renogram: area under curve, uptake ratio, Tmax, decrease ratio, excretion ratio, and rate of decrease. The parameters for 99mTc-DTPA and 131I-hippuran were compared for various kidney groups. Generally the renographic parameters were well correlated. Apart from the systematic differences due to different modes of renal excretion, the curve patterns virtually agreed. The differences that were observed between the two tracers lacked clinical significance.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6341067     DOI: 10.1007/bf00252558

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  12 in total

1.  99 Tcm-ascorbate; preparation, quality-control cand quantitative renal uptake in man.

Authors:  R B Persson; S E Strand; T White
Journal:  Int J Nucl Med Biol       Date:  1975-07

2.  SCINTILLATION CAMERA WITH MULTICHANNEL COLLIMATORS.

Authors:  H O ANGER
Journal:  J Nucl Med       Date:  1964-07       Impact factor: 10.057

3.  Evaluation of radioiodinated hipuran for the estimation of renal plasma flow.

Authors:  M K BURBANK; W N TAUXE; F T MAHER; J C HUNT
Journal:  Proc Staff Meet Mayo Clin       Date:  1961-07-19

4.  Effective plasma flow of the individual kidney. Determination on the basis of the ( 131 I)hippuran renogram.

Authors:  N Norman
Journal:  Scand J Clin Lab Invest       Date:  1972-12       Impact factor: 1.713

5.  Technetium-99m DTPA: a new radiopharmaceutical for brain and kidney scanning.

Authors:  W Hauser; H L Atkins; K G Nelson; P Richards
Journal:  Radiology       Date:  1970-03       Impact factor: 11.105

6.  99mTc-DTPA(Sn) dry-kit preparation. Quality control and clearance studies.

Authors:  V Kempi; R B Persson
Journal:  Nucl Med (Stuttg)       Date:  1975-01-31

7.  A scintillation camera technique for quantitative estimation of separate kidney function and its use before nephrectomy.

Authors:  I Larsson; E Lindstedt; P Ohlin; S E Strand; T White
Journal:  Scand J Clin Lab Invest       Date:  1975-10       Impact factor: 1.713

8.  99mTc-DTPA scintillation-camera renography: a new method for estimation of single-kidney function.

Authors:  S P Nielsen; M L Moller; J Trap-Jensen
Journal:  J Nucl Med       Date:  1977-02       Impact factor: 10.057

9.  Comparative labelling and biokinetic studies of 99mTc-EDTA(Sn) and 99mTc-DTPA(Sn).

Authors:  N Agha; R B Persson
Journal:  Nuklearmedizin       Date:  1977-02       Impact factor: 1.379

10.  Scintillation camera renography with 99mTc-DTPA and 131I-Hippuran.

Authors:  C G Bratt; I Larsson; T White
Journal:  Scand J Clin Lab Invest       Date:  1981-04       Impact factor: 1.713

View more
  1 in total

1.  Evaluation of renal function and morphology with radionuclides.

Authors:  K zum Winkel
Journal:  Eur J Nucl Med       Date:  1984
  1 in total