Literature DB >> 23456522

Radiation exposure to critical organs in panoramic dental examination.

Mohammad Taghi Bahreyni Toossi1, Fateme Akbari, Shahram Bayani Roodi.   

Abstract

Nowadays, radiography is a necessary procedure in diagnosis and treatment of patients with dental problems. According to the ALARA (as low as reasonably achievable) principle, dentists must take radiographs of sufficient quality at the lowest possible radiation dose to the patients. The assessment of patient dose on panoramic radiography is difficult because of dynamic nature of the imaging process and the narrow width of the x-ray beam. The present work describes an experiment undertaken using thermoluminescence dosimeters (TLD-100) to obtain the absorbed dose in organs and sensitive tissues in head and neck region during panoramic radiography, based on patient measurement. The overall mean entrance surface dose on thyroid, right and left lens of eyes, parotid glands (right and left) and occipital region in panoramic were 38, negligible, negligible, 367, 319 and 262 μGy, respectively. The results show that there are differences between patient doses examined by different panoramic systems. There is a tendency for lower organ doses for digital compared with analogue panoramic units.
© 2012 Tehran University of Medical Sciences. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23456522

Source DB:  PubMed          Journal:  Acta Med Iran        ISSN: 0044-6025


  3 in total

1.  TLD measurements and Monte Carlo calculations of head and neck organ and effective doses for cone beam computed tomography using 3D Accuitomo 170.

Authors:  Marina Ernst; Peter Manser; Karl Dula; Werner Volken; Marco Fm Stampanoni; Michael K Fix
Journal:  Dentomaxillofac Radiol       Date:  2017-07-27       Impact factor: 2.419

2.  Thyroid Radiation Dose to Patients from Diagnostic Radiology Procedures over Eight Decades: 1930-2010.

Authors:  Lienard A Chang; Donald L Miller; Choonsik Lee; Dunstana R Melo; Daphnée Villoing; Vladimir Drozdovitch; Isabelle Thierry-Chef; Sarah J Winters; Michael Labrake; Charles F Myers; Hyeyeun Lim; Cari M Kitahara; Martha S Linet; Steven L Simon
Journal:  Health Phys       Date:  2017-12       Impact factor: 1.316

3.  Dosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography.

Authors:  R Ghanbarnezhad Farshi; A Mesbahi; M Johari; Ü Kara; N Gharehaghaji
Journal:  J Biomed Phys Eng       Date:  2019-02-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.