Literature DB >> 23454580

Multi-Frame SPRITE: a method for resolution enhancement of multiple-point SPRITE data.

Joachim B Kaffanke1, Sandro Romanzetti, Thomas Dierkes, Martin O Leach, Bruce J Balcom, N Jon Shah.   

Abstract

The Single Point Ramped Imaging with T1 Enhancement (SPRITE) sequence is well suited for the acquisition of magnetic resonance signals from fast relaxing nuclei and from heterogeneous materials. However, it is time inefficient compared to sequences that are based on frequency encoding because only one single point is acquired per excitation. Multiple-point SPRITE (mSPRITE) mitigates this problem with the acquisition of multiple FID points. mSPRITE images reconstructed from early FID samples suffer from reduced spatial resolution due to the limited extent of its corresponding k-space. In this work we present a new reconstruction algorithm for spatial resolution enhancement that solves this problem without changes to the mSPRITE sequence. The method, called Multi-Frame mSPRITE, substitutes high spatial frequencies from late FID points into k-spaces of limited extent constructed from early FID points. In this way, images of high quality and resolution can be obtained despite a large range of zoom factors used to reconstruct images with the same FOV and resolution.
Copyright © 2013 Elsevier Inc. All rights reserved.

Mesh:

Year:  2013        PMID: 23454580     DOI: 10.1016/j.jmr.2013.01.008

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  6 in total

1.  Fully phase-encoded MRI near metallic implants using ultrashort echo times and broadband excitation.

Authors:  Curtis N Wiens; Nathan S Artz; Hyungseok Jang; Alan B McMillan; Kevin M Koch; Scott B Reeder
Journal:  Magn Reson Med       Date:  2017-08-21       Impact factor: 4.668

2.  Ramped hybrid encoding for improved ultrashort echo time imaging.

Authors:  Hyungseok Jang; Curtis N Wiens; Alan B McMillan
Journal:  Magn Reson Med       Date:  2015-09-18       Impact factor: 4.668

3.  A rapid and robust gradient measurement technique using dynamic single-point imaging.

Authors:  Hyungseok Jang; Alan B McMillan
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

4.  Single acquisition quantitative single-point electron paramagnetic resonance imaging.

Authors:  Hyungseok Jang; Sankaran Subramanian; Nallathamby Devasahayam; Keita Saito; Shingo Matsumoto; Murali C Krishna; Alan B McMillan
Journal:  Magn Reson Med       Date:  2013-08-01       Impact factor: 4.668

5.  Purely phase-encoded MRI of turbulent flow through a dysfunctional bileaflet mechanical heart valve.

Authors:  Olusegun Adegbite; Lyes Kadem; Benedict Newling
Journal:  MAGMA       Date:  2013-09-24       Impact factor: 2.310

6.  HYFI: Hybrid filling of the dead-time gap for faster zero echo time imaging.

Authors:  Romain Froidevaux; Markus Weiger; Manuela B Rösler; David O Brunner; Klaas P Pruessmann
Journal:  NMR Biomed       Date:  2021-02-23       Impact factor: 4.044

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.