Literature DB >> 18546771

The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: 6-month fatigue retention values.

Dimitrios Doukas1, George Michelinakis, Phillip W Smith, Craig W Barclay.   

Abstract

This in vitro study evaluated the 6-month fatigue retention provided by 5 paired overdenture attachments placed at 3 different interimplant distances (19, 23, and 29 mm). Mean fatigue retention was calculated for each attachment type and compared with the retention produced by the other attachments tested and the initial retention values published earlier. Interimplant distance was found to play a significant role only in the retention of the Hader bar with red and yellow clips. A significant reduction in retention values was observed for 4 of 5 attachment types.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18546771

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  12 in total

1.  An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures.

Authors:  Abdalbseet A Fatalla; Ke Song; Tianfeng Du; Yingguang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2012-01-27

2.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

3.  New mini dental implant attachments versus O-ring attachment after cyclic aging: Analysis of retention strength and gap space.

Authors:  Abdalbseet A Fatalla; Ke Song; Ying-Guang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-06-06

4.  A finite element analysis of stress distribution in the bone, around the implant supporting a mandibular overdenture with ball/o ring and magnetic attachment.

Authors:  Jins John; V Rangarajan; Ravindra C Savadi; K S Satheesh Kumar; Preeti Satheesh Kumar
Journal:  J Indian Prosthodont Soc       Date:  2012-03-09

Review 5.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

6.  The effect of inter-implant distance on retention and resistance to dislodging forces for mandibular implant-tissue-supported overdentures.

Authors:  Farhad Tabatabaian; Abolfazl Saboury; Zahra Sadat Sobhani; Vicki C Petropoulos
Journal:  J Dent (Tehran)       Date:  2014-09-30

7.  In vitro retention force measurement for three different attachment systems for implant-retained overdenture.

Authors:  Kareem Mohammed Reda; Ibrahim Ramadan El-Torky; Mohamed Nabeel El-Gendy
Journal:  J Indian Prosthodont Soc       Date:  2016 Oct-Dec

8.  Effect of Implant Location on Palateless Complete Overdenture Retention: an In Vitro Study.

Authors:  Nesma El-Amier; Ehab Elsaih; Mona Gibreel; Hassan El-Motaiam
Journal:  J Oral Maxillofac Res       Date:  2018-09-30

9.  Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures.

Authors:  Nesreen El Mekawy; Mohamed-Yosry Elhawary
Journal:  J Clin Exp Dent       Date:  2019-01-01

10.  The Effect of Denture Cleansing Solutions on the Retention of Precision Attachments: An In Vitro Study.

Authors:  Gonca Deste Gokay; Serhat Emre Ozkir; Thomas Gerhard Wolf; Gulsum Gokcimen; Nergiz Rona; Mehmet Bicer; Burak Yilmaz
Journal:  Int J Environ Res Public Health       Date:  2022-04-05       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.