Literature DB >> 23446044

Comparison of Kasai autocorrelation and maximum likelihood estimators for Doppler optical coherence tomography.

Aaron C Chan1, Edmund Y Lam, Vivek J Srinivasan.   

Abstract

In optical coherence tomography (OCT) and ultrasound, unbiased Doppler frequency estimators with low variance are desirable for blood velocity estimation. Hardware improvements in OCT mean that ever higher acquisition rates are possible, which should also, in principle, improve estimation performance. Paradoxically, however, the widely used Kasai autocorrelation estimator's performance worsens with increasing acquisition rate. We propose that parametric estimators based on accurate models of noise statistics can offer better performance. We derive a maximum likelihood estimator (MLE) based on a simple additive white Gaussian noise model, and show that it can outperform the Kasai autocorrelation estimator. In addition, we also derive the Cramer Rao lower bound (CRLB), and show that the variance of the MLE approaches the CRLB for moderate data lengths and noise levels. We note that the MLE performance improves with longer acquisition time, and remains constant or improves with higher acquisition rates. These qualities may make it a preferred technique as OCT imaging speed continues to improve. Finally, our work motivates the development of more general parametric estimators based on statistical models of decorrelation noise.

Entities:  

Mesh:

Year:  2013        PMID: 23446044      PMCID: PMC3745780          DOI: 10.1109/TMI.2013.2248163

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  19 in total

1.  A new clutter rejection algorithm for Doppler ultrasound.

Authors:  Guy Cloutier; Danmin Chen; Louis-Gilles Durand
Journal:  IEEE Trans Med Imaging       Date:  2003-04       Impact factor: 10.048

2.  Objective selection of high-frequency power Doppler wall filter cutoff velocity for regions of interest containing multiple small vessels.

Authors:  Stephen Z Pinter; James C Lacefield
Journal:  IEEE Trans Med Imaging       Date:  2010-03-15       Impact factor: 10.048

3.  High-resolution functional vascular assessment with ultrasound.

Authors:  Chih-Kuang Yeh; Katherine W Ferrara; Dustin E Kruse
Journal:  IEEE Trans Med Imaging       Date:  2004-10       Impact factor: 10.048

4.  Full motion and flow field recovery from echo Doppler data.

Authors:  Muthuvel Arigovindan; Michael Sühling; Christian Jansen; Patrick Hunziker; Michael Unser
Journal:  IEEE Trans Med Imaging       Date:  2007-01       Impact factor: 10.048

5.  Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media.

Authors:  Z Chen; T E Milner; D Dave; J S Nelson
Journal:  Opt Lett       Date:  1997-01-01       Impact factor: 3.776

6.  In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography.

Authors:  J A Izatt; M D Kulkarni; S Yazdanfar; J K Barton; A J Welch
Journal:  Opt Lett       Date:  1997-09-15       Impact factor: 3.776

7.  Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation.

Authors:  Maciej Wojtkowski; Vivek Srinivasan; Tony Ko; James Fujimoto; Andrzej Kowalczyk; Jay Duker
Journal:  Opt Express       Date:  2004-05-31       Impact factor: 3.894

8.  Ultra-high-speed volumetric tomography of human retinal blood flow.

Authors:  Tilman Schmoll; Christoph Kolbitsch; Rainer A Leitgeb
Journal:  Opt Express       Date:  2009-03-02       Impact factor: 3.894

9.  Improved estimation of low velocities in color Doppler imaging by adapting the mean frequency estimator to the clutter rejection filter.

Authors:  A Herment; G Demoment; P Dumée
Journal:  IEEE Trans Biomed Eng       Date:  1996-09       Impact factor: 4.538

10.  Quantitative cerebral blood flow with optical coherence tomography.

Authors:  Vivek J Srinivasan; Sava Sakadzić; Iwona Gorczynska; Svetlana Ruvinskaya; Weicheng Wu; James G Fujimoto; David A Boas
Journal:  Opt Express       Date:  2010-02-01       Impact factor: 3.894

View more
  5 in total

1.  Clinical feasibility of optical coherence micro-elastography for imaging tumor margins in breast-conserving surgery.

Authors:  Wes M Allen; Ken Y Foo; Renate Zilkens; Kelsey M Kennedy; Qi Fang; Lixin Chin; Benjamin F Dessauvagie; Bruce Latham; Christobel M Saunders; Brendan F Kennedy
Journal:  Biomed Opt Express       Date:  2018-11-19       Impact factor: 3.732

2.  Doppler OCT clutter rejection using variance minimization and offset extrapolation.

Authors:  Adil Akif; Konrad Walek; Collin Polucha; Jonghwan Lee
Journal:  Biomed Opt Express       Date:  2018-10-10       Impact factor: 3.732

3.  Comparison of amplitude-decorrelation, speckle-variance and phase-variance OCT angiography methods for imaging the human retina and choroid.

Authors:  Iwona Gorczynska; Justin V Migacz; Robert J Zawadzki; Arlie G Capps; John S Werner
Journal:  Biomed Opt Express       Date:  2016-02-19       Impact factor: 3.732

4.  Simultaneous estimation of bidirectional particle flow and relative flux using MUSIC-OCT: phantom studies.

Authors:  Siavash Yousefi; Ruikang K Wang
Journal:  Phys Med Biol       Date:  2014-10-20       Impact factor: 3.609

5.  Wide-field quantitative micro-elastography of human breast tissue.

Authors:  Wes M Allen; Kelsey M Kennedy; Qi Fang; Lixin Chin; Andrea Curatolo; Lucinda Watts; Renate Zilkens; Synn Lynn Chin; Benjamin F Dessauvagie; Bruce Latham; Christobel M Saunders; Brendan F Kennedy
Journal:  Biomed Opt Express       Date:  2018-02-09       Impact factor: 3.732

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.