Literature DB >> 23445093

Nocturnal glucose control with an artificial pancreas at a diabetes camp.

Moshe Phillip1, Tadej Battelino, Eran Atlas, Olga Kordonouri, Natasa Bratina, Shahar Miller, Torben Biester, Magdalena Avbelj Stefanija, Ido Muller, Revital Nimri, Thomas Danne.   

Abstract

BACKGROUND: Recent studies have shown that an artificial-pancreas system can improve glucose control and reduce nocturnal hypoglycemia. However, it is not known whether such results can be replicated in settings outside the hospital.
METHODS: In this multicenter, multinational, randomized, crossover trial, we assessed the short-term safety and efficacy of an artificial pancreas system for control of nocturnal glucose levels in patients (10 to 18 years of age) with type 1 diabetes at a diabetes camp. In two consecutive overnight sessions, we randomly assigned 56 patients to receive treatment with an artificial pancreas on the first night and a sensor-augmented insulin pump (control) on the second night or to the reverse order of therapies on the first and second nights. Thus, all the patients received each treatment in a randomly assigned order. The primary end points were the number of hypoglycemic events (defined as a sensor glucose value of <63 mg per deciliter [3.5 mmol per liter] for at least 10 consecutive minutes), the time spent with glucose levels below 60 mg per deciliter (3.3 mmol per liter), and the mean overnight glucose level for individual patients.
RESULTS: On nights when the artificial pancreas was used, versus nights when the sensor-augmented insulin pump was used, there were significantly fewer episodes of nighttime glucose levels below 63 mg per deciliter (7 vs. 22) and significantly shorter periods when glucose levels were below 60 mg per deciliter (P=0.003 and P=0.02, respectively, after adjustment for multiplicity). Median values for the individual mean overnight glucose levels were 126.4 mg per deciliter (interquartile range, 115.7 to 139.1 [7.0 mmol per liter; interquartile range, 6.4 to 7.7]) with the artificial pancreas and 140.4 mg per deciliter (interquartile range, 105.7 to 167.4 [7.8 mmol per liter; interquartile range, 5.9 to 9.3]) with the sensor-augmented pump. No serious adverse events were reported.
CONCLUSIONS: Patients at a diabetes camp who were treated with an artificial-pancreas system had less nocturnal hypoglycemia and tighter glucose control than when they were treated with a sensor-augmented insulin pump. (Funded by Sanofi and others; ClinicalTrials.gov number, NCT01238406.).

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23445093     DOI: 10.1056/NEJMoa1206881

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  140 in total

1.  Stress Testing of an Artificial Pancreas System With Pizza and Exercise Leads to Improvements in the System's Fuzzy Logic Controller.

Authors:  Richard Mauseth; Sandra M Lord; Irl B Hirsch; Robert C Kircher; Don P Matheson; Carla J Greenbaum
Journal:  J Diabetes Sci Technol       Date:  2015-09-14

Review 2.  AP@home: The Artificial Pancreas Is Now at Home.

Authors:  Lutz Heinemann; Carsten Benesch; J Hans DeVries
Journal:  J Diabetes Sci Technol       Date:  2016-06-28

3.  Report from IPITA-TTS Opinion Leaders Meeting on the Future of β-Cell Replacement.

Authors:  Stephen T Bartlett; James F Markmann; Paul Johnson; Olle Korsgren; Bernhard J Hering; David Scharp; Thomas W H Kay; Jonathan Bromberg; Jon S Odorico; Gordon C Weir; Nancy Bridges; Raja Kandaswamy; Peter Stock; Peter Friend; Mitsukazu Gotoh; David K C Cooper; Chung-Gyu Park; Phillip OʼConnell; Cherie Stabler; Shinichi Matsumoto; Barbara Ludwig; Pratik Choudhary; Boris Kovatchev; Michael R Rickels; Megan Sykes; Kathryn Wood; Kristy Kraemer; Albert Hwa; Edward Stanley; Camillo Ricordi; Mark Zimmerman; Julia Greenstein; Eduard Montanya; Timo Otonkoski
Journal:  Transplantation       Date:  2016-02       Impact factor: 4.939

4.  Combining glucose monitoring and insulin delivery into a single device: current progress and ongoing challenges of the artificial pancreas.

Authors:  Kathleen H Ang; William V Tamborlane; Stuart A Weinzimer
Journal:  Expert Opin Drug Deliv       Date:  2015-09-07       Impact factor: 6.648

5.  Preliminary evaluation of a new semi-closed-loop insulin therapy system over the prandial period in adult patients with type 1 diabetes: the WP6.0 Diabeloop study.

Authors:  Marie Aude Quemerais; Maeva Doron; Florent Dutrech; Vincent Melki; Sylvia Franc; Michel Antonakios; Guillaume Charpentier; Helene Hanaire; Pierre Yves Benhamou
Journal:  J Diabetes Sci Technol       Date:  2014-08-04

6.  Patient Perception and Satisfaction With Insulin Pump System: Pilot User Experience Survey.

Authors:  Maria Adela Grando; Mike Bayuk; George Karway; Krystal Corrette; Danielle Groat; Curtiss B Cook; Bithika Thompson
Journal:  J Diabetes Sci Technol       Date:  2019-05-05

Review 7.  Technology to optimize pediatric diabetes management and outcomes.

Authors:  Jessica T Markowitz; Kara R Harrington; Lori M B Laffel
Journal:  Curr Diab Rep       Date:  2013-12       Impact factor: 4.810

8.  Periodic zone-MPC with asymmetric costs for outpatient-ready safety of an artificial pancreas to treat type 1 diabetes.

Authors:  Ravi Gondhalekar; Eyal Dassau; Francis J Doyle
Journal:  Automatica (Oxf)       Date:  2016-06-01       Impact factor: 5.944

9.  Outpatient glycemic control with a bionic pancreas in type 1 diabetes.

Authors:  Steven J Russell; Firas H El-Khatib; Manasi Sinha; Kendra L Magyar; Katherine McKeon; Laura G Goergen; Courtney Balliro; Mallory A Hillard; David M Nathan; Edward R Damiano
Journal:  N Engl J Med       Date:  2014-06-15       Impact factor: 91.245

10.  Enhanced Model Predictive Control (eMPC) Strategy for Automated Glucose Control.

Authors:  Joon Bok Lee; Eyal Dassau; Ravi Gondhalekar; Dale E Seborg; Jordan E Pinsker; Francis J Doyle
Journal:  Ind Eng Chem Res       Date:  2016-10-27       Impact factor: 3.720

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.