Literature DB >> 27942106

Enhanced Model Predictive Control (eMPC) Strategy for Automated Glucose Control.

Joon Bok Lee1, Eyal Dassau1, Ravi Gondhalekar2, Dale E Seborg3, Jordan E Pinsker4, Francis J Doyle1.   

Abstract

Development of an effective artificial pancreas (AP) controller to deliver insulin autonomously to people with type 1 diabetes mellitus is a difficult task. In this paper, three enhancements to a clinically validated AP model predictive controller (MPC) are proposed that address major challenges facing automated blood glucose control, and are then evaluated by both in silico tests and clinical trials. First, the core model of insulin-blood glucose dynamics utilized in the MPC is expanded with a medically inspired personalization scheme to improve controller responses in the face of inter- and intra-individual variations in insulin sensitivity. Next, the asymmetric nature of the short-term consequences of hypoglycemia versus hyperglycemia is incorporated in an asymmetric weighting of the MPC cost function. Finally, an enhanced dynamic insulin-on-board algorithm is proposed to minimize the likelihood of controller-induced hypoglycemia following a rapid rise of blood glucose due to rescue carbohydrate load with accompanying insulin suspension. Each advancement is evaluated separately and in unison through in silico trials based on a new clinical protocol, which incorporates induced hyper- and hypoglycemia to test robustness. The advancements are also evaluated in an advisory mode (simulated) testing of clinical data. The combination of the three proposed advancements show statistically significantly improved performance over the nonpersonalized controller without any enhancements across all metrics, displaying increased time in the 70-180 mg/dL safe glycemic range (76.9 versus 68.8%) and the 80-140 mg/dL euglycemic range (48.1 versus 44.5%), without a statistically significant increase in instances of hypoglycemia. The proposed advancements provide safe control action for AP applications, personalizing and improving controller performance without the need for extensive model identification processes.

Entities:  

Year:  2016        PMID: 27942106      PMCID: PMC5144164          DOI: 10.1021/acs.iecr.6b02718

Source DB:  PubMed          Journal:  Ind Eng Chem Res        ISSN: 0888-5885            Impact factor:   3.720


  35 in total

1.  Day and Night Closed-Loop Control Using the Integrated Medtronic Hybrid Closed-Loop System in Type 1 Diabetes at Diabetes Camp.

Authors:  Trang T Ly; Anirban Roy; Benyamin Grosman; John Shin; Alex Campbell; Salman Monirabbasi; Bradley Liang; Rie von Eyben; Satya Shanmugham; Paula Clinton; Bruce A Buckingham
Journal:  Diabetes Care       Date:  2015-06-06       Impact factor: 19.112

2.  2 month evening and night closed-loop glucose control in patients with type 1 diabetes under free-living conditions: a randomised crossover trial.

Authors:  Jort Kropff; Simone Del Favero; Jerome Place; Chiara Toffanin; Roberto Visentin; Marco Monaro; Mirko Messori; Federico Di Palma; Giordano Lanzola; Anne Farret; Federico Boscari; Silvia Galasso; Paolo Magni; Angelo Avogaro; Patrick Keith-Hynes; Boris P Kovatchev; Daniela Bruttomesso; Claudio Cobelli; J Hans DeVries; Eric Renard; Lalo Magni
Journal:  Lancet Diabetes Endocrinol       Date:  2015-09-30       Impact factor: 32.069

3.  Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial.

Authors:  Ahmad Haidar; Laurent Legault; Virginie Messier; Tina Maria Mitre; Catherine Leroux; Rémi Rabasa-Lhoret
Journal:  Lancet Diabetes Endocrinol       Date:  2014-11-27       Impact factor: 32.069

4.  Periodic zone-MPC with asymmetric costs for outpatient-ready safety of an artificial pancreas to treat type 1 diabetes.

Authors:  Ravi Gondhalekar; Eyal Dassau; Francis J Doyle
Journal:  Automatica (Oxf)       Date:  2016-06-01       Impact factor: 5.944

5.  Outpatient glycemic control with a bionic pancreas in type 1 diabetes.

Authors:  Steven J Russell; Firas H El-Khatib; Manasi Sinha; Kendra L Magyar; Katherine McKeon; Laura G Goergen; Courtney Balliro; Mallory A Hillard; David M Nathan; Edward R Damiano
Journal:  N Engl J Med       Date:  2014-06-15       Impact factor: 91.245

6.  Feasibility of Outpatient 24-Hour Closed-Loop Insulin Delivery.

Authors:  Martin I de Bock; Anirban Roy; Matthew N Cooper; Julie A Dart; Carolyn L Berthold; Adam J Retterath; Kate E Freeman; Benyamin Grosman; Natalie Kurtz; Fran Kaufman; Timothy W Jones; Elizabeth A Davis
Journal:  Diabetes Care       Date:  2015-08-27       Impact factor: 19.112

7.  Quantitative estimation of insulin sensitivity in type 1 diabetic subjects wearing a sensor-augmented insulin pump.

Authors:  Michele Schiavon; Chiara Dalla Man; Yogish C Kudva; Ananda Basu; Claudio Cobelli
Journal:  Diabetes Care       Date:  2013-12-06       Impact factor: 19.112

8.  Clinical evaluation of a personalized artificial pancreas.

Authors:  Eyal Dassau; Howard Zisser; Rebecca A Harvey; Matthew W Percival; Benyamin Grosman; Wendy Bevier; Eran Atlas; Shahar Miller; Revital Nimri; Lois Jovanovic; Francis J Doyle
Journal:  Diabetes Care       Date:  2012-11-27       Impact factor: 19.112

9.  Overnight glucose control with an automated, unified safety system in children and adolescents with type 1 diabetes at diabetes camp.

Authors:  Trang T Ly; Marc D Breton; Patrick Keith-Hynes; Daniel De Salvo; Paula Clinton; Kari Benassi; Benton Mize; Daniel Chernavvsky; Jéróme Place; Darrell M Wilson; Boris P Kovatchev; Bruce A Buckingham
Journal:  Diabetes Care       Date:  2014-05-30       Impact factor: 19.112

10.  Safety, efficacy and glucose turnover of reduced prandial boluses during closed-loop therapy in adolescents with type 1 diabetes: a randomized clinical trial.

Authors:  D Elleri; M Biagioni; J M Allen; K Kumareswaran; L Leelarathna; K Caldwell; M Nodale; M E Wilinska; A Haidar; P Calhoun; C Kollman; N C Jackson; A M Umpleby; C L Acerini; D B Dunger; R Hovorka
Journal:  Diabetes Obes Metab       Date:  2015-10-09       Impact factor: 6.577

View more
  12 in total

1.  Evaluation of an Artificial Pancreas with Enhanced Model Predictive Control and a Glucose Prediction Trust Index with Unannounced Exercise.

Authors:  Jordan E Pinsker; Alejandro J Laguna Sanz; Joon Bok Lee; Mei Mei Church; Camille Andre; Laura E Lindsey; Francis J Doyle; Eyal Dassau
Journal:  Diabetes Technol Ther       Date:  2018-07       Impact factor: 6.118

2.  Feasibility study of portable microwave microstrip open-loop resonator for non-invasive blood glucose level sensing: proof of concept.

Authors:  Carlos G Juan; Héctor García; Ernesto Ávila-Navarro; Enrique Bronchalo; Vicente Galiano; Óscar Moreno; Domingo Orozco; José María Sabater-Navarro
Journal:  Med Biol Eng Comput       Date:  2019-08-31       Impact factor: 2.602

3.  Plasma-Insulin-Cognizant Adaptive Model Predictive Control for Artificial Pancreas Systems.

Authors:  Iman Hajizadeh; Mudassir Rashid; Ali Cinar
Journal:  J Process Control       Date:  2019-04-10       Impact factor: 3.666

4.  Adaptive and Personalized Plasma Insulin Concentration Estimation for Artificial Pancreas Systems.

Authors:  Iman Hajizadeh; Mudassir Rashid; Sediqeh Samadi; Jianyuan Feng; Mert Sevil; Nicole Hobbs; Caterina Lazaro; Zacharie Maloney; Rachel Brandt; Xia Yu; Kamuran Turksoy; Elizabeth Littlejohn; Eda Cengiz; Ali Cinar
Journal:  J Diabetes Sci Technol       Date:  2018-03-23

5.  Event-Triggered Model Predictive Control for Embedded Artificial Pancreas Systems.

Authors:  Ankush Chakrabarty; Stamatina Zavitsanou; Francis J Doyle; Eyal Dassau
Journal:  IEEE Trans Biomed Eng       Date:  2017-05-23       Impact factor: 4.538

6.  Velocity-weighting & velocity-penalty MPC of an artificial pancreas: Improved safety & performance.

Authors:  Ravi Gondhalekar; Eyal Dassau; Francis J Doyle
Journal:  Automatica (Oxf)       Date:  2018-03-20       Impact factor: 5.944

7.  Adaptive Zone Model Predictive Control of Artificial Pancreas Based on Glucose- and Velocity-Dependent Control Penalties.

Authors:  Dawei Shi; Eyal Dassau; Francis J Doyle
Journal:  IEEE Trans Biomed Eng       Date:  2018-08-21       Impact factor: 4.538

8.  Performance Analysis of Different Embedded Systems and Open-Source Optimization Packages Towards an Impulsive MPC Artificial Pancreas.

Authors:  Jhon E Goez-Mora; María F Villa-Tamayo; Monica Vallejo; Pablo S Rivadeneira
Journal:  Front Endocrinol (Lausanne)       Date:  2021-04-26       Impact factor: 5.555

9.  First Outpatient Evaluation of a Tubeless Automated Insulin Delivery System with Customizable Glucose Targets in Children and Adults with Type 1 Diabetes.

Authors:  Gregory P Forlenza; Bruce A Buckingham; Sue A Brown; Bruce W Bode; Carol J Levy; Amy B Criego; R Paul Wadwa; Erin C Cobry; Robert J Slover; Laurel H Messer; Cari Berget; Susan McCoy; Laya Ekhlaspour; Ryan S Kingman; Mary K Voelmle; Jennifer Boyd; Grenye O'Malley; Aimee Grieme; Kaisa Kivilaid; Krista Kleve; Bonnie Dumais; Todd Vienneau; Lauren M Huyett; Joon Bok Lee; Jason O'Connor; Eric Benjamin; Trang T Ly
Journal:  Diabetes Technol Ther       Date:  2021-01-18       Impact factor: 6.118

10.  Safety and Feasibility of the OmniPod Hybrid Closed-Loop System in Adult, Adolescent, and Pediatric Patients with Type 1 Diabetes Using a Personalized Model Predictive Control Algorithm.

Authors:  Bruce A Buckingham; Gregory P Forlenza; Jordan E Pinsker; Mark P Christiansen; R Paul Wadwa; Jennifer Schneider; Thomas A Peyser; Eyal Dassau; Joon Bok Lee; Jason O'Connor; Jennifer E Layne; Trang T Ly
Journal:  Diabetes Technol Ther       Date:  2018-02-12       Impact factor: 6.118

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.