Literature DB >> 23439180

In silico evaluation of an artificial pancreas combining exogenous ultrafast-acting technosphere insulin with zone model predictive control.

Justin J Lee1, Eyal Dassau, Howard Zisser, Rebecca A Harvey, Lois Jovanovič, Francis J Doyle.   

Abstract

BACKGROUND: Because of the slow pharmacokinetics of subcutaneous (SC) insulin, avoiding postprandial hyperglycemia has been a major challenge for an artificial pancreas (AP) using SC insulin without a meal announcement.
METHODS: A semiautomated AP with Technosphere® Insulin (TI; MannKind Corporation, Valencia, CA) was designed to combine pulmonary and SC insulin. Manual inhalation of 10 U ultrafast-absorbing TI at mealtime delivers the first, or cephalic, phase of insulin, and an SC insulin pump controlled by zone model predictive controller delivers second-phase and basal insulin. This AP design was evaluated on 100 in silico subjects from the University of Virginia/Padova metabolic simulator using a protocol of two 50 g carbohydrate (CHO) meals and two 15 g CHO snacks.
RESULTS: Simulation analysis shows that the semiautomated AP with TI provides 32% and 16% more time in the controller target zone (80-140 mg/dl) during the 4 h postprandial period, with 39 and 20 mg/dl lower postprandial blood glucose peak on average than the pure feedback AP and the AP with manual feed-forward SC bolus, respectively. No severe hypoglycemia (<50 mg/dl) was observed in any cases.
CONCLUSIONS: The semiautomated AP with TI provides maximum time in the clinically accepted region when compared with pure feedback AP and AP with manual feed-forward SC bolus. Furthermore, the semiautomated AP with TI provides a flexible operation (optional TI inhalation) with minimal user interaction, where the controller design can be tailored to specific user needs and abilities to interact with the device.
© 2012 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23439180      PMCID: PMC3692236          DOI: 10.1177/193229681300700127

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  34 in total

1.  Suspended insulin infusion during overnight closed-loop glucose control in children and adolescents with Type 1 diabetes.

Authors:  D Elleri; J M Allen; M Nodale; M E Wilinska; C L Acerini; D B Dunger; R Hovorka
Journal:  Diabet Med       Date:  2010-04       Impact factor: 4.359

2.  Hospital glucose control: safe and reliable glycemic control using enhanced model predictive control algorithm in medical intensive care unit patients.

Authors:  Karin Amrein; Martin Ellmerer; Roman Hovorka; Norman Kachel; Dieter Parcz; Stefan Korsatko; Karlheinz Smolle; Sabine Perl; Gerlies Bock; Werner Doll; Gerd Köhler; Thomas R Pieber; Johannes Plank
Journal:  Diabetes Technol Ther       Date:  2010-05       Impact factor: 6.118

3.  Multinational study of subcutaneous model-predictive closed-loop control in type 1 diabetes mellitus: summary of the results.

Authors:  Boris Kovatchev; Claudio Cobelli; Eric Renard; Stacey Anderson; Marc Breton; Stephen Patek; William Clarke; Daniela Bruttomesso; Alberto Maran; Silvana Costa; Angelo Avogaro; Chiara Dalla Man; Andrea Facchinetti; Lalo Magni; Giuseppe De Nicolao; Jerome Place; Anne Farret
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

4.  A bihormonal closed-loop artificial pancreas for type 1 diabetes.

Authors:  Firas H El-Khatib; Steven J Russell; David M Nathan; Robert G Sutherlin; Edward R Damiano
Journal:  Sci Transl Med       Date:  2010-04-14       Impact factor: 17.956

Review 5.  Glucose clamp algorithms and insulin time-action profiles.

Authors:  B Wayne Bequette
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

6.  Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: the Virginia experience.

Authors:  William L Clarke; Stacey Anderson; Marc Breton; Stephen Patek; Laurissa Kashmer; Boris Kovatchev
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

7.  Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial.

Authors:  Roman Hovorka; Janet M Allen; Daniela Elleri; Ludovic J Chassin; Julie Harris; Dongyuan Xing; Craig Kollman; Tomas Hovorka; Anne Mette F Larsen; Marianna Nodale; Alessandra De Palma; Malgorzata E Wilinska; Carlo L Acerini; David B Dunger
Journal:  Lancet       Date:  2010-02-04       Impact factor: 79.321

8.  Zone model predictive control: a strategy to minimize hyper- and hypoglycemic events.

Authors:  Benyamin Grosman; Eyal Dassau; Howard C Zisser; Lois Jovanovic; Francis J Doyle
Journal:  J Diabetes Sci Technol       Date:  2010-07-01

9.  MD-logic artificial pancreas system: a pilot study in adults with type 1 diabetes.

Authors:  Eran Atlas; Revital Nimri; Shahar Miller; Eli A Grunberg; Moshe Phillip
Journal:  Diabetes Care       Date:  2010-02-11       Impact factor: 19.112

10.  Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies.

Authors:  Roman Hovorka; Kavita Kumareswaran; Julie Harris; Janet M Allen; Daniela Elleri; Dongyuan Xing; Craig Kollman; Marianna Nodale; Helen R Murphy; David B Dunger; Stephanie A Amiel; Simon R Heller; Malgorzata E Wilinska; Mark L Evans
Journal:  BMJ       Date:  2011-04-13
View more
  2 in total

1.  Clinical results of an automated artificial pancreas using technosphere inhaled insulin to mimic first-phase insulin secretion.

Authors:  Howard Zisser; Eyal Dassau; Justin J Lee; Rebecca A Harvey; Wendy Bevier; Francis J Doyle
Journal:  J Diabetes Sci Technol       Date:  2015-04-21

2.  Robust multi-objective blood glucose control in Type-1 diabetic patient.

Authors:  Sharmistha Mandal; Ashoke Sutradhar
Journal:  IET Syst Biol       Date:  2019-06       Impact factor: 1.615

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.