AIM: To compare the performance characteristics of Pentax HiLine (PHL) (with i-scan) and Olympus Lucera (OL) systems in a screening population.
METHODS: Screening colonoscopies in asymptomatic guaiac faecal occult blood test-positive patients with PHL (n = 58) and OL (n = 425) colonoscopes were analysed. All procedures were performed by a single colonoscopist. PHL used white-light endoscopy (WLE) on scope insertion and contrast/surface enhancement (i-scan 1) on withdrawal, and OL utilised WLE both on insertion and withdrawal. Patient age, sex, instrument insertion and withdrawal times, nurse assessed patient comfort scores, midazolam and fentanyl doses, procedure completion and rates of lesion detection were recorded separately for each group. Comparisons between the groups were made using either Fisher's exact test (for dichotomous variables) or Mann-Whitney U test (for ordinal and continuous variables).
RESULTS: Colonoscopy completion rates were similar in both groups: 413/425 (97.2%) for OL and 55/58 (94.9%) for PHL (P = 0.24). For complete colonoscopies, the two groups were well matched for age, sex, colonoscope insertion times (mean 11.1 min in OL vs 11.6 min in PHL, P = 0.93) and normal colonoscopy withdrawal times (mean 15.6 min in OL vs 14.7 min in PHL, P = 0.2). Patients in the PHL group experienced a small increase in discomfort (mean patient comfort scores were 0.49 in the OL and 0.95 in the PHL group, P < 0.0001). While Fentanyl doses required were similar between groups (mean 57.5 μg in OL vs 61.4 μg in PHL, P = 0.13), slightly more Midazolam was required in the PHL group (mean 2.1 mg in OL vs 2.4 mg in PHL, P = 0.035). There was no difference in polyp (58% in OL vs 67% in PHL) or adenoma (49% in OL vs 56% in PHL) detection rates between the groups. Neither the total number of polyps and adenomas, nor the characteristics of these (including size, location or presence of advanced features) were different between the two systems.
CONCLUSION: This study suggests that there is no advantage of either colonoscope system in lesion detection.

Entities:  

Keywords:  Adenoma; Colonoscopy; Pentax HiLine; Polyp; i-scan

Year:  2013        PMID: 23424182      PMCID: PMC3574614          DOI: 10.4253/wjge.v5.i2.62

Source DB:  PubMed          Journal:  World J Gastrointest Endosc


  17 in total

1.  Risk of developing proximal versus distal colorectal cancer after a negative colonoscopy: a population-based study.

Authors:  Josh Lakoff; Lawrence F Paszat; Refik Saskin; Linda Rabeneck
Journal:  Clin Gastroenterol Hepatol       Date:  2008-08-08       Impact factor: 11.382

Review 2.  Novel image-enhanced endoscopy with i-scan technology.

Authors:  Shinya Kodashima; Mitsuhiro Fujishiro
Journal:  World J Gastroenterol       Date:  2010-03-07       Impact factor: 5.742

3.  Cap-fitted colonoscopy: a randomized, tandem colonoscopy study of adenoma miss rates.

Authors:  David G Hewett; Douglas K Rex
Journal:  Gastrointest Endosc       Date:  2010-06-25       Impact factor: 9.427

4.  Colorectal cancers detected after colonoscopy frequently result from missed lesions.

Authors:  Heiko Pohl; Douglas J Robertson
Journal:  Clin Gastroenterol Hepatol       Date:  2010-07-22       Impact factor: 11.382

5.  Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies.

Authors:  D K Rex; C S Cutler; G T Lemmel; E Y Rahmani; D W Clark; D J Helper; G A Lehman; D G Mark
Journal:  Gastroenterology       Date:  1997-01       Impact factor: 22.682

6.  The reduction in colorectal cancer mortality after colonoscopy varies by site of the cancer.

Authors:  Harminder Singh; Zoann Nugent; Alain A Demers; Erich V Kliewer; Salaheddin M Mahmud; Charles N Bernstein
Journal:  Gastroenterology       Date:  2010-06-20       Impact factor: 22.682

7.  High definition colonoscopy combined with i-Scan is superior in the detection of colorectal neoplasias compared with standard video colonoscopy: a prospective randomized controlled trial.

Authors:  A Hoffman; F Sar; M Goetz; A Tresch; J Mudter; S Biesterfeld; P R Galle; M F Neurath; R Kiesslich
Journal:  Endoscopy       Date:  2010-08-27       Impact factor: 10.093

8.  Dynamic patient position changes during colonoscope withdrawal increase adenoma detection: a randomized, crossover trial.

Authors:  James E East; Paul Bassett; Naila Arebi; Siwan Thomas-Gibson; Thomas Guenther; Brian P Saunders
Journal:  Gastrointest Endosc       Date:  2010-10-15       Impact factor: 9.427

9.  Association of colonoscopy and death from colorectal cancer.

Authors:  Nancy N Baxter; Meredith A Goldwasser; Lawrence F Paszat; Refik Saskin; David R Urbach; Linda Rabeneck
Journal:  Ann Intern Med       Date:  2008-12-15       Impact factor: 25.391

10.  Randomized comparison of surveillance intervals after colonoscopic removal of newly diagnosed adenomatous polyps. The National Polyp Study Workgroup.

Authors:  S J Winawer; A G Zauber; M J O'Brien; M N Ho; L Gottlieb; S S Sternberg; J D Waye; J Bond; M Schapiro; E T Stewart
Journal:  N Engl J Med       Date:  1993-04-01       Impact factor: 91.245

View more
  3 in total

1.  Does i-scan improve adenoma detection rate compared to high-definition colonoscopy? A systematic review and meta-analysis.

Authors:  Muhammad Aziz; Zohaib Ahmed; Hossein Haghbin; Asad Pervez; Hemant Goyal; Faisal Kamal; Abdallah Kobeissy; Ali Nawras; Douglas G Adler
Journal:  Endosc Int Open       Date:  2022-06-10

Review 2.  Value of screening endoscopy in evaluation of esophageal, gastric and colon cancers.

Authors:  Tae H Ro; Michelle A Mathew; Subhasis Misra
Journal:  World J Gastroenterol       Date:  2015-09-07       Impact factor: 5.742

3.  Multicentre randomised controlled trial comparing standard and high resolution optical technologies in colorectal cancer screening.

Authors:  Simona Di Caro; Lucia Fini; Roser Vega; Konstantinos C Fragkos; Sunil Dolwani; John Green; Lesley-Ann Smith; Conrad Beckett; Ewen Cameron; Matthew Banks
Journal:  Frontline Gastroenterol       Date:  2019-02-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.