Literature DB >> 23412184

Coronal malposition effects in total knee arthroplasty: a finite element analysis.

Gabriel Stan1, Horia Orban, Lucian Gruionu, Panait Gheorghe.   

Abstract

Prosthetic component malposition is not infrequent, because of technical flaws, especially without a computed navigation system. We assumed that an inclined interline of a prosthetic knee with components parallel in the coronal plane provides a better load distribution and lower contact pressure towards a varus malalignment. For that we studied, using finite element analysis, load intensity and distribution for three situations: ideal alignment of prosthetic components, tibial varus malposition of 3° and 8° leading to tibio-femoral varus malalignment (i.e. an unbalanced knee) and the same tibial varus malpositions, but with the femoral component also malpositioned in the coronal plane, so that they are parallel, and with equally tightened collateral ligaments (i.e. a balanced knee). We found that maximum contact pressure and underlying bone compression forces are higher for a balanced knee with an inclined interline than in ideal alignment, but lower than in an unbalanced knee. According to our results, 2- and 4-mm additional medial plateau resection on a proper balanced knee does not significantly affect the load distribution towards ideal alignment. Balancing is a key factor for prosthetic survival in cases when a certain degree of coronal malposition cannot be avoided.

Entities:  

Mesh:

Year:  2012        PMID: 23412184     DOI: 10.1007/s00590-012-1051-7

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  19 in total

1.  Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty.

Authors:  J Novotny; M H Gonzalez; F M Amirouche; Y C Li
Journal:  J Arthroplasty       Date:  2001-08       Impact factor: 4.757

2.  Using the transepicondylar axis to define the sagittal morphology of the distal part of the femur.

Authors:  J David Blaha; Corrie A Mancinelli; William H Simons
Journal:  J Bone Joint Surg Am       Date:  2002       Impact factor: 5.284

3.  A new method to investigate in vivo knee behavior using a finite element model of the lower limb.

Authors:  P Beillas; G Papaioannou; S Tashman; K H Yang
Journal:  J Biomech       Date:  2004-07       Impact factor: 2.712

4.  The effect of valgus/varus malalignment on load distribution in total knee replacements.

Authors:  Frederick W Werner; David C Ayers; Lorin P Maletsky; Paul J Rullkoetter
Journal:  J Biomech       Date:  2005-02       Impact factor: 2.712

5.  Effect of ultra-high molecular weight polyethylene thickness on contact mechanics in total knee replacement.

Authors:  M El-Deen; M García-Fiñana; Z M Jin
Journal:  Proc Inst Mech Eng H       Date:  2006-10       Impact factor: 1.617

6.  Polyethylene wear and variations in knee kinematics.

Authors:  D D D'Lima; J C Hermida; P C Chen; C W Colwell
Journal:  Clin Orthop Relat Res       Date:  2001-11       Impact factor: 4.176

7.  The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement.

Authors:  D L Bartel; V L Bicknell; T M Wright
Journal:  J Bone Joint Surg Am       Date:  1986-09       Impact factor: 5.284

8.  Intramedullary versus extramedullary femoral alignment systems in total knee replacement.

Authors:  H E Cates; M A Ritter; E M Keating; P M Faris
Journal:  Clin Orthop Relat Res       Date:  1993-01       Impact factor: 4.176

9.  Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations.

Authors:  J H Bargren; J D Blaha; M A Freeman
Journal:  Clin Orthop Relat Res       Date:  1983-03       Impact factor: 4.176

10.  Effect of rotation on the axial alignment of the femur. Pitfalls in the use of femoral intramedullary guides in total knee arthroplasty.

Authors:  C C Jiang; J N Insall
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

View more
  3 in total

1.  The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty.

Authors:  Seyyed Morteza Kazemi; Tooraj Shafaghi; Reza Minaei; Reza Osanloo; Hashem Abrishamkarzadeh; Farshad Safdari
Journal:  Arch Bone Jt Surg       Date:  2017-07

2.  An optimization method for implantation parameters of individualized TKA tibial prosthesis based on finite element analysis and orthogonal experimental design.

Authors:  Yuefu Dong; Zhen Zhang; Wanpeng Dong; Guanghong Hu; Bing Wang; Zhifang Mou
Journal:  BMC Musculoskelet Disord       Date:  2020-03-12       Impact factor: 2.362

3.  Kinematic Alignment in Total Knee Arthroplasty Reduces Polyethylene Contact Pressure by Increasing the Contact Area, When Compared to Mechanical Alignment-A Finite Element Analysis.

Authors:  Antonio Klasan; Andreas Kapshammer; Veronika Miron; Zoltan Major
Journal:  J Pers Med       Date:  2022-08-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.