Literature DB >> 11716373

Polyethylene wear and variations in knee kinematics.

D D D'Lima1, J C Hermida, P C Chen, C W Colwell.   

Abstract

A six-station knee wear simulator was used to test a posterior cruciate-retaining total knee arthroplasty design. Six implants each were tested in three groups; low intensity, high intensity, and malalignment using kinematic inputs from normal gait data, more severe loading conditions, and 3 degrees varus malalignment, respectively. For each group, gravimetric wear of the polyethylene inserts was measured for 5,000,000 cycles. Knee wear testing showed significantly different results for the three groups. Low intensity group inserts had mean wear rates of 3.1 (+/- 1.2) mg per million cycles. High intensity group inserts had significantly higher mean wear rates of 7.4 (+/- 2.7) mg per million cycles. Malalignment group inserts had the highest wear rates of 9.2 (+/- 3.3) mg per million cycles. The wear generated in the knee simulator seems to be dependent on the relative motions and loads at the articulating surface. The high intensity groups were subjected to motions that included reciprocating anteroposterior translations and a higher peak axial load than the low intensity group. This resulted in increasing the amount of wear. Varus malalignment also increased the total wear significantly. These results may explain some of the wide variations in wear seen in retrieved knee implants.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11716373     DOI: 10.1097/00003086-200111000-00015

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  32 in total

1.  The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty.

Authors:  R E da Assunção; N J Hancock; W J M Bruce; P Walker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-23       Impact factor: 4.342

2.  The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.

Authors:  Colin R Smith; Michael F Vignos; Rachel L Lenhart; Jarred Kaiser; Darryl G Thelen
Journal:  J Biomech Eng       Date:  2016-02       Impact factor: 2.097

3.  Intraoperative evaluation of total knee replacement: kinematic assessment with a navigation system.

Authors:  Daniela Casino; Stefano Zaffagnini; Sandra Martelli; Nicola Lopomo; Simone Bignozzi; Francesco Iacono; Alessandro Russo; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-12-20       Impact factor: 4.342

4.  Experimental testing of total knee replacements with UHMW-PE inserts: impact of severe wear test conditions.

Authors:  Carmen Zietz; Joern Reinders; Jens Schwiesau; Alexander Paulus; Jan Philippe Kretzer; Thomas Grupp; Sandra Utzschneider; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2015-02-26       Impact factor: 3.896

5.  Coronal malposition effects in total knee arthroplasty: a finite element analysis.

Authors:  Gabriel Stan; Horia Orban; Lucian Gruionu; Panait Gheorghe
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-07-25

6.  Polyethylene Damage Increases With Varus Implant Alignment in Posterior-stabilized and Constrained Condylar Knee Arthroplasty.

Authors:  Zhichang Li; Christina I Esposito; Chelsea N Koch; Yuo-Yu Lee; Douglas E Padgett; Timothy M Wright
Journal:  Clin Orthop Relat Res       Date:  2017-08-18       Impact factor: 4.176

7.  Strain measurements of the tibial insert of a knee prosthesis using a knee motion simulator.

Authors:  Toshihiro Sera; Yuya Iwai; Takaharu Yamazaki; Tetsuya Tomita; Hideki Yoshikawa; Hisahi Naito; Takeshi Matsumoto; Masao Tanaka
Journal:  J Orthop       Date:  2017-08-09

8.  Mechanical, Anatomical, and Kinematic Axis in TKA: Concepts and Practical Applications.

Authors:  Jeffrey J Cherian; Bhaveen H Kapadia; Samik Banerjee; Julio J Jauregui; Kimona Issa; Michael A Mont
Journal:  Curr Rev Musculoskelet Med       Date:  2014-06

9.  Changes in hindfoot alignment after total knee arthroplasty in knee osteoarthritic patients with varus deformity.

Authors:  Woo-Shin Cho; Hun-Sik Cho; Seong-Eun Byun
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-08-16       Impact factor: 4.342

10.  Improved design decreases wear in total knee arthroplasty with varus malalignment.

Authors:  Kazutaka Nishikawa; Ken Okazaki; Shuichi Matsuda; Yasutaka Tashiro; Shinya Kawahara; Hiroyuki Nakahara; Shigetoshi Okamoto; Takeshi Shimoto; Hidehiko Higaki; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-16       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.