Literature DB >> 23403064

Comparison of methods to measure corneal power for intraocular lens power calculation using a rotating Scheimpflug camera.

Giacomo Savini1, Piero Barboni, Michele Carbonelli, Kenneth J Hoffer.   

Abstract

PURPOSE: To assess the accuracy of corneal power measurements provided by a Scheimpflug camera (Pentacam HR) for intraocular lens (IOL) power calculation in unoperated eyes and compare the results with those of simulated keratometry (SimK) performed with a Placido-disk corneal topographer (Keratron).
SETTING: Private practice.
DESIGN: Evaluation of diagnostic test.
METHODS: Eight Scheimpflug camera corneal power measurements were analyzed: (1) average K, (2) true net power calculated using the Gaussian optics formula, (3) total corneal refractive power at 2.0 mm calculated by ray tracing on a ring and (4) as the average of the zone inside the ring, (5) total corneal refractive power at 3.0 mm on a ring and (6) as the average of the zone inside the ring, (7) the equivalent K reading at 3.0 mm and (8) at 4.5 mm. The IOL power was calculated using the Hoffer Q, Holladay 1, and SRK/T formulas.
RESULTS: No statistically significant differences were observed between any corneal power measurements, including simulated K, in 41 consecutive patients. The latter showed slightly lower mean absolute errors with all 3 formulas (range 0.26 to 0.27 diopter [D]). The Scheimpflug camera gave the lowest median absolute errors with all formulas; that is, the 3.0 mm equivalent K reading with the Hoffer Q formula (0.18 D) and Holladay 1 formula (0.17 D) and the 2.0 mm total corneal refractive power ring with the SRK/T formula (0.18 D).
CONCLUSION: Corneal power measurements provided by the Scheimpflug camera and Placido disk corneal topographer displayed comparable accuracy in IOL power calculation.
Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23403064     DOI: 10.1016/j.jcrs.2012.11.022

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  15 in total

1.  Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation.

Authors:  Ahmet Kirgiz; Kurşat Atalay; Havva Kaldirim; Kubra Serefoglu Cabuk; Mehmet Orcun Akdemir; Muhittin Taskapili
Journal:  Int Ophthalmol       Date:  2016-09-01       Impact factor: 2.031

2.  Predictability of intraocular lens power calculation in eyes after phototherapeutic keratectomy.

Authors:  Ryo Yoneyama; Kazutaka Kamiya; Kei Iijima; Masahide Takahashi; Nobuyuki Shoji
Journal:  Jpn J Ophthalmol       Date:  2019-11-05       Impact factor: 2.447

3.  Repeatability of total Keratometry and standard Keratometry by the IOLMaster 700 and comparison to total corneal astigmatism by Scheimpflug imaging.

Authors:  Giacomo Savini; Leonardo Taroni; Domenico Schiano-Lomoriello; Kenneth J Hoffer
Journal:  Eye (Lond)       Date:  2020-11-02       Impact factor: 4.456

4.  Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power.

Authors:  James A Davison; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2015-08-19

5.  Accuracy of optical biometry combined with Placido disc corneal topography for intraocular lens power calculation.

Authors:  Giacomo Savini; Kenneth J Hoffer; Piero Barboni; Nicole Balducci; Domenico Schiano-Lomoriello; Pietro Ducoli
Journal:  PLoS One       Date:  2017-02-23       Impact factor: 3.240

6.  Corneal power changes with Scheimpflug rotating camera after hyperopic LASIK.

Authors:  Woong-Joo Whang; Young-Sik Yoo; Choun-Ki Joo
Journal:  Medicine (Baltimore)       Date:  2018-12       Impact factor: 1.817

7.  Comparison of Conventional Keratometry and Total Keratometry in Normal Eyes.

Authors:  Rie Hoshikawa; Kazutaka Kamiya; Fusako Fujimura; Nobuyuki Shoji
Journal:  Biomed Res Int       Date:  2020-04-13       Impact factor: 3.411

8.  Site of clear corneal incision in cataract surgery and its effects on surgically induced astigmatism.

Authors:  Junjie Piao; Choun-Ki Joo
Journal:  Sci Rep       Date:  2020-03-03       Impact factor: 4.379

9.  Scheimpflug analysis of corneal power changes after hyperopic small incision lenticule extraction.

Authors:  Dan Fu; Jianmin Shang; Xiaoyu Zhang; Lingling Niu; Tian Han; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2021-07-20       Impact factor: 2.209

Review 10.  Intraocular lens power calculation in eyes with previous corneal refractive surgery.

Authors:  Giacomo Savini; Kenneth J Hoffer
Journal:  Eye Vis (Lond)       Date:  2018-07-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.