Literature DB >> 23392428

Wireless amplified nuclear MR detector (WAND) for high-spatial-resolution MR imaging of internal organs: preclinical demonstration in a rodent model.

Chunqi Qian1, Xin Yu, Der-Yow Chen, Stephen Dodd, Nadia Bouraoud, Nikorn Pothayee, Yun Chen, Scott Beeman, Kevin Bennett, Joseph Murphy-Boesch, Alan Koretsky.   

Abstract

PURPOSE: To assess the feasibility of imaging deep-lying internal organs at high spatial resolution by imaging kidney glomeruli in a rodent model with use of a newly developed, wireless amplified nuclear magnetic resonance (MR) detector.
MATERIALS AND METHODS: This study was approved by the Animal Care and Use Committee at the National Institutes of Health/National Institute of Neurologic Disorder and Stroke. As a preclinical demonstration of this new detection technology, five different millimeter-scale wireless amplified nuclear MR detectors configured as double frequency resonators were chronically implanted on the medial surface of the kidney in five Sprague-Dawley rats for MR imaging at 11.7 T. Among these rats, two were administered gadopentetate dimeglumine to visualize renal tubules on T1-weighted gradient-refocused echo (GRE) images, two were administered cationized ferritin to visualize glomeruli on T2*-weighted GRE images, and the remaining rat was administered both gadopentetate dimeglumine and cationized ferritin to visualize the interleaved pattern of renal tubules and glomeruli. The image intensity in each pixel was compared with the local tissue signal intensity average to identify regions of hyper- or hypointensity.
RESULTS: T1-weighted images with 70-μm in-plane resolution and 200-μm section thickness were obtained within 3.2 minutes to image renal tubules, and T2*-weighted images of the same resolution were obtained within 5.8 minutes to image the glomeruli. Hyperintensity from gadopentetate dimeglumine enabled visualization of renal tubules, and hypointensity from cationic ferritin enabled visualization of the glomeruli.
CONCLUSION: High-spatial-resolution images have been obtained to observe kidney microstructures in vivo with a wireless amplified nuclear MR detector.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23392428      PMCID: PMC3689449          DOI: 10.1148/radiol.13121352

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  19 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  Sensitivity enhancement of remotely coupled NMR detectors using wirelessly powered parametric amplification.

Authors:  Chunqi Qian; Joseph Murphy-Boesch; Stephen Dodd; Alan Koretsky
Journal:  Magn Reson Med       Date:  2012-01-13       Impact factor: 4.668

3.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

4.  NMR imaging of catalytic hydrogenation in microreactors with the use of para-hydrogen.

Authors:  Louis-S Bouchard; Scott R Burt; M Sabieh Anwar; Kirill V Kovtunov; Igor V Koptyug; Alexander Pines
Journal:  Science       Date:  2008-01-25       Impact factor: 47.728

5.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

6.  Tuned fiducial markers to identify body locations with minimal perturbation of tissue magnetization.

Authors:  M Burl; G A Coutts; I R Young
Journal:  Magn Reson Med       Date:  1996-09       Impact factor: 4.668

7.  Prostate: MR imaging with an endorectal surface coil.

Authors:  M D Schnall; R E Lenkinski; H M Pollack; Y Imai; H Y Kressel
Journal:  Radiology       Date:  1989-08       Impact factor: 11.105

8.  Biological magnetic resonance imaging using laser-polarized 129Xe.

Authors:  M S Albert; G D Cates; B Driehuys; W Happer; B Saam; C S Springer; A Wishnia
Journal:  Nature       Date:  1994-07-21       Impact factor: 49.962

9.  Study of acute renal ischemia in the rat using magnetic resonance imaging and spectroscopy.

Authors:  F Terrier; F Lazeyras; S Posse; W P Aue; A Zimmermann; B M Frey; F J Frey
Journal:  Magn Reson Med       Date:  1989-10       Impact factor: 4.668

10.  MRI of the basement membrane using charged nanoparticles as contrast agents.

Authors:  Kevin M Bennett; Hua Zhou; James P Sumner; Stephen J Dodd; Nadia Bouraoud; Kent Doi; Robert A Star; Alan P Koretsky
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

View more
  25 in total

Review 1.  Why and how we determine nephron number.

Authors:  John F Bertram; Luise A Cullen-McEwen; Gary F Egan; Norbert Gretz; Edwin Baldelomar; Scott C Beeman; Kevin M Bennett
Journal:  Pediatr Nephrol       Date:  2014-04       Impact factor: 3.714

2.  A Novel Expandable Catheter Wireless Amplified NMR Detector for MR Sensitivity Accessing the Kidney in Rodent Model.

Authors:  Roshan Timilsina; Chunqi Qian
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-01-04       Impact factor: 3.833

Review 3.  MRI-detectable nanoparticles: the potential role in the diagnosis of and therapy for chronic kidney disease.

Authors:  Jennifer R Charlton; Scott C Beeman; Kevin M Bennett
Journal:  Adv Chronic Kidney Dis       Date:  2013-11       Impact factor: 3.620

4.  Parallel magnetic resonance image reconstruction from a single-element parametric amplifier.

Authors:  Roshan Timilsina; Chunqi Qian
Journal:  Magn Reson Imaging       Date:  2019-08-16       Impact factor: 2.546

5.  The emerging role of MRI in quantitative renal glomerular morphology.

Authors:  K M Bennett; John F Bertram; Scott C Beeman; Norbert Gretz
Journal:  Am J Physiol Renal Physiol       Date:  2013-03-20

6.  Live nephron imaging by MRI.

Authors:  Chunqi Qian; Xin Yu; Nikorn Pothayee; Stephen Dodd; Nadia Bouraoud; Robert Star; Kevin Bennett; Alan Koretsky
Journal:  Am J Physiol Renal Physiol       Date:  2014-09-03

Review 7.  MRI tools for assessment of microstructure and nephron function of the kidney.

Authors:  Luke Xie; Kevin M Bennett; Chunlei Liu; G Allan Johnson; Jeff Lei Zhang; Vivian S Lee
Journal:  Am J Physiol Renal Physiol       Date:  2016-09-14

8.  Mapping vascular and glomerular pathology in a rabbit model of neonatal acute kidney injury using MRI.

Authors:  Neda Parvin; Jennifer R Charlton; Edwin J Baldelomar; Jamal J Derakhshan; Kevin M Bennett
Journal:  Anat Rec (Hoboken)       Date:  2020-06-07       Impact factor: 2.064

Review 9.  Nephron number, hypertension, and CKD: physiological and genetic insight from humans and animal models.

Authors:  Xuexiang Wang; Michael R Garrett
Journal:  Physiol Genomics       Date:  2017-01-27       Impact factor: 3.107

10.  High-resolution MRI of kidney microstructures at 7.05 T with an endo-colonic Wireless Amplified NMR detector.

Authors:  Xianchun Zeng; Shuangtao Ma; John M Kruger; Rongpin Wang; Xiaobo Tan; Chunqi Qian
Journal:  J Magn Reson       Date:  2019-04-25       Impact factor: 2.229

View more